Well Details

Well ID: 34-105-22359
Loading map...
Country: United States
State: Ohio
County: Meigs
Municipality: Salisbury Township
Operator Name: SMITH RONALD DBA CHIPCO
Well Pad ID:
Farm/Lease Name: LAMBERT
License Status: Producing
License Date: 2012-12-11
Spud Date: 1982-05-08
Spud Drilling Contractor:
Final Drill Date: 1982-05-14
Well Total Depth: 2214.00 ft
Configuration: Vertical
Latitude: 39.090000
Longitude: -82.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-12-31 1336 AKRON OIL CORP GeoDate 12/31/81
Oil and Gas 1981-12-31 Issued Date 12/31/81 Expired Date Acres 0000000 Tool Type Proposed Formation Proposed Depth Proposed Drill Depth
Original Spud 1982-05-08
Completed 1982-05-14
Reached Total Depth 1982-05-14
Change of Owner 1984-02-02 Change Owner From 435 HANLEY HARDIN to 1336 AKRON OIL CORPORATION: 2-2-1984
Change of Owner 2003-06-16 Operator changed from 1336, AKRON OIL CORP to 6295, KNOX ENERGY INC.
Change of Owner 2011-10-13 Operator changed from 6295, KNOX ENERGY INC. to 7640, SMITH RONALD DBA CHIPCO
APP 2012-12-11 Proposed Formations:BEREA, Issued Date:12/11/2012, Expired Date:12/11/2014 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Plugged Back 2013-01-29
Construction Permit Expires 2014-12-11
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0
2013-02-15 H2O 0 34051 Gal 0 Producers Service Corporation

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 AKRON OIL CORP 0.00 0.00 0
1985 AKRON OIL CORP 0.00 0.00 0
1986 AKRON OIL CORP 0.00 0.00 365
1987 AKRON OIL CORP 8.00 199.00 180
1988 AKRON OIL CORP 0.00 55.00 162
2003 KNOX ENERGY INC. 0.00 0.00 365
2004 KNOX ENERGY INC. 0.00 0.00 366
2005 KNOX ENERGY INC. 0.00 0.00 365
2006 KNOX ENERGY INC. 0.00 0.00 0
2007 KNOX ENERGY INC. 0.00 106.00 365
2008 KNOX ENERGY INC. 0.00 20.00 365
2009 KNOX ENERGY INC. 0.00 0.00 0
2010 KNOX ENERGY INC. 0.00 0.00 0
2012 SMITH RONALD DBA CHIPCO 0.00 0.00 366
2014 SMITH RONALD DBA CHIPCO 861.00 179.00 365
2015 SMITH RONALD DBA CHIPCO 621.00 130.00 365
2016 SMITH RONALD DBA CHIPCO 335.00 180.00 365
2017 SMITH RONALD DBA CHIPCO 406.00 84.00 365
2018 SMITH RONALD DBA CHIPCO 183.00 72.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 AKRON OIL CORP Brine 0 0
1985 AKRON OIL CORP Brine 0 0
1986 AKRON OIL CORP Brine 0 365
1987 AKRON OIL CORP Brine 20 180
1988 AKRON OIL CORP Brine 415 162
2003 KNOX ENERGY INC. Brine 0 365
2004 KNOX ENERGY INC. Brine 0 366
2005 KNOX ENERGY INC. Brine 0 365
2006 KNOX ENERGY INC. Brine 0 0
2007 KNOX ENERGY INC. Brine 0 365
2008 KNOX ENERGY INC. Brine 35 365
2009 KNOX ENERGY INC. Brine 0 0
2010 KNOX ENERGY INC. Brine 0 0
2012 SMITH RONALD DBA CHIPCO Brine 0 366
2014 SMITH RONALD DBA CHIPCO Brine 0 365
2015 SMITH RONALD DBA CHIPCO Brine 0 365
2016 SMITH RONALD DBA CHIPCO Brine 0 365
2017 SMITH RONALD DBA CHIPCO Brine 0 365
2018 SMITH RONALD DBA CHIPCO Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1025436750 2014-4-24 0:00: PW No Violations 3.00
-2092369633 2013-6-11 0:00: UP No Violations 0.50
-529791506 2014-4-21 0:00: PW No Violations 0.80
-560014791 2013-12-30 0:00 PW No Violations 0.30
-976902387 2014-4-24 0:00: PW No Violations 0.30
0188453382 2013-12-30 Production Wells No Violations There was 1-2 feet of contaminated water on the lower edge of the dike. Fluids shall be removed from dike and disposed of properly.
0365960728 2013-12-30 Preliminary Restoration No Violations Restoration requirements met.
0529791506 2014-04-21 Production Wells No Violations Compliance Notice Follow-up -2092369633: The fence has not been installed around the well or tanks as required by 1509:9-9-050 E(2). I called and left Chip Smith a message regarding the issues.
0560014791 2013-12-30 Production Wells No Violations Follow up to -2092369633. The fence has not been installed around the well or tanks yet.
0938346280 2013-02-11 Plug / Plug Back No Violations The plug was knocked down hole and TD was checked at 1692. A bond log was run and shows the top of cement on the squeeze job was 810 feet. The casing was perforated in the 2nd Berea Sandstone with 21 shots from 1560-1570, 13 shots from 1574-1580, and 9 shots from 1586-1590 feet.
0976902387 2014-04-24 Production Wells No Violations Follow up to 2092369633 & 188453382. Inspector LJ Parkins followed up on violations. Both of the violations have been relieved.
1025436750 2014-04-24 Production Wells No Violations This well is in RBDMS as Plugged and Abandoned, it is not plugged. This well was plugged back to the Berea Sandstone in February 2013 and is currently producing from that formation. The well consists of a pumping unit driven by a gasoline power unit. There is a drip, mechanical separator, and (2) 100 bbl tanks sitting within a containment dike. All valves are in the open position. The well is fully capable of production. Upon reading prior inspections, I discovered this well has an open violation for failing to install a fence around the well and tank battery within an urbanized drilling area. The fence has been installed around the well and the tank battery since this violation was issued.
1039631861 2002-12-10 Production Wells No Violations An inspection of the well revealed the well to be Idle and incapable of producing, well is equipped with tubing, rods, pump jack, and production tanks. It appears no house gas is being used from well.
1329510886 2012-02-17 Production Wells No Violations Upon inspection the service rig crew was running tubing in hole. The company plans to clean out the hole with a power swivel and produce the well. A pit will be dug and a mud pump is on site to kill the well if necessary.
1330459342 2012-02-28 Production Wells No Violations The pumping unit is running, the pit is closed, and the site is being reclaimed.
1359149300 2013-01-25 Plug / Plug Back No Violations Witnessed bottom hole plug set in well. 20 sacks of class A cement used.
1359476542 2013-01-29 Plug / Plug Back No Violations The Bottom Plug was tagged at 2003 feet. Another 250 plug was set on top of that from 2003 to 1753 feet. 19 sacks class A cement used. Fluid circulated into tanks due to site conditions.
1360086722 2013-02-05 Plug / Plug Back No Violations Administered the production casing pressure test. 820 psi was held on the casing for the required 30 minute test period. No pressure was lost during the testing period. The production casing was perforated at 1360 in order to squeeze cement up the backside of the production casing for the new completion of the well. The well is plumbed to circulate into tanks because of the low laying area of the site. The production casing was filled with fresh water to circulate before the cement was pumped into the annular space. Almost immediately circulation was seen at the surface from below ground. The pumps were turned off and the water that flowed back was sucked into the 80 Barrel water truck. The well head was dug out and a small hole was found in the surface casing roughly a foot below the surface. The cement job was canceled until the hole in the surface casing can be patched.
1360173900 2013-02-06 Plug / Plug Back No Violations Witnessed a squeeze job on backside of production casing. 100 sacks of Class A neat cement were displaced using 21.9 Barrels of fresh water and squeezed through the perforations in the production casing at 1360 feet.
1360948900 2013-02-15 Completion Testing No Violations Witnessed completion of well in Berea Sandstone. Roughly 34,000 gallons used to treat formation, which broke down at 1720 psi. Casing perforated from 1560-1590.
1382121073 2013-10-18 Production Wells No Violations Follow up to -2092369633. The well is now in an urban towhsip and has been recently reworked by company. The well does not meet the Urban fencing requirments.
188453382 2013-12-30 0:00 PW No Violations 0.30
2092369633 2013-06-11 UrbanProduction Wells Violations Noted Well equipped with an pumping unit and gasoline engine. Tank battery equipped with two 100 barrel steel tanks and a separator. Well not equipped with an identification. Neither well nor tank equipped with required fencing for urban areas. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. Well shall be equipped in order to comply with 1501:9-9-05 E 1-4, urban requirements.
365960728 2013-12-30 0:00 PL No Violations 0.30
938346280 2013-2-11 0:00: PB No Violations 4.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2092369633 US-OH-121368 2014-04-30 ID (a-i)
2092369633 US-OH-121369 2014-04-30 FENCING (a-d)
2092369633 US-OH-121370 2014-04-30 LOCKS
2092369633 US-OH-121371 2014-04-30 TANKS (a-i)

For data sources see[8]