If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-22365 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.08,"lon":-80.76,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Austintown Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: HENIK MICHAEL G& LINDA M | |
License Status: Producing | |
License Date: 1990-01-31 | |
Spud Date: 1990-02-12 | |
Spud Drilling Contractor: SHERMAN DRLG | |
Final Drill Date: 1990-02-16 | |
Well Total Depth: 5404.00 ft | |
Configuration: Vertical | |
Latitude: 41.080000 | |
Longitude: -80.760000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1989-11-13 | 1388 NORTH COAST ENERGY INC GeoDate 11/13/89 |
Oil and Gas | 1989-11-13 | Issued Date 11/13/89 Expired Date 11/13/90 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1990-01-31 | 1388 NORTH COAST ENERGY INC GeoDate 1/31/90 |
Oil and Gas | 1990-01-31 | Issued Date 11/13/89 Expired Date 11/13/90 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05404 Proposed Drill Depth 05404 |
Original Spud | 1990-02-12 | |
Completed | 1990-02-16 | |
Reached Total Depth | 1990-02-16 | |
Completion Report Received | 1990-04-13 | |
Construction Permit Expires | 1990-11-13 | |
Change of Owner | 2010-05-06 | Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5155 | 5270 | 0 |
5155 | 5270 | 0 | |
2006-09-11 | 5181 | 5260 | 60 |
5181 | 5260 | 60 | |
5155 | 5270 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 600 Gal | 0 | FE ACID, 600 CWT 20/40 SAND AVG TREAT PRESS 2200 PSI @ 54 BPM, ISIP 1000 PSI, 5 MIN 900 PSI; | ||
H2O | 0 | 156000 Gal | 0 | FRAC:ACID/SAND/WATER |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
000PL12477 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
1248373839 | 2009-07-22 | Production Wells | No Violations | I received a call from Andy Koval(North Coast) about a problem he was having with a landowner about a contaminated pond. Mr. Sadie claimed that the North Coasts well leaked brine into his pond. Fish were dying in Mr. Sadies pond. Andy did not find any leaks around the wellhead or the tank battery. He asked me to test the pond for brine contamination. I arrived on site 1 hour later. I met with the landowner, Mr. Phil Sadie of 2105 Smith Canfield, Niles road(rte 46). Mr. Sadie had already drained the pond but had a quart jar of the pond water in it. I preformed a Quantab test and a PH test. The PH test showed the pond water a 7 on the PH scale. The Quantab read 0. I showed the results to Mr. Sadie who was standing by me the through the whole procedure. He seemed satisfied about the results. Andy thanked me for coming out. Case resolved. |
1650145639 | 2009-01-15 | Production Wells | No Violations | I performed a random field inspection. Both the wellhead and the tank battery were GPSd for the first time. I continued to walk around both the tank battery and the well and found both to be in good shape. The ID sign was posted. There were no violations at this time. |
PL12477 | PL | No Violations |
For data sources see[9]