34-103-24849

Well Details

Well ID: 34-103-24849
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Montville Township
Operator Name: TRANSCONTINENTAL OIL & GAS INC
Well Pad ID:
Farm/Lease Name: WARGO
License Status: Producing
License Date: 1995-11-02
Spud Date: 1996-05-08
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1996-05-13
Well Total Depth: 3586.00 ft
Configuration: Vertical
Latitude: 41.070000
Longitude: -81.870000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1995-11-02 Issued Date 11/2/95 Expired Date 11/1/96 Acres 0020236 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03586 Proposed Drill Depth 03586
Original Spud 1996-05-10
Completed 1996-05-13
Reached Total Depth 1996-05-13
CO 1996-07-06 4744 TRANSCONTINENTAL O & G GeoDate 11/2/95
Construction Permit Expires 1996-11-01
Completion Report Received 1996-11-25
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3321 3408 0
3321 3408 0
2006-09-11 3345 3399 31
3345 3399 31
3321 3408 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 86381 Gal 56000 FRAC W/86,381 GAL WATER,173MSCF N2
N2 0 173 Mscf 0 TREAT. 15 BPM @ 1370 PSI, 1475 PSI, 25 BPM 1638 PSI, 30 BPM @ 1858 PSI, ISIP 1188 PSI

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1996 TRANSCONTINENTAL OIL & GAS INC 614.00 0.00 30
1998 TRANSCONTINENTAL OIL & GAS INC 4796.00 0.00 365
1999 TRANSCONTINENTAL OIL & GAS INC 6024.00 0.00 365
2000 TRANSCONTINENTAL OIL & GAS INC 4799.00 0.00 365
2001 TRANSCONTINENTAL OIL & GAS INC 3158.00 0.00 365
2002 TRANSCONTINENTAL OIL & GAS INC 1484.00 0.00 365
2003 TRANSCONTINENTAL OIL & GAS INC 3476.00 0.00 365
2004 TRANSCONTINENTAL OIL & GAS INC 3464.00 0.00 365
2005 TRANSCONTINENTAL OIL & GAS INC 2818.00 0.00 365
2006 TRANSCONTINENTAL OIL & GAS INC 1801.00 0.00 365
2007 TRANSCONTINENTAL OIL & GAS INC 4201.00 0.00 364
2008 TRANSCONTINENTAL OIL & GAS INC 2491.00 0.00 365
2009 TRANSCONTINENTAL OIL & GAS INC 2624.00 0.00 365
2010 TRANSCONTINENTAL OIL & GAS INC 2412.00 0.00 365
2011 TRANSCONTINENTAL OIL & GAS INC 1901.00 0.00 365
2012 TRANSCONTINENTAL OIL & GAS INC 1878.00 0.00 366
2013 TRANSCONTINENTAL OIL & GAS INC 2147.00 0.00 365
2014 TRANSCONTINENTAL OIL & GAS INC 1480.00 0.00 365
2015 TRANSCONTINENTAL OIL & GAS INC 1217.00 0.00 365
2016 TRANSCONTINENTAL OIL & GAS INC 1415.00 0.00 365
2017 TRANSCONTINENTAL OIL & GAS INC 1261.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1996 TRANSCONTINENTAL OIL & GAS INC Brine 1200 30
1998 TRANSCONTINENTAL OIL & GAS INC Brine 40 365
1999 TRANSCONTINENTAL OIL & GAS INC Brine 47 365
2000 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2001 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2002 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2003 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2004 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2005 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2006 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2007 TRANSCONTINENTAL OIL & GAS INC Brine 0 364
2008 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2009 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2010 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2011 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2012 TRANSCONTINENTAL OIL & GAS INC Brine 0 366
2013 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2014 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2015 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2016 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2017 TRANSCONTINENTAL OIL & GAS INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1738371143 2015-9-28 0:00: PW No Violations
0536888418 2014-04-22 Production Wells No Violations Inspected production well on 04/22/2014. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and a production unit within an earthen dike. The diked area is located within an unlocked metal fence. The well is a rabbit well located within a locked metal fence. No well identification is posted at either the tank battery or the wellhead. Cal Marks with Transcontinental Oil and Gas was notified of this problem and will address it as soon as possible. No other problems were noted at the time of the inspection.
1192724211 2007-10-18 Production Wells No Violations Case # 07-016. Called in by Nancy Coe that well is leaking gas. Inspected well, tank battery and gas line in woods near homes on Hidden Acres Dr and found no gas leak or odor of gas in area. Well is producing by a rabbit. No violations at well ot tank battery. Advised company to repair fence around well. Called Nancy Coe to advise of findings.
1363194213 2013-03-12 Production Wells No Violations I inspected this well and found one plunger lift system installed on the wellhead. There were gauges installed on the tubing and on the casing, but I was not able to access them due to the entire wellhead being enclosed with a triangular shaped steel chain link barbed wire fence with a locked access gate. No leaks were observed on the wellhead or on the piping around the wellhead. A small gas sales chart recorder was installed on the piping from the wellhead and a residential type gas meter with regulator was plumbed off of the casing. The area within the fence and outside of the fence was well maintained. The tank battery contained one 100 bbl. steel oil storage tank, one 50 bbl. steel brine storage tank, one horizontal oil and gas separator unit and one drip assembly. There was a residential type gas meter and regulator plumbed off of the separator unit. An identification sign was posted on the steel tank, but the required information was washed off of the sign from the weather. No leaks were observed on the tanks or piping within the tank battery. The entire tank battery was enclosed with a steel chain link barbed wire fence with a locked access gate. The dike was in good shape and the area within and around the tank battery was well maintined. I contacted Cal Marks of Transconinental O & G and advised him of the missing information on the identification sign. He advised me that he will take care of the sign within a week.
1738371143 2015-09-28 Production Wells No Violations Inspected production well on 09/28/2015. The tank battery consists of 1-100 bbl steel tank, 1-50 bbl steel tank, and 1-horizontal separator located within an earthen dike and locked metal fence. The well is a rabbit well located within a locked metal fence. Well identification is clearly displayed at the wellhead. No problems were noted at the time of the inspection.
536888418 2014-4-22 0:00: PW No Violations

For data sources see[9]