X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-23978

Well Details

Well ID: 34-103-23978
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Montville Township
Operator Name: VIRMURCO INC
Well Pad ID:
Farm/Lease Name: VIRMURCO
License Status: Producing
License Date: 1984-11-30
Spud Date: 1984-12-07
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1984-12-10
Well Total Depth: 3602.00 ft
Configuration: Vertical
Latitude: 41.080000
Longitude: -81.860000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-11-30 2034 VIRMURCO INC GeoDate 11/30/84
Oil and Gas 1984-11-30 Issued Date 11/30/84 Expired Date 5/29/85 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03602 Proposed Drill Depth 03602
Original Spud 1984-12-07
Completed 1984-12-10
Reached Total Depth 1984-12-10
Construction Permit Expires 1985-05-29
Completion Report Received 1985-11-29
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3396 3478 0
3396 3478 0
2006-09-11 3418 3439 12
3418 3439 12
3396 3478 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 79000 Gal 45000 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1999 RESOURCE AMERICA INC 469.00 0.00 365
2000 SHONGUM OIL & GAS INC 557.00 28.00 359
2008 VIRMURCO INC 0.00 0.00 0
2009 VIRMURCO INC 0.00 0.00 0
2010 VIRMURCO INC 0.00 0.00 0
2016 VIRMURCO INC 0.00 0.00 0
2017 VIRMURCO INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1999 RESOURCE AMERICA INC Brine 226 365
2000 SHONGUM OIL & GAS INC Brine 0 359
2008 VIRMURCO INC Brine 0 0
2009 VIRMURCO INC Brine 0 0
2010 VIRMURCO INC Brine 0 0
2016 VIRMURCO INC Brine 0 0
2017 VIRMURCO INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-534501687 2011-12-13 0:00 PW No Violations
-817853629 2014-5-1 0:00:0 PW No Violations
000PL11523 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0020979440 2002-07-31 Production Wells No Violations Status check inspection - Oil stained soil and gravel in and around the containment dike. The well and tank battery have no identification. The electric wire has become detached from the fourth utility pole from the well head. The electric needs to be reattached and the well head and tank battery need identification.
002155i284 2002-09-04 Production Wells No Violations NOV follow-up inspection indicated that the requested actions have not been completed. These actions included spill remediation in the tank battery, wellhead and tank battery ID and repairing a downed electric line. I contacted Greg Miller with Virmurco while at the site. He stated that they have been waiting for Resource America to complete the required work and that Resource should be on site the week of September 9.
002155i320 2002-09-23 Production Wells No Violations The tank battery spill has been partially remediated. The stock tank has been replaced and replumbed. The tank battery and well head still need identification signs and the electric line is still sagging. Greg Miller, with Virmurco, said that the signs will be installed and the electric line will be reattached to the pole.
002155i372 2002-10-17 Production Wells No Violations Violation has been corrected.
0534501687 2011-12-13 Production Wells No Violations The required identification is posted, water has been removed by S&H Water Service and the impacted soil has been stockpiled on site.
0817853629 2014-05-01 Production Wells Violations Noted Inspected production well on 05/01/2014. The well is equipped with a pump jack with an electric motor located within an earthen dike. The diked area is located within an unlocked metal fence. The well identification had fallen off the well and was laying on the ground. No tanks were noted nearby. Research into the production of the well showed that the well has not reported production to ODNR since 2010 and that the well has not produced since 2010, therefore the well must be plugged.
0883735107 2011-12-02 Production Wells Violations Noted The Uniontown office received a call from Kurt Weaver (330-723-2551) at 6979 Wooster Pike in Montville Township reporting dead vegetation adjacent to a tank battery on his property. The inspection found no identification on the tank battery or the wellhead and a brine scald that extended from the tank battery to the east and northeast approximately 60. High range Quantabs reached their maximum response over 6300 PPM chlorides. While conducting the inspection, Greg Miller with Virmurco arrived on site. We discussed the corrective actions that are required and the timeline to complete. Identification will be posted at the well and tank battery within 24 hours. A vac truck (S&H) will recover standing water in the impacted area and the surface will be scraped with the soil disposed at Petrocell. Seed and mulch will be applied as soon as weather permits.
1037939432 2012-01-09 Production Wells No Violations The chloride level in the water adjacent to the tank battery is reduced from Quantab saturation to 3340 PPM. The impacted soil has been removed. The site will be checked in the spring to verify continued dilution of the release and any lingering affect on the vegetation.
1078506202 2004-03-05 Production Wells No Violations Requested by Sherry Young. Gas being produced from well. Electric is disconnected from pole, meter removed. No production reported since 2000.
1086133947 2015-03-09 Production Wells No Violations Inspected production well on 03/09/2015 to follow-up on previously issued compliance notice (failure to file production). The well is equipped with a pump jack with an electric motor located within an unlocked metal fence. No well identification is posted. No tanks are located nearby. No contact has been made by the well owner, nor has any action been taken to correct problems with the well. Well may require a Chiefs Order to reach compliance.
1169667550 2007-01-24 Production Wells No Violations Called by Montville zoning inspector, Judy Emrik. The electric line leading from transformer to well is sagging. Landowner is concerned for his grandchildrens saftey. The electric meter was pulled in 2000 and well is used to run the factory,Virmuco Inc. Electric line is 12 above ground. Advised Judy Emrik and Mr. Spencer of findings. No violations at this time. Snow,30 degrees.
20979440 2002-7-31 0:00: PW No Violations
2155i284 2002-9-4 0:00:0 PW No Violations
2155i320 2002-9-23 0:00: PW No Violations
2155i372 2002-10-17 0:00 PW No Violations
883735107 2011-12-2 0:00: PW No Violations
PL11523 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0817853629 US-OH-129313 2014-05-19 Well shall be plugged
0817853629 US-OH-129314 2014-05-19 Statement of annual production not filed
0883735107 US-OH-130054 2011-12-12 Well operation causing pollution and contamination
0883735107 US-OH-130055 2011-12-12 General Safety
0883735107 US-OH-130056 2011-12-12 Failure to legibly identify well

For data sources see[9]

References