34-087-20645

Well Details

Well ID: 34-087-20645
Loading map...
Country: United States
State: Ohio
County: Lawrence
Municipality: Fayette Township
Operator Name: NYTIS EXPLORATION CO LLC
Well Pad ID:
Farm/Lease Name: LEDCO (LAWRENCE ECONOMIC DEVELOPMENT)
License Status: Final Restoration
License Date: 2006-04-03
Spud Date: 2006-12-07
Spud Drilling Contractor: TARGET DRLG
Final Drill Date: 2007-01-16
Well Total Depth: 2186.00 ft
Configuration: Vertical
Latitude: 38.420000
Longitude: -82.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-09-13 Proposed Formations:DEVONIAN SHALE, Issued Date:9/13/2005, Expired Date:9/13/2006 6:00:00 AM, Drilling unit acres:34.04, Proposed Well Type:OG, Proposed Well Class:EW
Correction to Well 2005-09-16 TARGET INFORMATION: 1687'NL & 3798'WL OF SEC. 32(S); X= 1,976,490; Y= 156,864; ELEV.= 600' (HORIZONTAL DRILL)
APP 2005-10-19 Proposed Formations:DEVONIAN SHALE, Issued Date:10/19/2005, Expired Date:10/19/2006 6:00:00 AM, Drilling unit acres:34.04, Proposed Well Type:OG, Proposed Well Class:EW
APP 2006-04-03 Proposed Formations:CLINTON, Issued Date:4/3/2006, Expired Date:4/3/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:EW
Correction to Well 2006-12-15 CHANGE IN PROPOSED GEOLOGICAL FORMATION, SHOULD BE "OHIO SHALE THRU CLINTON".
Completed 2007-01-16
Reached Total Depth 2007-01-16
Construction Permit Expires 2007-04-03
Completion Report Received 2007-06-04
Record Last Modified 2015-09-24

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0

For data sources see[3]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 NYTIS EXPLORATION CO LLC Brine 0 365
2009 NYTIS EXPLORATION CO LLC Brine 0 365
2010 NYTIS EXPLORATION CO LLC Brine 0 365
2011 NYTIS EXPLORATION CO LLC Brine 0 365
2012 NYTIS EXPLORATION CO LLC Brine 0 366
2013 NYTIS EXPLORATION CO LLC Brine 0 365
2014 NYTIS EXPLORATION CO LLC Brine 0 365
2016 NYTIS EXPLORATION CO LLC Brine 0 0
2017 NYTIS EXPLORATION CO LLC Brine 0 365

For data sources see[4] [5]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1176827083 2007-7-23 0:00: PL No Violations
-1762929540 2009-7-23 0:00: AM No Violations
-1898045268 2007-5-8 0:00:0 DD No Violations
-195894047 2006-12-13 0:00 DD No Violations
-2004928006 2007-3-14 0:00: PL No Violations
-2142897256 2008-2-28 0:00: PW No Violations
-374007436 2008-11-20 0:00 PW No Violations
-671915720 2009-12-17 0:00 PW No Violations
0126206551 2007-04-05 Drill / Deepen / Reopen Violations Noted Well casing is leaking gas, the gas can be seen bubbling up in a pool of water that is around the well. Dale Ross is still pumping the pit down. The safety fence is up around the pits. No other work has been done to the site. I called Dave ( NYTIS) on 4-5-07 and informed him of the gas leak and told him that the pit must be filled in their 30 days was up on 3-12-07. Dave told me that he is going to get Dale Ross to finish the work quickly. If not Dave said that he will hire another contractor to do the work.
0195894047 2006-12-13 Drill / Deepen / Reopen No Violations Meeting with Target drilling and TYTIS Will start drilling soon
0323293537 2010-06-14 Production Wells No Violations No fencing around the separators and plastic tanks for the #1 and # 5. I called Jeff Price and he told me that they are holding off the fence until after they plug back the #1. I asked for a letter stating a time line for the plug back and the fencing.
0360982196 2007-08-07 Production Wells No Violations Vegetative cover is good. Well does not have an identification on it or on the well site. Well is not connected to any pipeline and well is not in production yet.
0374007436 2008-11-20 Production Wells No Violations I had received a call from Dave Finley (NYTIS) and he asked if a separator could be installed at the wellhead. I told him of the spacing rules and then we discussed the problem of fencing. This is an urban well and has a good fence around it. The current fence doesnt allow enough space to install the separator inside the fence and meet the spacing requirements. They wanted to install the separator temporarily to see how much water it makes. If it is to be permanent a fence will be installed. I agreed to this because the well is located with in an industrial park. NYTIS has done a good job at following the urban rules for their two wells. I feel that they will comply if the separator is going to stay connected. I inspected the site today and found the separator out side the fence and more than 50 from the wellhead. I did not observe any problems. A plastic brine tank was located with in the fence. All connections were tight and the well was in production.
0433338946 2006-12-26 Drill / Deepen / Reopen No Violations Target Drilling is moving on site. The Drill rig is not on site yet. The rig is being worked on .
0522539841 2007-06-05 Drill / Deepen / Reopen No Violations No restoration has been done to the site after the pits were filled in. Site is rough and no vegetative cover on site. I called Dave Finley and told him that they are past their restoration deadline and that work needs to start soon. Dave told me that Dale Ross is going to move on site 6-26-07.
0541090295 2010-07-20 UrbanProduction Wells No Violations Fence has been extended around tanks and separators. No identification on gate.
0671915720 2009-12-17 Production Wells No Violations Access road has a gate at the entrance. The gate is locked. The gate has a no trespassing sign and a danger no smoking or open flame sign. The gate does not have a urban id. The well has an urban id. A mechanical separator and plastic tank is outside of the fence. There are two separators and two tanks, one for LEDCO #1 and one for LEDCO # 5. Plans have been made to fence in the production equipment and place an id on the gate.
0851242085 2007-03-21 Preliminary Restoration Violations Noted Pits are being pumped down. The safety fence around the pits is down in a few places. I called Dave Finley ( NYTIS ) He said that Ross would take care of this.
1063822261 2007-09-18 Production Wells No Violations No id. No fencing around the well site. Well is not connected to any production lines. I called Dave Finley (NYTIS) and left him a message about the Id and Fence. I requested that they submit in writing their intent to produce the well and include a time line for doing so.
1134157903 2005-12-03 Drill / Deepen / Reopen No Violations Observed drilling and placement of conductor pipe using Zugenfist rig.
1151139399 2007-07-23 Preliminary Restoration No Violations Grass is growing good. Site is in compliance with restoration rules. Well is not in production yet and has no id. There are no leaks and no violations at this time.
1168272079 2007-01-06 Drill / Deepen / Reopen No Violations Target Drilling BOP test 1st test had leaks blew down and fixed leaks. 2nd test 550psi 25min. Good test. 1500psi nitrogen. Good fire extinguishers, rig has fire suppresion system. Fire hydrant on site for water use. Flow line was only 43 has to be min. 60. They are drilling with air. Target is going to extend Flow line to 60.
1171645958 2007-02-15 Drill / Deepen / Reopen No Violations Target Drilling has moved off of the site. Pit has a fence around it. Site looks ok. I have called Nytis and left a message that I need the date that Target moved off site. So I can set the Pit closure date.
1176827083 2007-07-23 Preliminary Restoration No Violations Grass is growing good. Site is in compliance with restoration rules. Well is not in production yet and has no id. There are no leaks and no violations at this time.
1190234754 2007-09-19 Administrative Inspection No Violations I received a call from Richard Finucane (NYTIS) 606-739-9243 ext. 306. They are going to put an id on the well. They are currently working on right of ways for their pipe line. They are going with Gather Co. He said that they are working hard to get the well in production. I told Richard that they need a fence around the well.
1213640052 2008-06-09 Production Wells No Violations Excellent example of an urban site. Id is right. Fencing is correct. Good vegetative growth. All equipment is professionally installed and painted. Pipe line has been installed.
126206551 2007-4-5 0:00:0 DD No Violations
1364995102 2013-04-02 UrbanProduction Wells No Violations Accompanied Morgan Button MRI 2 on inspection of the well. Good identification on the fence. Well is producing.
1364995700 2013-04-02 UrbanProduction Wells No Violations Jon Scott took me to this well site and other LEDCO lease wells to inspect good examples of urban township production wells, urban well identification signs, fence construction, etc. I took pictures of signs and fence to use as good examples future urban well inspections. Besides the wellhead there were two 2000-gallon poly tanks to store brine and two low profile liquid/gas separators used for this well and the LEDCO #5 (API3408720670) and a small knockout tank used on the LEDCO #5 (API # 3408720670) gas production line.
1419660442 2007-07-09 Preliminary Restoration No Violations Site is seeded and mulched no vegetative cover is established yet. No production equipment has been installed yet.
1490829248 2007-05-23 Drill / Deepen / Reopen No Violations Dirt still rough no seed or mulch on site.
1762929540 2009-07-23 Administrative Inspection No Violations Called Jeff Price (NYTIS) I told Jeff that the seperator must have a fence around it to comply with urban rules. They need a gate on the lease road.
1856446970 2007-03-22 Drill / Deepen / Reopen No Violations Met Dale Ross ( Sub-contractor for NYTIS ) He is pumping the pits and he has fixed the safety fence around the pits.
1898045268 2007-05-08 Drill / Deepen / Reopen No Violations Site needs to be graded and seeded and mulched. Ground is dry. No id or fencing on site. No production equipment on site.
1981020747 2007-04-17 Drill / Deepen / Reopen No Violations Pit is filled in. Gravel has been placed around the wellhead. Cannot detect gas leak at this time. Center of pit is GPS +/- 10 N38.42778 W082.58817.
2004928006 2007-03-14 Preliminary Restoration No Violations The pit is being pumped down. They are not done yet. Ross is pumping it down. Safety fence is down in several places. I am going to call the company and request that they inform me when the pit is going to be closed.
2127938614 2007-01-18 Drill / Deepen / Reopen No Violations Frac tank being pumped out. Every looks ok at this time.
2142897256 2008-02-28 Production Wells No Violations Well is not connected to the main line. The line is being installed at this time. The location looks good. The id and fencing will be installed after the well is connected to the main line. Production equipment is on site.
323293537 2010-6-14 0:00: PW No Violations 0.70
360982196 2007-8-7 0:00:0 PW No Violations
433338946 2006-12-26 0:00 DD No Violations
522539841 2007-6-5 0:00:0 DD No Violations
541090295 2010-7-20 0:00: UP No Violations
851242085 2007-3-21 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0126206551 US-OH-107065 2007-04-09 Failure to comply with permit conditions
0851242085 US-OH-129683 2007-03-21 General Safety

For data sources see[6]