34-085-20919

Well Details

Well ID: 34-085-20919
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Perry Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: STROPKEY
License Status: Producing
License Date: 1987-08-12
Spud Date: 1987-09-29
Spud Drilling Contractor: SHERMAN DRLG
Final Drill Date: 1987-10-03
Well Total Depth: 3090.00 ft
Configuration: Vertical
Latitude: 41.740000
Longitude: -81.190000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1987-08-12 1249 CUTTER OIL CO GeoDate 8/12/87
Oil and Gas 1987-08-12 Issued Date Expired Date Acres 0000000 Tool Type RTAF Proposed Formation Proposed Depth 03090 Proposed Drill Depth 03090
Original Spud 1987-09-29
Completed 1987-10-03
Reached Total Depth 1987-10-03
Completion Report Received 1987-10-23
Change of Owner 2003-07-21 Operator changed from 1249, CUTTER OIL CO to 7033, BROAD STREET ENERGY COMPANY
Change of Owner 2015-07-16 Operator changed from 8685, M & R INVESTMENTS OHIO LLC BROAD STREET ENERGY COMPANY to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2016-07-14

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2912 2964 2
2912 2964 2
2912 2964 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 225 Mscf 0
H2O 0 1675 Bbl 60000
ACID 0 500 Gal 0 N2 ASSIST. BD 1100 PSI, 1000 PSI.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 CUTTER OIL COMPANY 0.00 0.00 0
1988 CUTTER OIL COMPANY 10955.00 126.00 285
1989 CUTTER OIL COMPANY 28908.00 514.00 365
1990 CUTTER OIL COMPANY 24652.00 175.00 365
1991 CUTTER OIL COMPANY 20387.00 127.00 365
1992 CUTTER OIL COMPANY 13531.00 0.00 365
1993 CUTTER OIL COMPANY 7842.00 92.00 365
1994 CUTTER OIL COMPANY 6997.00 0.00 365
1995 CUTTER OIL COMPANY 4961.00 0.00 365
1996 CUTTER OIL COMPANY 3607.00 0.00 365
1997 CUTTER OIL COMPANY 2884.00 0.00 365
1998 CUTTER OIL COMPANY 4145.00 0.00 365
1999 CUTTER OIL COMPANY 2505.00 0.00 365
2000 CUTTER OIL COMPANY 2238.00 0.00 365
2001 CUTTER OIL COMPANY 605.00 0.00 365
2002 CUTTER OIL COMPANY 732.00 0.00 365
2003 BROAD STREET ENERGY COMPANY 944.00 0.00 365
2004 BROAD STREET ENERGY COMPANY 10830.00 162.00 365
2005 BROAD STREET ENERGY COMPANY 5896.00 0.00 365
2006 BROAD STREET ENERGY COMPANY 3627.00 120.00 365
2007 BROAD STREET ENERGY COMPANY 3605.00 0.00 365
2008 BROAD STREET ENERGY COMPANY 2046.00 0.00 365
2009 BROAD STREET ENERGY COMPANY 4946.00 0.00 365
2010 BROAD STREET ENERGY COMPANY 3111.00 133.00 365
2011 BROAD STREET ENERGY COMPANY 2971.00 0.00 365
2012 BROAD STREET ENERGY COMPANY 2401.00 55.00 366
2013 BROAD STREET ENERGY COMPANY 2132.00 0.00 365
2014 BROAD STREET ENERGY COMPANY 2050.00 0.00 365
2015 M & R INVESTMENTS OHIO LLC 1130.00 0.00 365
2016 M & R INVESTMENTS OHIO LLC 2476.00 96.00 365
2017 M & R INVESTMENTS OHIO LLC 1045.00 0.00 365
2018 M & R INVESTMENTS OHIO LLC 1680.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 CUTTER OIL COMPANY Brine 1440 0
1988 CUTTER OIL COMPANY Brine 1420 285
1989 CUTTER OIL COMPANY Brine 385 365
1990 CUTTER OIL COMPANY Brine 330 365
1991 CUTTER OIL COMPANY Brine 365 365
1992 CUTTER OIL COMPANY Brine 315 365
1993 CUTTER OIL COMPANY Brine 0 365
1994 CUTTER OIL COMPANY Brine 0 365
1995 CUTTER OIL COMPANY Brine 0 365
1996 CUTTER OIL COMPANY Brine 0 365
1997 CUTTER OIL COMPANY Brine 0 365
1998 CUTTER OIL COMPANY Brine 150 365
1999 CUTTER OIL COMPANY Brine 70 365
2000 CUTTER OIL COMPANY Brine 0 365
2001 CUTTER OIL COMPANY Brine 0 365
2002 CUTTER OIL COMPANY Brine 0 365
2003 CUTTER OIL COMPANY Brine 43 243
2004 BROAD STREET ENERGY COMPANY Brine 401 365
2005 BROAD STREET ENERGY COMPANY Brine 170 365
2006 BROAD STREET ENERGY COMPANY Brine 157 365
2007 BROAD STREET ENERGY COMPANY Brine 33 365
2008 BROAD STREET ENERGY COMPANY Brine 158 365
2009 BROAD STREET ENERGY COMPANY Brine 126 365
2010 BROAD STREET ENERGY COMPANY Brine 0 365
2011 BROAD STREET ENERGY COMPANY Brine 32 365
2012 BROAD STREET ENERGY COMPANY Brine 41 366
2013 BROAD STREET ENERGY COMPANY Brine 82 365
2014 BROAD STREET ENERGY COMPANY Brine 82 365
2015 M & R INVESTMENTS OHIO LLC Brine 0 365
2016 M & R INVESTMENTS OHIO LLC Brine 63 365
2017 M & R INVESTMENTS OHIO LLC Brine 0 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1326753238 2010-11-23 0:00 PW No Violations
-1655021965 2020-1-28 0:00: UP No Violations 0.80
-713830335 2017-2-6 0:00:0 UP No Violations 1.00
000PL14187 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0713830335 2017-02-06 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system and associated tank battery located within a commercial nursery facility. The battery was comprised of a 210-barrel steel production tank and 1000-gallon poly brine tank. Connections and fittings at the battery and wellhead were secure and free from signs of leakage or problems. The secondary containment was intact. The access road is shared with the facility and was in good condition. I walked the areas surrounding the wellhead and battery and found no signs of erosional deficits or impact.
1326753238 2010-11-23 Production Wells No Violations There were no violations found.
1408129896 2014-08-15 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 10/03/1987. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate chain-link enclosures. The wellhead and surrounding area are free of signs of leaks or other impacts. The wellhead and battery are located in within the confines of an active commercial nursery facility (Stropkey). Access to the wellhead and battery are via shared, gravel and dirt roads within the nursery facility. The battery is comprised of 1 steel 210-barrel production tank, 1 25-barrel poly brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery. I did not observe any signs or evidence of leakage, spills, or problems. There is no identification at the wellhead or battery. I notified Broad Street that a compliant ID must be placed at the well within 30 days.
PL14187 PL No Violations

For data sources see[9]