Well Details

Well ID: 34-093-60551
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: HISTORIC OWNER
Well Pad ID:
Farm/Lease Name: CHALFANT MFG
License Status: Orphan Well - Pending
License Date:
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.350000
Longitude: -82.110000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 2008-02-14 WELL WAS INSPECTED BY HAROLD MORAVY ON 4/28/2006. WELL WAS LEAKING GAS AT 100% LEL. FOUND 12 INCH BOREHOLE 8 FEET BELOW GROUND SURFACE. SET 8 INCH PVC VENT PIPE IN WELL AND BACK FILLED HOLE. NO METAL CASING IN WELL.
Changed to Orphan Well Pending 2019-03-25 Changed Well To Orphan Pending
Record Last Modified 2019-03-25 WELL WAS INSPECTED BY HAROLD MORAVY ON 4/28/2006. WELL WAS LEAKING GAS AT 100% LEL. FOUND 12 INCH BOREHOLE 8 FEET BELOW GROUND SURFACE. SET 8 INCH PVC VENT PIPE IN WELL AND BACK FILLED HOLE. NO METAL CASING IN WELL.

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1100506302 2009-06-25 Orphan No Violations Inspected vent pipe on orphan well. 5% lel out of vent. I have made 5 phone calls to Chalfant MFG. No deed has been sent to complete referral. Close case file on well.
1146396387 2006-04-28 Orphan No Violations Case # 06-004. Jay Cheslock was called by Elyria Fire department to respond to a gas leak at 7005 West River Rd in City of Elyria. I met with Asst Chief Tim Mitchell,( 440-323-4815)(440-669-4247)and Columbia Gas of Ohio representitives,Rick Hughes, (330-653-7173) at site. Gas was bubbling in the parking lot of Chalfrant Mfg. Co. Columbia brought their backhoe and we dug down 8 and located a 12 borehole leaking gas at 100 % lel. No well locaton on topo maps. We set an 8 PVC vent pipe in well and back filled hole. There is no metal casing in well.Chalfrant is applying for state funding to have well plugged. Bill Russell is the contact name.

For data sources see[3]