X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-115-21809

Well Details

Well ID: 34-115-21809
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Morgan Township
Operator Name: KUNTZ DAREL D
Well Pad ID:
Farm/Lease Name: ALLEN
License Status: Domestic Well
License Date: 1979-04-05
Spud Date: 1979-04-09
Spud Drilling Contractor:
Final Drill Date: 1979-04-13
Well Total Depth: 1613.00 ft
Configuration: Vertical
Latitude: 39.670000
Longitude: -81.860000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-04-05 383 NORAMCO INC GeoDate 4/5/79
Original Spud 1979-04-09
Completed 1979-04-13
Reached Total Depth 1979-04-13
CO 1994-12-15 5020 ALLEN RUSSELL & MARIE GeoDate 4/5/79
Change of Owner 2011-08-09 Operator changed from 5020, ALLEN RUSSELL & MARIE to 8838, KUNTZ DAREL D
Record Last Modified 2011-08-09

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1492 1550 12
1492 1550 12
1492 1550 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 40000 Gal 26000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 ALLEN RUSSELL & MARIE 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 ALLEN RUSSELL & MARIE Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-135459797 2016-12-29 0:00 PW No Violations 1.00
0135459797 2016-12-29 Production Wells No Violations The inspection today revealed that this well is surrounded by a privacy fence that is locked at both entry points. I tried to call Darel Kuntz using the number on RBDMS but this number has been disconnected. I was able to look over the fence a little bit to see a little bit of what was on the other side. This well is equipped with a pumping unit, a 4 1/2 inch diameter wellhead, 1 1/2 inch diameter production tubing, 2 inch production lines, and what appeared to be to gas regulators on the production lines. There is an electric box near the motor to provide electric to the motor on the pumping unit and appears to be hooked up to the motor and electric. The well appeared to have all valves open on the lines but I can not be sure. There are two tanks, a 100 barrel steel tank and a 50 barrel steel tank, and a vertical separator near the well. I stuck my camera over the fence and tried to get some photos as best I could of the well and tanks for my files. There appeared to be no issues at the time of inspection.
0149671105 2011-11-28 Production Wells No Violations Complaint received over the weekend from Dave Ball, regarding this well which is located in a housing development. The tank is located too close to the well. The fence has been taken down because they are installing a pumping unit on the well. I called Darel Kuntz and left a message that tank needs to be 50 from the well and I requested that the fence be re-installed.
1191753605 2007-10-05 Production Wells No Violations Inspected site at request of Darrel Koonce,he wanted to become a registered owner of well it is equipped with 4.5 casing and surface pipe well is being used for domestic purposes only at this point in time.
1322744572 2011-11-30 Production Wells No Violations Inspection this day due to complaint received by Dave Ball from residents of housing dervelopment. The well owner had a service rig on location and put a pumping unit and fence on/around well and installed a production tank. However, the tank is too close (7) to well. I called the well owner and left a message that he needed to move tank 50 away from the pumping unit. 12/1/11 - talked to Darel and he stated that he will get tank moved and identification signs up. I told him these issues had to be completed in the next several weeks.
1328463555 2012-02-03 Production Wells No Violations My inspection this day was to see how progressing on getting the well to pump. The owner says he needs to put one more joint of tubing and rod in the well to pump correctly. This well has a pumping unit and a small plastic tank behind a privacy fence with a lock. Close by, he had built a pad with a dike for the tank he was adding. The tubing and rods still laying on ground so it looks like little progress has been made since the last time I inspected. Identification may be behind the looked gate but I cant get in to inspect. I will continue to monitor progress.
149671105 2011-11-28 0:00 PW No Violations 0.50

For data sources see[9]

References