X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-23789

Well Details

Well ID: 34-111-23789
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Benton Township
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: ROSENLIEB
License Status: Producing
License Date: 2002-01-22
Spud Date: 2002-03-07
Spud Drilling Contractor: R WOLFE DRLG
Final Drill Date: 2002-03-13
Well Total Depth: 2700.00 ft
Configuration: Vertical
Latitude: 39.600000
Longitude: -81.040000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2002-01-22 Proposed Formations:BEREA/GORDON/30 FOOT, Issued Date:1/22/2002, Expired Date:1/22/2003 6:00:00 AM, Drilling unit acres:36, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2002-03-07 RBDMS Rec
Completed 2002-03-13 RBDMS Rec
Reached Total Depth 2002-03-13 RBDMS Rec
Completion Report Received 2002-06-10 RBDMS Rec
Construction Permit Expires 2003-01-22 RBDMS Rec
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2002-07-03 2131 2133 7
2002-07-03 2043 2066 20
1753 1805 23
2043 2066 20
2131 2133 7
2387 2389 3
2539 2602 19
1753 1805 23
2002-07-03 2387 2389 3
2002-07-03 1753 1805 23
2002-07-03 2539 2602 19

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 157000 Gal 0 3 STAGE FRAC OF DEVONIAN SHALE & MISSISSIPPIAN SANDS

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 BECK ENERGY CORPORATION 3858.00 66.00 0
2003 BECK ENERGY CORPORATION 1970.00 42.00 365
2004 BECK ENERGY CORPORATION 944.00 0.00 365
2005 BECK ENERGY CORPORATION 656.00 0.00 365
2006 BECK ENERGY CORPORATION 637.00 0.00 365
2007 BECK ENERGY CORPORATION 640.00 0.00 365
2008 BECK ENERGY CORPORATION 524.00 0.00 365
2009 BECK ENERGY CORPORATION 478.00 0.00 365
2010 BECK ENERGY CORPORATION 562.00 60.00 365
2011 BECK ENERGY CORPORATION 473.00 27.00 365
2012 BECK ENERGY CORPORATION 402.00 0.00 366
2013 BECK ENERGY CORPORATION 283.00 0.00 365
2014 BECK ENERGY CORPORATION 246.00 11.00 365
2015 BECK ENERGY CORPORATION 318.00 0.00 365
2016 BECK ENERGY CORPORATION 370.00 24.00 365
2017 BECK ENERGY CORPORATION 351.00 0.00 365
2018 BECK ENERGY CORPORATION 280.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 BECK ENERGY CORPORATION Brine 55
2003 BECK ENERGY CORPORATION Brine 20 365
2004 BECK ENERGY CORPORATION Brine 0 365
2005 BECK ENERGY CORPORATION Brine 60 365
2006 BECK ENERGY CORPORATION Brine 0 365
2007 BECK ENERGY CORPORATION Brine 0 365
2008 BECK ENERGY CORPORATION Brine 0 365
2009 BECK ENERGY CORPORATION Brine 0 365
2010 BECK ENERGY CORPORATION Brine 28 365
2011 BECK ENERGY CORPORATION Brine 58 365
2012 BECK ENERGY CORPORATION Brine 0 366
2013 BECK ENERGY CORPORATION Brine 0 365
2014 BECK ENERGY CORPORATION Brine 67 365
2015 BECK ENERGY CORPORATION Brine 0 365
2016 BECK ENERGY CORPORATION Brine 54 365
2017 BECK ENERGY CORPORATION Brine 0 365
2018 BECK ENERGY CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1364201846 2002-4-15 0:00: PW No Violations
-905620446 2020-3-31 0:00: PW No Violations 0.40
1199817071 2004-06-30 Preliminary Restoration No Violations Restoration satisfactory,will need dike around production tank when SPCC rules goes into effect.
1364201846 2002-04-15 Production Wells No Violations status check ref. Report of tank fire. on site inspection with operator shows no damage at tank site,static electric probably started fire at tank local fire dept. used foam to put it out.supervisor notified.
1525798206 2018-05-08 Production Wells No Violations Status check inspection found the well equipped with 4.5 diameter production casing along with 1.900 diameter production tubing. There are production valves and flow lines attached to the tubing and casing well heads and the valves are in the open position. The well is set up to be produced by the means of a gasoline powered motor. At the production facility a single 100 barrel steel construction production tank is present along with a 1200 gallon plastic tank. Also present at the production facility is a mechanical separator and gas sales meter with a current sales chart present in the meter. There is well identification posted. The tank battery sits in close proximity to a home and a stream identified as Trail Run.

For data sources see[9]

References