34-085-21149

Well Details

Well ID: 34-085-21149
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: KNIGHT
License Status: Producing
License Date: 2005-06-06
Spud Date: 2005-11-03
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-11-09
Well Total Depth: 3278.00 ft
Configuration: Vertical
Latitude: 41.710000
Longitude: -81.260000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-04-19 Proposed Formations:CLINTON, Issued Date:4/19/2005, Expired Date:4/19/2006 6:00:00 AM, Drilling unit acres:25.77, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2005-06-06 Proposed Formations:CLINTON, Issued Date:6/6/2005, Expired Date:6/6/2006 6:00:00 AM, Drilling unit acres:27.63, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-11-03 RBDMS Rec
Completed 2005-11-09 RBDMS Rec
Reached Total Depth 2005-11-09 RBDMS Rec
Completion Report Received 2006-03-21 RBDMS Rec
Construction Permit Expires 2006-06-06 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-06-14 3018 3028 13
3018 3028 13
3018 3028 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 448 Bbl 100000 492M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 GREAT PLAINS EXPLORATION LLC 4243.00 0.00 58
2006 GREAT PLAINS EXPLORATION LLC 20417.00 5.00 365
2007 GREAT PLAINS EXPLORATION LLC 14747.00 0.00 365
2008 GREAT PLAINS EXPLORATION LLC 12872.00 45.00 365
2009 GREAT PLAINS EXPLORATION LLC 15531.00 0.00 365
2010 GREAT PLAINS EXPLORATION LLC 13891.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 16006.00 0.00 365
2012 GREAT PLAINS EXPLORATION LLC 13452.00 0.00 366
2013 GREAT PLAINS EXPLORATION LLC 11316.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 9841.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 6173.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 374.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 GREAT PLAINS EXPLORATION LLC Brine 0 58
2006 GREAT PLAINS EXPLORATION LLC Brine 680 365
2007 GREAT PLAINS EXPLORATION LLC Brine 550 365
2008 GREAT PLAINS EXPLORATION LLC Brine 950 365
2009 GREAT PLAINS EXPLORATION LLC Brine 620 365
2010 GREAT PLAINS EXPLORATION LLC Brine 520 365
2011 GREAT PLAINS EXPLORATION LLC Brine 480 365
2012 GREAT PLAINS EXPLORATION LLC Brine 400 366
2013 GREAT PLAINS EXPLORATION LLC Brine 310 365
2014 GREAT PLAINS EXPLORATION LLC Brine 210 365
2015 GREAT PLAINS EXPLORATION LLC Brine 462 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1026065217 2005-11-5 0:00: DD No Violations
-1378198055 2009-4-6 0:00:0 PW No Violations
-1805734383 2017-4-6 0:00:0 UP No Violations 0.50
-454397941 2013-7-15 0:00: UP No Violations
-513470475 2016-2-19 0:00: UP No Violations 0.50
-538363718 2017-12-12 0:00 UP No Violations 0.50
-586502797 2011-8-16 0:00: UP No Violations
-594776885 2019-11-4 0:00: UP No Violations
-754626116 2017-9-19 0:00: UP No Violations 1.00
0454397941 2013-07-15 UrbanProduction Wells No Violations The producing unit consists of a wellhead and mechanical plunger-lift unit and an aboveground storage tank (AST) battery with one steel 210-barrel production tank and mechanical separator. There are no enclosures. The unit ID is present and meets requirements. The loadouts are not locked. The battery secondary containment is good. I contacted Tim Reilly with Great Plains and advised about the need for locks on the loadouts.
0513470475 2016-02-19 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with mechanical plunger lift and tank battery consisting of one 210-barrel steel storage tank, with mechanical separator. The battery and wellhead are not enclosed. Fittings and connections are free from leakage. The tank lid was closed and sealed. The dedicated access road is in good condition. The load-line valves were not locked and must be secured with locks. The owner must remedy the following by 03/25/2016: secure the load-line valves with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
0538363718 2017-12-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: The load-lines were no locked and secure. At the time of this inspection, I observed the following: the noted deficiencies remained. In addition, I noted that the wellhead and battery were not in enclosures as required. I had previously contacted the company about the deficiencies and they had reported various issues regarding lack of personnel and funds preventing them from being in compliance.
0586502797 2011-08-16 UrbanProduction Wells No Violations Lease road stable, gate is locked. Dike and spacing in compliance. ID sign posted. Vent hatches are installed and closed. No violations at this time.
0754626116 2017-09-19 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: The load lines were noted to be unlocked and unsecure. At the time of this inspection, the load-line valves remained unsecure. In addition, the ID signage remained unchanged and had not been updated to reflect the change in ownership that had occurred in 2016. Repeated calls to the owner have not produced any demonstrable action or results.
1026065217 2005-11-05 Drill / Deepen / Reopen No Violations
1181141171 2007-04-16 Preliminary Restoration No Violations
1217056005 2005-11-06 Drill / Deepen / Reopen No Violations surface 85/8
1378198055 2009-04-06 Production Wells No Violations no violation
1416468820 2005-05-18 Drill / Deepen / Reopen No Violations making location
1425653476 2015-03-06 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and battery are located in a residential area along Jackson Street in Painesville. The dedicated lease road adjacent to the house at the referenced address The wellhead plunger lift system and battery are located in an open area behind houses. The wellhead and battery are not in enclosures. Connections and fittings are secure and free from signs of leakage or problems. Load-outs are plugged and secure but are not locked which was noted and reported to Great Plains at the last inspection. Areas around the wellhead and battery are snow-covered at the time of this inspection. I notified Great Plains a second time about the need for locks at the load-out. I did not observe any evidence of impact relating to on-going production activity.
1798642713 2005-05-23 Drill / Deepen / Reopen No Violations Making location dug test pit hit water and sand.
1805734383 2017-04-06 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of this inspection, I found the following: Fittings and connections at the wellhead were secure and free from leakage. The tank battery was comprised of a 210-barrel steel production tank with separator unit located in the rear portion of a parcel which was largely undeveloped, but utilized for stockpiling of bricks and other debris. Load-lines remained unsecure with locks as required. The ID signage remains not updated to reflect the new owner. I contacted John Magnussen with David Oil and advised him about the continuing deficiency. He indicated that the items are being worked on as they are able. I contacted Richard Osborne Sr. with David Oil Co., and as of the date of this report, I have not received a response.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0513470475 US-OH-125605 2016-04-27 LOCKS