X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-103-23031

Well Details

Well ID: 34-103-23031
Loading map...
Country: United States
State: Ohio
County: Medina
Municipality: Sharon Township
Operator Name: POLING DAVID L
Well Pad ID:
Farm/Lease Name: MORRIS-POLING
License Status: Plugged and Abandoned
License Date: 2017-06-21
Spud Date: 1982-03-12
Spud Drilling Contractor:
Final Drill Date: 1982-03-18
Well Total Depth: 3845.00 ft
Configuration: Vertical
Latitude: 41.120000
Longitude: -81.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1982-03-11 3913 POLING DAVID L GeoDate 3/11/82
Oil and Gas 1982-03-11 Issued Date 3/11/82 Expired Date 9/7/82 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03845 Proposed Drill Depth 03845
Original Spud 1982-03-12
Completed 1982-03-18
Reached Total Depth 1982-03-18
Completion Report Received 1986-05-15
APP 2017-06-21 Proposed Formations:CLINTON, Issued Date:6/21/2017, Expired Date:6/21/2019 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2017-06-28
Construction Permit Expires 2019-06-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3618 3642 12
3618 3642 12
3618 3642 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1147 Bbl 5500

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GASEARCH INC 14052.00 1775.00 365
1985 GASEARCH INC 7445.00 730.00 365
1986 EASTERN PETROLEUM CO 3804.00 334.00 365
1987 EASTERN PETROLEUM CO 2594.00 288.00 365
1988 EASTERN PETROLEUM CO 1647.00 111.00 365
1989 EASTERN PETROLEUM CO 480.00 123.00 365
2003 POLING DAVID L 0.00 0.00 0
2004 POLING DAVID L 0.00 0.00 0
2005 POLING DAVID L 0.00 0.00 0
2006 POLING DAVID L 0.00 0.00 0
2007 POLING DAVID L 0.00 0.00 0
2008 POLING DAVID L 0.00 0.00 0
2009 POLING DAVID L 0.00 0.00 0
2010 POLING DAVID L 0.00 0.00 0
2011 POLING DAVID L 0.00 0.00 0
2012 POLING DAVID L 0.00 0.00 0
2013 POLING DAVID L 0.00 0.00 0
2014 POLING DAVID L 0.00 0.00 0
2015 POLING DAVID L 0.00 0.00 0
2016 POLING DAVID L 0.00 0.00 0
2017 POLING DAVID L 0.00 0.00 235

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GASEARCH INC Brine 0 365
1985 GASEARCH INC Brine 0 365
1986 EASTERN PETROLEUM CO Brine 40 365
1987 EASTERN PETROLEUM CO Brine 45 365
1988 EASTERN PETROLEUM CO Brine 25 365
1989 EASTERN PETROLEUM CO Brine 0 365
2003 POLING DAVID L Brine 0 0
2004 POLING DAVID L Brine 0 0
2005 POLING DAVID L Brine 0 0
2006 POLING DAVID L Brine 0 0
2007 POLING DAVID L Brine 0 0
2008 POLING DAVID L Brine 0 0
2009 POLING DAVID L Brine 0 0
2010 POLING DAVID L Brine 0 0
2011 POLING DAVID L Brine 0 0
2012 POLING DAVID L Brine 0 0
2013 POLING DAVID L Brine 0 0
2014 POLING DAVID L Brine 0 0
2015 POLING DAVID L Brine 0 0
2016 POLING DAVID L Brine 0 0
2017 POLING DAVID L Brine 0 235

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0004014930 2015-04-23 Production Wells No Violations Inspected production well on 04/23/2015 to follow-up on a previously-issued compliance notice. The tank battery consists of 2-210 bbl steel tanks located within an earthen dike. 2-horizontal separators are located nearby, outside of the diked area. No well identification is posted at the wellhead as required. The well is equipped with a pump jack with an electric motor. No well identification is posted at the wellhead. Spoke to Mr. Poling on-site - he is still trying to decide if he wants to plug the well or try to swab it and use it for his home. A 6-month extension to the compliance notice has been granted to allow him time to either swab or plug the well.
000PL11958 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0138935692 2005-06-06 Production Wells No Violations Requested by Sherry Young to inspect well. Well is equipped with pump jack, rods and tubing. No outstanding violationd except bonding requirements. Hot, 85 degrees.
138935692 2005-6-6 0:00:0 PW No Violations 1.00
1396186492 2014-06-27 Production Wells Violations Noted Inspected production well on 06/27/2014. The tank battery consists of 2-210 bbl steel tanks located within an earthen dike. 2-horizontal separators are located nearby, outside of the diked area. The well is equipped with a pump jack with no apparent motor. The well is shut-in at the time of the inspection. No identification is posted at either the tank battery or the wellhead as required. Research into the production history of the well showed that it has not produced since 1989, therefore the well must be plugged.
4014930 2015-4-23 0:00: PW No Violations
PL11958 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1396186492 US-OH-111721 2015-01-08 Failure to legibly identify well
1396186492 US-OH-111722 2015-01-08 Well shall be plugged

For data sources see[9]

References