X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-24134

Well Details

Well ID: 34-111-24134
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Wayne Township
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: SKYVIEW SCHOOL
License Status: Producing
License Date: 2007-08-14
Spud Date: 2007-09-22
Spud Drilling Contractor: MONROE DRILLING OPERATION, LLC
Final Drill Date: 2007-09-26
Well Total Depth: 2565.00 ft
Configuration: Vertical
Latitude: 39.700000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-08-14 Proposed Formations:BEREA/30 FOOT/GORDON, Issued Date:8/14/2007, Expired Date:8/13/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-09-26
Completion Report Received 2008-02-20
Construction Permit Expires 2008-08-13
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-05-29 1988 1996 25
2008-05-29 2238 2290 35
1988 1996 25
2238 2290 35
2400 2509 35
1988 1996 25
2008-05-29 2400 2509 35

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 3RD STAGE OF 3-STAGE FRAC… ONLY A SINGLE WATER VOLUME WAS REPORTED FOR THE ENTIRE 3-STAGE FRAC… NO FRAC OR RESERVOIR PRESSURES WERE REPORTED… GM
H2O 0 0 0 2ND STAGE OF 3-STAGE FRAC… ONLY A SINGLE WATER VOLUME WAS REPORTED FOR THE ENTIRE 3-STAGE FRAC… NO FRAC OR RESERVOIR PRESSURES WERE REPORTED… GM
H2O 0 182610 Gal 0 1ST STAGE OF 3-STAGE FRAC… ONLY A SINGLE WATER VOLUME WAS REPORTED FOR THE ENTIRE 3-STAGE FRAC… NO FRAC OR RESERVOIR PRESSURES WERE REPORTED… GM

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BECK ENERGY CORPORATION 3674.00 133.00 0
2009 BECK ENERGY CORPORATION 2380.00 168.00 365
2010 BECK ENERGY CORPORATION 3693.00 149.00 365
2011 BECK ENERGY CORPORATION 3056.00 94.00 365
2012 BECK ENERGY CORPORATION 1757.00 58.00 366
2013 BECK ENERGY CORPORATION 1754.00 49.00 365
2014 BECK ENERGY CORPORATION 1236.00 0.00 365
2015 BECK ENERGY CORPORATION 986.00 0.00 365
2016 BECK ENERGY CORPORATION 860.00 56.00 365
2017 BECK ENERGY CORPORATION 697.00 0.00 365
2018 BECK ENERGY CORPORATION 675.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BECK ENERGY CORPORATION Brine 108
2009 BECK ENERGY CORPORATION Brine 83 365
2010 BECK ENERGY CORPORATION Brine 87 365
2011 BECK ENERGY CORPORATION Brine 61 365
2012 BECK ENERGY CORPORATION Brine 20 366
2013 BECK ENERGY CORPORATION Brine 27 365
2014 BECK ENERGY CORPORATION Brine 0 365
2015 BECK ENERGY CORPORATION Brine 0 365
2016 BECK ENERGY CORPORATION Brine 20 365
2017 BECK ENERGY CORPORATION Brine 0 365
2018 BECK ENERGY CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0325830609 2011-11-09 Preliminary Restoration No Violations On day of inspection well was complete with pump jack. Tank battery contents included: 110 bbl oil storage tank and a mechanical separator. Site met requirements of the ORC and preliminary restoration was passed.
0777386393 2008-11-10 Production Wells No Violations WELL IS SUPPLIED WITH PUMPJACK AND 100BBL TANK.NO VIOLATIONS NOTED
1343043463 2012-07-23 Production Wells No Violations Inspection of the well head found the following equipment present, 4.5 production casing, 1.5 tubing& rods with the production valves open and the well being produced by means of a pumping unit. At the production fluid storage area a 100 barrel tank and separator along with a gas sales meter are present in an established dike with proper well identification . Inspector will note both the well location and tank battery are fenced in and locked.
325830609 2011-11-9 0:00: PL No Violations 0.50
519652005 2020-6-30 0:00: PW No Violations 0.90
777386393 2008-11-10 0:00 PW No Violations

For data sources see[9]

References