X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21188

Well Details

Well ID: 34-085-21188
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: GREG JR
License Status: Producing
License Date: 2006-01-27
Spud Date: 2006-02-12
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-02-18
Well Total Depth: 3589.00 ft
Configuration: Vertical
Latitude: 41.650000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-01-27 Proposed Formations:CLINTON, Issued Date:1/27/2006, Expired Date:1/27/2007 6:00:00 AM, Drilling unit acres:20.569, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-02-12
Completed 2006-02-18
Reached Total Depth 2006-02-18
Completion Report Received 2006-11-13
Construction Permit Expires 2007-01-27
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-01-14 3354 3373 15
3354 3373 15
3354 3373 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 557 Bbl 120000 690M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY 13081.00 0.00 299
2007 JOHN D OIL & GAS COMPANY 10446.00 60.00 365
2008 JOHN D OIL & GAS COMPANY 6691.00 21.00 365
2009 JOHN D OIL & GAS COMPANY 6577.00 15.00 365
2010 JOHN D OIL & GAS COMPANY 4708.00 0.00 365
2011 JOHN D OIL & GAS COMPANY 3398.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 1227.00 0.00 366
2015 GREAT PLAINS EXPLORATION LLC 0.00 0.00 365
2016 DAVID OIL COMPANY LLC 0.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 JOHN D OIL & GAS COMPANY Brine 1260 299
2007 JOHN D OIL & GAS COMPANY Brine 1180 365
2008 JOHN D OIL & GAS COMPANY Brine 800 365
2009 JOHN D OIL & GAS COMPANY Brine 1120 365
2010 JOHN D OIL & GAS COMPANY Brine 960 365
2011 JOHN D OIL & GAS COMPANY Brine 640 365
2012 JOHN D OIL & GAS COMPANY Brine 480 366
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1467259863 2017-5-5 0:00:0 UP No Violations 0.50
-1889978325 2017-12-5 0:00: UP No Violations
-297958632 2010-4-6 0:00:0 PL No Violations
-325730839 2015-4-22 0:00: UP No Violations 0.50
-384642868 2006-11-15 0:00 PL No Violations
-540851583 2015-9-15 0:00: UP No Violations 0.50
-920357544 2020-7-28 0:00: UP No Violations
0297958632 2010-04-06 Preliminary Restoration No Violations Preliminary restoration was completed.
0325730839 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located in a open, grassy portion on a open, undeveloped area within a newer residential subdivision. The well is comprised of a mechanical plunger-lift system in a board-on-board enclosure which is locked. Fittings and connections at the wellhead are secure. The battery is comprised of one 210-barrel steel production tank and one 100-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings are secure however I observed a recent release of oil within the diked area which has not been addressed. There is approximately 1 barrel of oil floating on water within the battery and staining the containment ballast. I inspected the areas outside the dike and observed some oil staining to the grass on the north side of the dike, but no free oil beyond the dike. I also walked to the creek which lie at the bottom of the ravine adjacent to the well and did not observe any oil. I contacted John Magnusson with John D Oil and advised him about the oil in the dike. He indicated no knowledge of a release and would be sending a crew ASAP. (The battery is shared with the Acacia Unit #2-1126).
0384642868 2006-11-15 Preliminary Restoration No Violations
0540851583 2015-09-15 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well is located in a newer residential development. along Girdled Road, east of SR 44. The well is on a upper hillslope behind a single-family home, and is accessed via a separate, dedicated unpaved drive. The well is located within a board-on-board enclosure. There is a lock present but it is non-functional. Fittings and connections at the well are secure and free from leakage or problems. The battery is shared with the #2-1126 (Acacia). The battery is accessed at the end of Viceroy Dr. The battery enclosure gate is secure. Load-lines are secure and bull-plugged. Fittings and connections at the battery are secure and free from leakage. I contacted the well owner and advised to replace the lock
0888719049 2018-04-17 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and unit identification remained from the prior owner and did not have current, accurate information. At the time of this inspection, I observed the following: there were no locks at the load-line valves, or enclosure gates. The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies.
0937760623 2013-07-25 UrbanProduction Wells No Violations The producing unit consists of a wellhead and mechanical plunger-lift unit and an aboveground storage tank (AST) battery with one steel 210-barrel production tank, one steel 140-barrel brine tank, mechanical separators in separate board-on-board enclosures. The unit ID is present and meets requirements. The loadouts are locked. The battery secondary containment is good. The battery is shared with the Acacia unit (#21126). Saftey equipment is present in accordance with 1501:9-9-05E. The wellhead is lacking an ID placard. I advised Chris with John D. Oil that ande ID is required. He indicated that he would address as soon as possible.
1168441528 2019-6-18 0:00: UP No Violations
1467259863 2017-05-05 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves. At the time of this inspection, I observed the following: The wellhead was comprised of a plunger-lift system with associated tank battery (shared with the #2-1126) well. The load-line valves were not secured with locks. In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). I have contacted John Magnussen about the unaddressed deficiencies and he advised that the compliance issues are being tended to as soon as possible. I also attempted to contact Richard Osborne Sr. and, as of the filing of this report, he has not responded to multiple messages.
1518555705 2018-02-13 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, and unit identification remained from the prior owner and did not have current, accurate information. At the time of this inspection, I observed the following: the were no locks at the load-line valves. The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies.
1889978325 2017-12-05 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked. At the time of this inspection, I observed the following: there were no locks at the load-line valve or on the mechanical separator enclosure. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. The board-on-board enclosure at the wellhead had been removed. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
2032570139 2016-02-09 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well is located behind the house at this location. The battery is accessed at the end of Viceroy. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in a board-on-board enclosure. Fittings and connections at the wellhead were secure. The battery is comprised of one 210-barrel steel production tank, one 100-barrel steel brine tank and separator in separate board-on-board enclosures. Enclosure gates were locked and secure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present. I noted the following safety issues: The load-line valves were not locked. The owner must remedy the following by 04/08/2016: secure the load-line valves with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
888719049 2018-4-17 0:00: UP No Violations 0.50
937760623 2013-7-25 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2032570139 US-OH-120662 2016-06-01 LOCKS

For data sources see[9]

References