X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-115-21232

Well Details

Well ID: 34-115-21232
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Center Township
Operator Name: REDMAN E C /REDMAN OIL CO
Well Pad ID:
Farm/Lease Name: SILVUE P C ETAL
License Status: Plugged and Abandoned
License Date: 1971-10-18
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1971-12-25
Well Total Depth: 1602.00 ft
Configuration: Vertical
Latitude: 39.610000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1971-10-18 1901 REDMAN E C /REDMAN OIL CO GeoDate 10/18/71
Completed 1971-12-25 WELL ASSUMED PLUGGED PER 12/16/05 INSPECTION.
Reached Total Depth 1971-12-25 WELL ASSUMED PLUGGED PER 12/16/05 INSPECTION.
Record Last Modified 2016-09-26 WELL ASSUMED PLUGGED PER 12/16/05 INSPECTION.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1527 1538 1
1527 1538 1
1527 1538 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 80 Qts 0
H2O 0 550 Bbl 14000 BREAK 2300 PSI AVG. RATE 23.5 BPM AVG. PRESS. 2700 PSI SHUT IN PRESS
ACID 0 250 Gal 0

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1168224057 2012-4-5 0:00:0 FR No Violations
1068496156 2005-12-16 Field Inspected, Well Not Found No Violations Inspected well site@ request from Central Office located site from GPS coordinates well not found possibly plugged.
1168224057 2012-04-05 Final Restoration No Violations On the day of my inspection I found that the well was not plugged, there was eight inch casing with four inch well casing and tubing standing out of the ground, there is a gate valve on the tubing, there is (1) one hundred barrel production tank/seperator setting inside a containment dike, there is no permit number posted at the well site.
1488201473 2017-02-27 Field Inspected, Well Not Found No Violations I was unable to locate this well this day during my inspection. There is a path that looks to be an ATV or truck path leading up from the road to the top of the hill where this well is supposed to be located. The path looks to be recently cut up the hill and leads to some hunting stands and trail cameras leading me to believe it is used by hunters. The area this well is supposed to be located and surrounding it are all overgrown besides a few paths. I investigated around most of these paths and was unable to locate this well or any signs of a well.

For data sources see[5]