34-085-20535

Well Details

Well ID: 34-085-20535
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Madison Township
Operator Name: MILLER LARS
Well Pad ID:
Farm/Lease Name: DRZAZGA
License Status: Domestic Well
License Date: 1991-07-16
Spud Date: 1984-01-31
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1984-02-02
Well Total Depth: 2985.00 ft
Configuration: Vertical
Latitude: 41.800000
Longitude: -81.100000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-01-10 164 PETRO EVALUATION SERV INC GeoDate 1/10/84
Oil and Gas 1984-01-10 Issued Date 12/30/83 Expired Date 6/27/84 Acres 0021383 Tool Type RTA Proposed Formation CLINTON Proposed Depth 02985 Proposed Drill Depth 02985
Original Spud 1984-01-31
Completed 1984-02-02
Reached Total Depth 1984-02-02
Completion Report Received 1984-05-10
CO 1991-07-16 164 PETRO EVALUATION SERV INC GeoDate 7/16/91
Unknown 1991-07-16 Issued Date 7/16/91 Expired Date 7/15/92 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Construction Permit Expires 1992-07-15
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 2781 2890 0
2781 2890 0
2006-09-11 2801 2889 15
2801 2889 15
2781 2890 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 40000 FRAC;H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 PETRO EVALUATION SERVICES INC 2623.00 0.00 365
1985 SHONGUM OIL & GAS INC 5087.00 0.00 360
1986 PETRO EVALUATION SERVICES INC 2879.00 0.00 365
1987 PETRO EVALUATION SERVICES INC 2182.00 0.00 365
1988 PETRO EVALUATION SERVICES INC 2110.00 75.00 365
1989 PETRO EVALUATION SERVICES INC 1796.00 0.00 365
1990 PETRO EVALUATION SERVICES INC 2277.00 0.00 365
1991 PETRO EVALUATION SERVICES INC 1035.00 43.00 212

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 PETRO EVALUATION SERVICES INC Brine 0 365
1985 SHONGUM OIL & GAS INC Brine 410 360
1986 PETRO EVALUATION SERVICES INC Brine 165 365
1987 PETRO EVALUATION SERVICES INC Brine 300 365
1988 PETRO EVALUATION SERVICES INC Brine 270 365
1989 PETRO EVALUATION SERVICES INC Brine 340 365
1990 PETRO EVALUATION SERVICES INC Brine 175 365
1991 PETRO EVALUATION SERVICES INC Brine 185 212

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
000PL14344 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0582634966 2019-01-22 Exempt Well Pre Transfer No Violations I conducted an exempt domestic pre-transfer inspection on this well. At the time of this inspection, the well consisted of a 4.5 inch casing swaged into a 2 inch line with open valve. The 2 inch line was further reduced into a 1 inch line with an open valve and regulator. The well was located approximately 435 feet from the nearest unoccupied dwelling and approximately 473 feet from the nearest occupied dwelling. I contacted landowner Edward Dake to confirm the well is currently being used for domestic purposes. Mr. Dake stated the well was being used domestically at his home. The parcel the well is located on does belong to the Dakes. I also discussed with Mr. Dake that identification would need to be installed at the well location. No other issues were observed.
1537893619 2018-09-25 Exempt Well Pre Transfer No Violations I inspected this well as part of evaluation for transfer of ownership from Petro Evaluation Service, Inc. to the existing surface land owner. At the time of this inspection, I noted the following: a wellhead with reducer swage from 4.5-inch to 2-inch and to subsequent 1-inch domestic flowline connections, including pressure regulators and associated appurtenances. The connections were secure. There were no other active connecitons. There was no active sales line connection. There was no other production elements (e.g. tank battery, separator system). I contacted the landowner and, as of this report filing, had not received a response.
1684807638 2017-01-25 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection I observed the following: a wellhead with 4.5-inch to 2-inch reducer and flow-line fittings for domestic connection. There were no other production appurtenances. The well has not shown reported production since 1991. I contacted Steve Franks with Petro Evaluation Serv. Inc. Steve indicated that ownership of the well had been transferred to a previous property owner at some point in the past but that the records of the transfer had been discarded, and no apparent filing of the transfer had been made to ODNR. I contacted Kathryn Smith with ODNR Central Office. She reported that no transfer paperwork was identified. Based on these findings, I advised Steve Franks that ODNR would be sending the necessary transfer of ownership paperwork.
2044493203 2018-01-31 UrbanProduction Wells No Violations I inspected this well location as a follow-up to previous inspections and discussions with the owner/operator regarding the status of this well. The well has been utilized by the landowner for house gas, but otherwise not produced commercially. Steve Franks, with Petroleum Evaluation Services Inc., has reported previously that there had been problems with on-going attempts to secure transfer of the well to the landowner. At the time of this inspection, I contacted Steve Franks again. He reported that no additional progress had been made in transferring the well. I advised Steve that I was issuing an order to plug the well. The well owner/operator shall submit a written plugging schedule to Inspector Stephen Tompkins at ODNR Uniontown Field Office, 3575 Forest Lake Drive, Suite 150 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
582634966 2019-1-22 0:00: EX No Violations
PL14344 PL No Violations

For data sources see[9]