X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21202

Well Details

Well ID: 34-085-21202
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: SMITTY
License Status: Producing
License Date: 2006-06-05
Spud Date: 2006-09-29
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-10-05
Well Total Depth: 3280.00 ft
Configuration: Vertical
Latitude: 41.690000
Longitude: -81.230000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-06-05 Proposed Formations:CLINTON, Issued Date:6/5/2006, Expired Date:6/5/2007 6:00:00 AM, Drilling unit acres:21.72, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-10-05 RBDMS Rec
Reached Total Depth 2006-10-05 RBDMS Rec
Completion Report Received 2007-01-16 RBDMS Rec
Construction Permit Expires 2007-06-05 RBDMS Rec
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-03-28 3093 3122 25
3093 3122 25
3093 3122 25

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 20056 Gal 100500

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 2931.00 0.00 68
2007 JOHN D OIL & GAS COMPANY 7192.00 0.00 365
2008 JOHN D OIL & GAS COMPANY 3002.00 42.00 365
2009 JOHN D OIL & GAS COMPANY 2647.00 0.00 365
2010 JOHN D OIL & GAS COMPANY 1274.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 1290.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 1097.00 0.00 366
2013 JOHN D OIL & GAS COMPANY 716.00 0.00 365
2014 JOHN D OIL & GAS COMPANY 539.00 0.00 365
2015 JOHN D OIL & GAS COMPANY 469.00 0.00 365
2016 DAVID OIL COMPANY LLC 0.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 0 68
2007 JOHN D OIL & GAS COMPANY Brine 1030 365
2008 JOHN D OIL & GAS COMPANY Brine 460 365
2009 JOHN D OIL & GAS COMPANY Brine 160 365
2010 JOHN D OIL & GAS COMPANY Brine 320 365
2011 JOHN D OIL & GAS COMPANY Brine 560 365
2012 JOHN D OIL & GAS COMPANY Brine 240 366
2013 JOHN D OIL & GAS COMPANY Brine 240 365
2014 JOHN D OIL & GAS COMPANY Brine 320 365
2015 JOHN D OIL & GAS COMPANY Brine 160 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1164510208 2020-9-25 0:00: UP No Violations
-176760922 2016-2-19 0:00: UP No Violations
-1851020834 2007-11-8 0:00: PL No Violations
0044733605 2017-08-03 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice. At the time of the previous inspection, I had noted the following: the load-line valves were not secure with locks, the brine tank was perforated with numerous holes, and the tanks were missing carbon filter and spark arrestor. At the time of this inspection, the noted deficiencies remain. In addition, the signage has not been updated to reflect the change of ownership that occurred in 12/2016. I contacted John Magnussen with David Oil who indicated that the issues are being handled as they are able. I inspected the wellhead and surrounding area and found no signs of problems otherwise.
0176760922 2016-02-19 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of one 210-barrel steel storage tank, one 100-barrel steel tank, with mechanical separator. The battery and wellhead are not enclosed. The 100-barrel tank is severely corroded with complete perforations in many spots. Fittings and connections are free from leakage. The production tank did not have a spark arrestor, a low-pressure relief valve, or carbon filter as required. The tank lid was closed and sealed. The dedicated access road is in good condition. The load-line valves were not locked and must be secured with locks. The tank battery and wellhead must be secured in separate, locked enclosures as required under 1501:9-9-05(E)(2). The owner must remedy the following by 03/25/2016: secure the load-line valves with locks, enclose the wellhead and battery as required under OAC 1501:9-9-05(E)(2). Replace the tank which has lost integrity due to corrosion. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
1198518855 2007-12-12 Preliminary Restoration No Violations
1425942163 2017-12-11 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the 210-production tank was rusted and lost integrity, there was no spark arrestor, low-pressure relief valve, or carbon filter, the load-line valves were not locked and secure, and there was not fencing or enclosure at the wellhead or battery. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, the unit signage had not been updated since the change of owner that had occurred in 2016. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
1566485452 2019-8-22 0:00: UP No Violations
1581700825 2020-2-14 0:00: UP No Violations
1851020834 2007-11-08 Preliminary Restoration No Violations
44733605 2017-8-3 0:00:0 UP No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0176760922 US-OH-117585 2016-04-27 FENCING (a-d)
0176760922 US-OH-117586 2016-04-27 LOCKS
0176760922 US-OH-117587 2016-04-27 TANKS (a-i)
0176760922 US-OH-117588 2016-04-27 Well insufficiently equipped to prevent escape of oil and gas

For data sources see[9]

References