Well Details

Well ID: 34-085-21207
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PETRO EVALUATION SERVICES INC
Well Pad ID:
Farm/Lease Name: MENTOR HEIGHTS
License Status: Producing
License Date: 2006-06-13
Spud Date: 2006-07-25
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-08-03
Well Total Depth: 3397.00 ft
Configuration: Vertical
Latitude: 41.660000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-06-13 Proposed Formations:CLINTON, Issued Date:6/13/2006, Expired Date:6/13/2007 6:00:00 AM, Drilling unit acres:20.2, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2006-06-16 CORRECTION TO FOOTAGE, SHOULD BE "FROM NE CORNER OF LOT 1, SHEHI TRACT, GO NORTH 49' THEN WEST 317' (IN RUSSELL LOT).
Completed 2006-08-03 RBDMS Rec
Reached Total Depth 2006-08-03 RBDMS Rec
Completion Report Received 2007-02-14 RBDMS Rec
Construction Permit Expires 2007-06-13 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-05-16 3178 3230 15
3178 3230 15
3178 3230 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1200 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 PETRO EVALUATION SERVICES INC 24755.00 594.00 361
2008 PETRO EVALUATION SERVICES INC 37445.00 753.00 365
2009 PETRO EVALUATION SERVICES INC 28590.00 375.00 365
2010 PETRO EVALUATION SERVICES INC 24683.00 384.00 365
2011 PETRO EVALUATION SERVICES INC 16814.00 283.00 365
2012 PETRO EVALUATION SERVICES INC 13215.00 268.00 366
2013 PETRO EVALUATION SERVICES INC 9859.00 246.00 365
2014 PETRO EVALUATION SERVICES INC 8367.00 186.00 365
2015 PETRO EVALUATION SERVICES INC 7789.00 268.00 365
2016 PETRO EVALUATION SERVICES INC 7653.00 181.00 365
2017 PETRO EVALUATION SERVICES INC 5600.00 71.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 PETRO EVALUATION SERVICES INC Brine 225 361
2008 PETRO EVALUATION SERVICES INC Brine 588 365
2009 PETRO EVALUATION SERVICES INC Brine 705 365
2010 PETRO EVALUATION SERVICES INC Brine 499 365
2011 PETRO EVALUATION SERVICES INC Brine 210 365
2012 PETRO EVALUATION SERVICES INC Brine 345 366
2013 PETRO EVALUATION SERVICES INC Brine 200 365
2014 PETRO EVALUATION SERVICES INC Brine 345 365
2015 PETRO EVALUATION SERVICES INC Brine 255 365
2016 PETRO EVALUATION SERVICES INC Brine 380 365
2017 PETRO EVALUATION SERVICES INC Brine 180 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1097453184 2006-9-19 0:00: DD No Violations
0068318365 2017-06-16 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery located within a commercial nursery facility. Fittings at the wellhead and tank battery were secure and free from signs of leakage or problems. Tank lids were closed. Load lines were closed, plugged and secure. The was intact secondary containment which was dry and free from any significant signs of spills, leakage, or other problems. I walked the areas surrounding the well and battery and observed grassy and wooded areas with no signs of impact or degradation to the natural greenscape. The gravel-paved access road was in good condition with no erosional deficits. Production data was current and there were no indications of problems or deficiencies regarding bonding and insurance. I did note the following deficiencies: the well was permitted and drilled after promulgation of the rules for urban drilling. As such, the well must be fitted with the following: low-pressure relief valve, spark arrestor, carbon filter, and lid capable of being sealed. I contacted the owner and advised them about the deficiencies. A response was pending at the time of this report filing.
0395744973 2012-11-26 UrbanProduction Wells No Violations The unit consists of a 2-tank battery (TB) with mechanical seperator enclosed in a 4-foot, split-rail fence. The spacing is in accordance with the rule, and the valving and mechanicals are in good repair. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a concoil lift and is located 50 feet north of the east. The tank battery dike is low. I called Steve Franks of Petro Evaluation and told him about the need for repair to the dike. I asked that the repairs be made in the next month.
1097453184 2006-09-19 Drill / Deepen / Reopen No Violations revising tank battery location revised plat sent inon same property moving to west of original spot
1130765272 2020-6-26 0:00: UP No Violations
1156945865 2006-07-27 Drill / Deepen / Reopen No Violations surface casing job
1382265391 2014-07-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 08/03/2006. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and concoil production system. The wellhead and battery are located down an access road which is shared with access to portions of the Wilson Nursery facility. The access portion is graveled and in reasonable condition. There are no signs of leakage or problems at the wellhead. The battery is comprised of a total of 1 steel 140-barrel production tank, 1 50-barrel poly brine tank, and horizontal separator. Spacing from well to battery, and spacing of elements within the battery meet regulations. The battery and wellhead are located in separate split-rail fence enclosures. The load-outs are bull-plugged. The secondary containment at the battery is present. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery which is legible and in good condition.
1531755639 2018-07-16 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: Fittings at the wellhead and tank battery were secure and free from signs of leakage or problems. The well was in active production with active chart record. The tank lids were closed. Load lines were closed, plugged and secure. I walked the areas surrounding the well and battery and observed grassy and wooded areas with no signs of impact or degradation to the natural greenscape.
1570667272 2010-08-10 Preliminary Restoration No Violations Preliminary restoration was found to be complete and adequate.
325237285 2019-11-19 0:00 UP No Violations
395744973 2012-11-26 0:00 UP No Violations
68318365 2017-6-16 0:00: UP No Violations 0.50

For data sources see[9]