Well Details

Well ID: 34-103-23587
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Granger Township
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: BEOHMERLE AUSTIN
License Status: Producing
License Date: 1983-12-05
Spud Date: 1984-05-03
Spud Drilling Contractor: NANCY DRLG
Final Drill Date: 1984-05-09
Well Total Depth: 3614.00 ft
Configuration: Vertical
Latitude: 41.150000
Longitude: -81.710000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-12-05 212 WATERCO INC GeoDate 12/5/83
Oil and Gas 1983-12-05 Issued Date 12/5/83 Expired Date 6/2/84 Acres 0020613 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03614 Proposed Drill Depth 03614
Original Spud 1984-05-03
Completed 1984-05-09
Reached Total Depth 1984-05-09
Construction Permit Expires 1984-06-02
Completion Report Received 1984-09-20
Change of Owner 2001-01-29 Operator changed from 212, WATERCO INC to 70, WALDRON DAVID A & ASS INC
Change of Owner 2016-10-11 Operator changed from 70, DAVID A WALDRON & ASSOC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3424 3529 0
3424 3529 0
2006-09-11 3445 3484 2
3445 3484 2
3424 3529 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 74270 Gal 41700 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 SHADCO INC 4652.00 629.00 365
1985 SHADCO INC 9325.00 646.00 165
1986 SHADCO INC 11543.00 650.00 294
1987 SHADCO INC 8053.00 305.00 216
1988 SHADCO INC 7458.00 168.00 365
1989 SHADCO INC 0.00 0.00 365
1990 SHADCO INC 5322.00 249.00 365
1991 SHADCO INC 1997.00 86.00 365
1992 SHADCO INC 4228.00 189.00 365
1993 WATERCO INC 3249.00 88.00 365
1995 WATERCO INC 2705.00 165.00 365
1996 WATERCO INC 2668.00 207.00 365
1997 WATERCO INC 2469.00 0.00 365
1998 WATERCO INC 2049.00 156.00 365
1999 WATERCO INC 2137.00 72.00 365
2000 WATERCO INC 1945.00 258.00 365
2001 DAVID A WALDRON & ASSOC 1743.00 196.00 365
2002 DAVID A WALDRON & ASSOC 1964.00 0.00 365
2003 DAVID A WALDRON & ASSOC 1820.00 107.00 365
2004 DAVID A WALDRON & ASSOC 1646.00 187.00 365
2005 DAVID A WALDRON & ASSOC 1350.00 116.00 365
2006 DAVID A WALDRON & ASSOC 1350.00 59.00 365
2007 DAVID A WALDRON & ASSOC 1811.00 128.00 365
2008 DAVID A WALDRON & ASSOC 1617.00 191.00 365
2009 DAVID A WALDRON & ASSOC 1438.00 104.00 365
2010 DAVID A WALDRON & ASSOC 1392.00 93.00 365
2011 DAVID A WALDRON & ASSOC 1456.00 88.00 365
2012 DAVID A WALDRON & ASSOC 1210.00 71.00 366
2013 DAVID A WALDRON & ASSOC 1358.00 73.00 365
2014 DAVID A WALDRON & ASSOC 1188.00 65.00 365
2015 DAVID A WALDRON & ASSOC 1194.00 79.00 365
2016 DAVID A WALDRON & ASSOC 1207.00 53.00 365
2017 PIN OAK ENERGY PARTNERS LLC 1162.00 59.00 365
2018 PIN OAK ENERGY PARTNERS LLC 670.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 SHADCO INC Brine 420 365
1985 SHADCO INC Brine 290 165
1986 SHADCO INC Brine 181 294
1987 SHADCO INC Brine 123 216
1988 SHADCO INC Brine 129 365
1989 SHADCO INC Brine 118 365
1990 SHADCO INC Brine 120 365
1991 SHADCO INC Brine 0 365
1992 SHADCO INC Brine 130 365
1993 WATERCO INC Brine 0 365
1995 WATERCO INC Brine 0 365
1996 WATERCO INC Brine 0 365
1997 WATERCO INC Brine 75 365
1998 WATERCO INC Brine 365
1999 WATERCO INC Brine 365
2000 WATERCO INC Brine 56 365
2001 DAVID A WALDRON & ASSOC Brine 20 365
2002 DAVID A WALDRON & ASSOC Brine 0 365
2003 DAVID A WALDRON & ASSOC Brine 0 365
2004 DAVID A WALDRON & ASSOC Brine 67 365
2005 DAVID A WALDRON & ASSOC Brine 70 365
2006 DAVID A WALDRON & ASSOC Brine 0 365
2007 DAVID A WALDRON & ASSOC Brine 0 365
2008 DAVID A WALDRON & ASSOC Brine 50 365
2009 DAVID A WALDRON & ASSOC Brine 60 365
2010 DAVID A WALDRON & ASSOC Brine 0 365
2011 DAVID A WALDRON & ASSOC Brine 55 365
2012 DAVID A WALDRON & ASSOC Brine 0 366
2013 DAVID A WALDRON & ASSOC Brine 70 365
2014 DAVID A WALDRON & ASSOC Brine 35 365
2015 DAVID A WALDRON & ASSOC Brine 0 365
2016 DAVID A WALDRON & ASSOC Brine 65 365
2017 PIN OAK ENERGY PARTNERS LLC Brine 0 365
2018 PIN OAK ENERGY PARTNERS LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
000PL11678 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1312894720 2014-10-27 Production Wells No Violations Inspected production well on 10/27/2014. The tank battery consists of 1-210 bbl steel tank, 1-100 bbl steel tank, 1-50 bbl steel tank, 1-vertical separator, drip, and meter assembly located within an earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1366150770 2013-04-16 Production Wells No Violations I inspected this well and found one electric powered pump jack on the wellhead. I could not determine the pressure on the tubing or on the casing as there were no gauges installed on either. There was a small well identification sign mounted on the pump jack, but it incorrectly identified the well owner as Lomak Petroleum when the current well owner is actually D.A. Waldron & Assoc. There was a residential type gas meter with a regulator that was plumbed into the casing and was supplying gas to a residence that was located some distance away from the well. No leaks were seen on the wellhead or on the adjacent piping around the wellhead. There was an earthen dike constructed around the wellhead and pump jack and the area around the well was nicely maintained. The tank battery contained one 50 bbl. steel oil storage tank and one horizontal oil and gas separator unit. There was no identification sign posted on the storage tank or anywhere else in the tank battery, but there was a proper identification sign posted for this well at the entrance of the lease road. The dike was in good shape, but the area within and around the dike contained an excessive amount of high weed growth. I contacted Jerry Reeves of D.A. Waldron & Assoc. and advised him of the incorrect well identification sign on the pump jack.
PL11678 PL No Violations

For data sources see[9]

References