X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-093-21363

Well Details

Well ID: 34-093-21363
Loading map...
Country: United States
State: Ohio
County: Lorain
Municipality: Grafton Township
Operator Name: TRANSIT ENERGY INC
Well Pad ID:
Farm/Lease Name: BOY SCOUTS OF AMERICA
License Status: Producing
License Date: 1990-11-14
Spud Date: 1990-11-19
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1990-11-25
Well Total Depth: 2835.00 ft
Configuration: Vertical
Latitude: 41.200000
Longitude: -82.020000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1990-11-14 Issued Date 11/14/90 Expired Date 11/14/91 Acres 0449000 Tool Type RTAF Proposed Formation CL/TPL/MTSMN Proposed Depth 02835 Proposed Drill Depth 02835
Original Spud 1990-11-19
Completed 1990-11-25
Reached Total Depth 1990-11-25
CO 1991-01-15 627 KENOIL GeoDate 11/14/90
Completion Report Received 1991-02-19
Construction Permit Expires 1991-11-14
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 2680 2726 0
2680 2726 0
2680 2726 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 FRAC:WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 KENOIL LLC 10731.00 2541.00 365
1992 KENOIL LLC 7757.00 1204.00 365
1994 KENOIL LLC 2663.00 422.00 0
1995 KENOIL LLC 2702.00 377.00 0
1996 KENOIL LLC 2191.00 302.00 0
1997 KENOIL LLC 1271.00 220.00 365
1998 KENOIL LLC 1548.00 151.00 365
1999 KENOIL LLC 1279.00 138.00 0
2000 KENOIL LLC 1731.00 289.00 365
2001 KENOIL LLC 1549.00 231.00 365
2002 KENOIL LLC 1541.00 143.00 365
2003 KENOIL LLC 1112.00 185.00 365
2004 KENOIL LLC 1585.00 143.00 365
2005 KENOIL LLC 1332.00 215.00 365
2006 KENOIL LLC 2541.00 162.00 365
2007 KENOIL LLC 2677.00 126.00 365
2008 KENOIL LLC 1238.00 89.00 365
2009 KENOIL LLC 926.00 89.00 365
2010 KENOIL LLC 812.00 61.00 365
2011 KENOIL LLC 1112.00 91.00 0
2012 KENOIL LLC 1215.00 88.00 366
2013 KENOIL LLC 1842.00 85.00 365
2014 KENOIL LLC 1134.00 89.00 365
2015 KENOIL LLC 1293.00 63.00 365
2016 KENOIL LLC 766.00 87.00 365
2017 KENOIL LLC 358.00 32.00 365
2018 KENOIL LLC 274.00 77.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 KENOIL LLC Brine 282 365
1992 KENOIL LLC Brine 14 365
1994 KENOIL LLC Brine 9 0
1995 KENOIL LLC Brine 0 0
1996 KENOIL LLC Brine 0 0
1997 KENOIL LLC Brine 13 365
1998 KENOIL LLC Brine 7 365
1999 KENOIL LLC Brine 0
2000 KENOIL LLC Brine 35 365
2001 KENOIL LLC Brine 12 365
2002 KENOIL LLC Brine 0 365
2003 KENOIL LLC Brine 0 365
2004 KENOIL LLC Brine 19 365
2005 KENOIL LLC Brine 0 365
2006 KENOIL LLC Brine 19 365
2007 KENOIL LLC Brine 11 365
2008 KENOIL LLC Brine 0 365
2009 KENOIL LLC Brine 0 365
2010 KENOIL LLC Brine 0 365
2011 KENOIL LLC Brine 0
2012 KENOIL LLC Brine 30 366
2013 KENOIL LLC Brine 99 365
2014 KENOIL LLC Brine 24 365
2015 KENOIL LLC Brine 5 365
2016 KENOIL LLC Brine 0 365
2017 KENOIL LLC Brine 28 365
2018 KENOIL LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1951868950 2015-9-16 0:00: PW No Violations
-515563838 2014-8-6 0:00:0 PW No Violations
-598116767 2015-6-16 0:00: PW No Violations
000PL13304 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0105227445 2010-01-21 Production Wells No Violations Well in production and equipped with pump jack. 4-100 barrel tanks in battery. Approximately 1 gallon of oil around bottom of 100 barrel tank. Advised pumper to check for leaks. Contained in dike. 25 degrees, sun.
0515563838 2014-08-06 Production Wells No Violations Inspected production well on 08/06/2014. The tank battery consists of 2-100 bbl steel tanks, 1-50 bbl steel tank, and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
0598116767 2015-06-16 Production Wells No Violations Inspected production well on 06/16/2015 with Kevin Komara. The tank battery consists of 2-100 bbl steel tanks, 1-50 bbl steel tank, and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (4); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection.
105227445 2010-1-21 0:00: PW No Violations 0.50
1074005781 2004-01-13 Production Wells No Violations Well in production. Snow 30 degrees.
1947555935 2013-11-25 Production Wells No Violations Inspected production well on 11/25/2013. Tank battery consists of 2-100 bbl tanks, 1-50 bbl tank, and a separator within an earthen dike. Tank battery is used by multiple wells; well identification for all wells utilizing tank battery is posted. Wellhead is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead. There was a small amount of leakage around the slips; I spoke to Kenoil regarding this issue, and they stated that they will notify the pumper and get it addressed. No other problems were noted at the time of the inspection.
1951868950 2015-09-16 Production Wells No Violations Inspected production well on 09/16/2015. The tank battery consists of 2-100 bbl steel tanks, 1-50 bbl steel tank, and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (3); well identification is clearly displayed for all wells utilizing it. The well is equiped with a pump jack with an electric motor. Well identification is posted at the wellhead. No problems were noted at the time of the inspection.
PL13304 PL No Violations

For data sources see[9]

References