34-085-21144

Well Details

Well ID: 34-085-21144
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: WARNER NURSERIES INC
License Status: Producing
License Date: 2005-03-04
Spud Date: 2005-03-05
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2005-03-10
Well Total Depth: 3292.00 ft
Configuration: Vertical
Latitude: 41.580000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-03-04 Proposed Formations:CLINTON/MEDINA, Issued Date:3/4/2005, Expired Date:3/4/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:EW
Original Spud 2005-03-05 RBDMS Rec
Completed 2005-03-10 RBDMS Rec
Reached Total Depth 2005-03-10 RBDMS Rec
Completion Report Received 2005-05-18 RBDMS Rec
Construction Permit Expires 2006-03-04 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-07-25 3120 3163 39
3120 3163 39
3120 3163 39

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 68000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 OHIO L & M CO INC 1660.00 348.00 124
2006 ALLIANCE PETROLEUM CORPORATION 3971.00 235.00 365
2007 ALLIANCE PETROLEUM CORPORATION 741.00 228.00 365
2008 ALLIANCE PETROLEUM CORPORATION 1600.00 267.00 365
2009 ALLIANCE PETROLEUM CORPORATION 997.00 192.00 365
2010 ALLIANCE PETROLEUM CORPORATION 201.00 183.00 365
2011 ALLIANCE PETROLEUM CORPORATION 1519.00 165.00 365
2012 ALLIANCE PETROLEUM CORPORATION 2739.00 242.00 366
2013 ALLIANCE PETROLEUM CORPORATION 1526.00 209.00 365
2014 ALLIANCE PETROLEUM CORPORATION 1140.00 184.00 365
2015 ALLIANCE PETROLEUM CORPORATION 2025.00 182.00 365
2016 ALLIANCE PETROLEUM CORPORATION 1412.00 228.00 365
2017 ALLIANCE PETROLEUM CORPORATION 648.00 168.00 365
2018 ALLIANCE PETROLEUM CORPORATION 72.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 OHIO L & M CO INC Brine 0 124
2006 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 516 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 252 365
2015 ALLIANCE PETROLEUM CORPORATION Brine 345 365
2016 ALLIANCE PETROLEUM CORPORATION Brine 196 365
2017 ALLIANCE PETROLEUM CORPORATION Brine 256 365
2018 ALLIANCE PETROLEUM CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1242631348 2005-3-21 0:00: PW No Violations
-159457687 2009-10-22 0:00 PW No Violations
-358289733 2005-11-7 0:00: PW No Violations
-753357306 2016-3-7 0:00:0 UP No Violations 1.00
0159457687 2009-10-22 Production Wells No Violations There were no violations at the time.
0179341800 2011-06-13 UrbanProduction Wells No Violations Wellhead is a pumpjack in good repair. Wellhead is fenced and locked. Tank battery contains 2-100 bbl production tanks, spacing is good, dike is good. Fence in place and gate locked. Vent hatches installed and closed. ID signs in place. Dike is good. Feed lines are bullplugged. Lease road is stable. Site is pre HB278. No violations at this time.
0279968949 2005-06-29 Preliminary Restoration No Violations
0358289733 2005-11-07 Production Wells No Violations
0459260467 2014-08-13 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 03/10/2005. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and pump jack system and aboveground storage tank (AST) battery. The wellhead and surrounding area are free of signs of leaks or other impacts. The wellhead is located across from the Lake Metro Parks Pleasant Valley Park between Pleasant Valley Road and the Chagrin River. The area surround the wellhead and battery is wooded. Access to the wellhead is via a dedicated gravel access road which travels north from Pleasant Valley Road, and passes the well in 300 before looping back to the main road. The battery is located south of Pleasant Valley Road via a similar gravel access road which also accesses the Metro Park parking. The battery is comprised of 1 steel 100-barrel production tank, 1 100-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. The interior portion of the battery is overgrown with vegetation. I did not observe any signs or evidence of leakage, spills, or problems. Surface drainage from the area is towards the Chagrin River, 400 feet north. I did not observe any gully formation or other surface drainage erosional deficits. The ID placards at the wellhead and battery are in good condition. I notified Alliance about the vegetation overgrowth in the battery.
0704126377 2005-03-09 Drill / Deepen / Reopen No Violations drilling 3180Newburgh watered out.
0753357306 2016-03-07 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. I observed the following elements: a wellhead with electrical pump jack system in a chain-link enclosure and accessed via a short, dedicated, unpaved access road that enters from Pleasant Valley Road, a battery comprised of two, 100-barrel, steel tanks, and separator in a chain-link enclosure, accessed from a separate, unpaved access road on the south side of Pleasant Valley Road. The well ID signage was present. Load-line valves were plugged and locked. Secondary containment was intact. Tank lids were closed and secure. The enclosure gates were locked. At the time of this inspection, I noted the following: some oil leakage had occurred from the stuffing box causing some minor staining to the surrounding well structure. I also noted some oil leakage from the 3-inch cross-over line at the tank battery had occurred. The system was otherwise free from problems. I contacted Alliance Supervisor Matt Postlethwaite and advised him about the need for maintenance at the stuffing box and cross-over line.
1081288039 2009-04-07 Preliminary Restoration No Violations
1112144547 2005-02-25 Drill / Deepen / Reopen No Violations well site inspection.
1126100752 2005-08-05 Production Wells No Violations
1242631348 2005-03-21 Production Wells No Violations pits open dewating to close
1244199923 2012-01-18 UrbanProduction Wells No Violations
1308241465 2011-06-13 UrbanProduction Wells No Violations Tank battery contains 2-210 bbl production tanks. Dike is good, spacing is good. Lease road is stable. ID signs in place. Fencing in place, gate locked. Feed lines are bullplugged. Vent hatches are installed and closed. Wellhead is a pumpjack in good repair. No violations at this time.
1339871038 2005-04-07 Production Wells No Violations Pits closed no violation
1511987940 2017-11-29 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and battery are located on a largely undeveloped parcel. At the time of this inspection, I found the following: a wellhead pump-jack unit and associated battery in separate chain-link enclosures. The fittings and connections were secure and free from leakage or problems. Fittings and connections at the battery were secure. The load-lines were plugged and locked. ID signage was present and current. The secondary containment was intact with no signs of leakage, spills, or problems. Oil leakage that I had noted during a previous inspection at the stuffing box and the 3-inch cross-over line was remedied. The shared-use access road was in good condition. Production reports along with insurance and bonding were current.
1588612401 2020-5-4 0:00:0 UP No Violations
1747869490 2019-10-3 0:00: UP No Violations
179341800 2011-6-13 0:00: UP No Violations 0.50
279968949 2005-6-29 0:00: PL No Violations
459260467 2014-8-13 0:00: UP No Violations
704126377 2005-3-9 0:00:0 DD No Violations

For data sources see[9]

References