X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-21126

Well Details

Well ID: 34-085-21126
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Concord Township
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: ACACIA
License Status: Producing
License Date: 2005-11-29
Spud Date: 2005-12-09
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-12-15
Well Total Depth: 3591.00 ft
Configuration: Vertical
Latitude: 41.650000
Longitude: -81.220000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-11-02 Proposed Formations:CLINTON, Issued Date:11/2/2004, Expired Date:11/2/2005 6:00:00 AM, Drilling unit acres:91.92, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2005-11-29 Proposed Formations: CLINTON, Issued Date:11/29/2005, Expired Date:11/29/2006 6:00:00 AM, Drilling unit acres:91.92, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-12-09 RBDMS Rec
Completed 2005-12-15 RBDMS Rec
Reached Total Depth 2005-12-15 RBDMS Rec
Correction to Well 2006-01-27 UNIT REDUCED TO 24.379 ACRES.
Completion Report Received 2006-03-21 RBDMS Rec
Construction Permit Expires 2006-11-29 RBDMS Rec
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-06-14 3348 3358 13
3348 3358 13
3348 3358 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 495 Bbl 100000 618M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 GREAT PLAINS EXPLORATION LLC 29932.00 0.00 365
2007 GREAT PLAINS EXPLORATION LLC 25651.00 60.00 365
2008 GREAT PLAINS EXPLORATION LLC 17016.00 21.00 365
2009 GREAT PLAINS EXPLORATION LLC 14531.00 15.00 365
2010 GREAT PLAINS EXPLORATION LLC 7350.00 0.00 365
2011 GREAT PLAINS EXPLORATION LLC 6687.00 0.00 365
2012 GREAT PLAINS EXPLORATION LLC 6760.00 0.00 366
2013 GREAT PLAINS EXPLORATION LLC 7021.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 6929.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 3662.00 0.00 365
2016 ROCKEFELLER OIL COMPANY LLC 271.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 GREAT PLAINS EXPLORATION LLC Brine 860 365
2007 GREAT PLAINS EXPLORATION LLC Brine 1560 365
2008 GREAT PLAINS EXPLORATION LLC Brine 1380 365
2009 GREAT PLAINS EXPLORATION LLC Brine 1460 365
2010 GREAT PLAINS EXPLORATION LLC Brine 1170 365
2011 GREAT PLAINS EXPLORATION LLC Brine 880 365
2012 GREAT PLAINS EXPLORATION LLC Brine 320 366
2013 GREAT PLAINS EXPLORATION LLC Brine 240 365
2014 GREAT PLAINS EXPLORATION LLC Brine 300 365
2015 GREAT PLAINS EXPLORATION LLC Brine 452 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1246882659 2020-7-28 0:00: UP No Violations
-1752317045 2018-12-3 0:00: UP No Violations
-203438610 2005-12-7 0:00: PL No Violations
-641896138 2017-5-5 0:00:0 UP No Violations 0.50
-823819888 2017-12-5 0:00: UP No Violations 1.00
-92849503 2019-6-7 0:00:0 UP No Violations
0203438610 2005-12-07 Preliminary Restoration No Violations
0372550150 2018-02-13 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: no locks at the load-line valves, and severe rusting/corrosion of the 210-barrel production tank. At the time of this inspection, I observed the following: the were no locks at the load-line valves and the 210-barrel tank remains in place, but was not being actively produced into. The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies.
0384170973 2006-11-15 Preliminary Restoration No Violations
0641896138 2017-05-05 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued compliance notice for the following: missing locks at the load-line valves. At the time of this inspection, I observed the following: The wellhead was comprised of a plunger-lift system with associated tank battery (shared with the #2-1188) well. The load-line valves were not secured with locks. In addition, the ID signage has not been upgraded to reflect the change in ownership and is missing information required under OAC 1501:9-9-05(E)(1). I have contacted John Magnussen about the unaddressed deficiencies and he advised that the compliance issues are being tended to as soon as possible. I also attempted to contact Richard Osborne Sr. and, as of the filing of this report, he has not responded to multiple messages.
0733548168 2015-04-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located in a open, grassy portion on a open, undeveloped area within a newer residential subdivision. The well is comprised of a mechanical plunger-lift system in a board-on-board enclosure which is locked. Fittings and connections at the wellhead are secure. The battery is comprised of one 210-barrel steel production tank and one 100-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings are secure however I observed a recent release of oil within the diked area which has not been addressed. There is approximately 1 barrel of oil floating on water within the battery and staining the containment ballast. I inspected the areas outside the dike and observed some oil staining to the grass on the north side of the dike, but no free oil beyond the dike. I also walked to the creek which lie at the bottom of the ravine adjacent to the well and did not observe any oil. I contacted John Magnusson with John D Oil and advised him about the oil in the dike. He indicated no knowledge of a release and would be sending a crew ASAP.
0823819888 2017-12-05 UrbanProduction Wells Violations Noted I inspected this well location as a follow-up to a previously-issued compliance notice issued for unsecured load-line locks. At the time of this inspection, I observed the following additional deficiency: the 210-barrel steel stock tank, which is shared with the #2-1188 (Greg 13) was observed to have serious and substantial corrosion of the sidewalls resulting in failure of the tank integrity. The tank must be taken out of service immediately, and removed from the production system within 30 days. Contact Inspector Stephen Tompkins (330-907-4647) with any questions regarding this compliance notice.
1202965778 2017-12-05 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked. At the time of this inspection, I observed the following: there were no locks at the load-line valve or on the mechanical separator enclosure. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
1314083623 2017-09-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. At the time of this inspection, the indicated deficiency had not been remedied. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. Repeated calls to the owner have not produced any demonstrable action or results.
1374771174 2013-07-25 UrbanProduction Wells No Violations The producing unit consists of a wellhead and mechanical plunger-lift unit and an aboveground storage tank (AST) battery with one steel 210-barrel production tank, one steel 140-barrel brine tank, mechanical separators in separate board-on-board enclosures. The unit ID is present and meets requirements. The load-outs are locked. The battery secondary containment is good. The battery is shared with the Greg Jr. unit (#21188). Saftey equipment is present in accordance with 1501:9-9-05E. No problems or violations noted.
1430489439 2015-05-01 UrbanProduction Wells Violations Noted I inspected this producing unit as a follow-up to an earlier inspection on 04/22/2015 whereby I observed a release of 0.5 to 1 barrel of crude oil into the secondary containment of the tank battery. At the time of that inspection I immediately notified John Magnuson with Great Plains Exploration who indicated the issue would be addressed ASAP. As of this date, acted John Magnuson and have advised that clean-up must include removal of at the majority of the oil released remains along with all of the oil-impacted dike gravel-ballast and all free oil and oil-impacted dike ballast and berm material. As a follow-up I was contacted by Matt Lutta with Great Plains regarding the incident. Matt and his crew arrived at the location at 1150 AM to begin mitigation and clean-up. I advised Matt that clean-up will not be considered complete until all residual oil and oil-impacted material has been removed or cleaned to the maximum extent practicable. These activities should be completed within 30 days or be subject to additional enforcement action.
1442339968 2015-09-15 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued Compliance Notice relating to a release of oil which had occurred within the confines of the secondary containment. At the time of the incident, approximately 1 barrel of oil had been released into the containment from an over-fill situation. At my original inspection, I did not observe an oil or oil-related impact outside the containment for the tank battery. At the time of this inspection, the oil has been recovered and the interior of the containment has been restored. Actions necessary to complete the remedy are complete. The lease road gate is lacking signage and Ive contacted the owner to remedy.
1716055014 2019-11-19 0:00 UP No Violations
1752317045 2018-12-03 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 823819888, regarding the removal of the 100 BBL tank due to loss of integrity. The well was a plunger lift assembly and not in production at the time of this inspection. The well was fenced with a locked man door. The tank battery consisted of one 210 BBL tank, one 100 BBL tank and two mechanical separators. The fence door was broken and unlocked on the separator fence. The diked tank battery was shared with well 2-1188 and did not have a locked man door. The 100 BBL tank has not been removed from the tank battery and the load lines and tank valves have not been locked. The identification for this well needs to be updated to reflect current ownership information. The lease access was stable and gate at access locked.
1880713664 2016-02-09 UrbanProduction Wells Violations Noted I inspected this well as part of routine inspection activity. The well and battery are accessed at the end of Viceroy. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in a board-on-board enclosure. Fittings and connections at the wellhead were secure. The battery is comprised of one 210-barrel steel production tank, one 100-barrel steel brine tank and separator in separate board-on-board enclosures. Enclosure gates were locked and secure. Hatches were closed and sealed. Secondary containment was present and intact. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surround both the well and battery and did not observe any signs of impact relative to the production activity. Signage was present. I noted the following safety issues: The load-line valves were not locked. The owner must remedy the following by 04/04/2016: secure the load-line valves with locks. Contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
2145625832 2018-04-17 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: no locks at the load-line valves, and severe rusting/corrosion of the 210-barrel production tank. At the time of this inspection, I observed the following: the were no locks at the load-line valves and the 210-barrel tank remains in place, but was not being actively produced into. The ID signage remained from prior ownership and not accurate. I had previously contacted the company on several occasions since the issuance of the compliance notice regarding the deficiencies. The company had made pledges to remedy the deficiencies. The well was not in active production at the time of this inspection.
372550150 2018-2-13 0:00: UP No Violations 0.50
384170973 2006-11-15 0:00 PL No Violations
733548168 2015-4-22 0:00: UP No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0823819888 US-OH-129394 2017-12-28 Well insufficiently equipped to prevent escape of oil and gas
1430489439 US-OH-112579 2015-11-13 No SPCC dike/or failure to keep dike free of water or oil
1880713664 US-OH-118812 2016-04-27 LOCKS

For data sources see[9]

References