If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-20502 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.73,"lon":-81.16,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Perry Township | |
Operator Name: DIVERSIFIED PRODUCTION LLC | |
Well Pad ID: | |
Farm/Lease Name: ADAMS H | |
License Status: Producing | |
License Date: 1984-03-15 | |
Spud Date: 1984-06-12 | |
Spud Drilling Contractor: B & K DRLG | |
Final Drill Date: 1984-06-16 | |
Well Total Depth: 3187.00 ft | |
Configuration: Vertical | |
Latitude: 41.730000 | |
Longitude: -81.160000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1983-11-10 | Issued Date 11/10/83 Expired Date 5/8/84 Acres 0029460 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1984-03-15 | 198 VIKING RESOURCES CORP GeoDate 3/15/84 |
Oil and Gas | 1984-03-15 | Issued Date 3/15/84 Expired Date 9/11/84 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03187 Proposed Drill Depth 03187 |
Original Spud | 1984-06-12 | R.L. 3-17-84 |
Completed | 1984-06-16 | R.L. 3-17-84 |
Reached Total Depth | 1984-06-16 | R.L. 3-17-84 |
Completion Report Received | 1984-07-12 | R.L. 3-17-84 |
CO | 1984-09-04 | 198 VIKING RESOURCES CORP GeoDate 11/10/83 |
Construction Permit Expires | 1984-09-11 | R.L. 3-17-84 |
Change of Owner | 2001-02-16 | Operator changed from 198, VIKING RESOURCES CORP to 1966, PETROX INC |
Change of Owner | 2002-01-18 | Operator changed from 1966, PETROX INC to 7033, BROAD STREET ENERGY COMPANY |
Change of Owner | 2015-07-16 | Operator changed from 8685, M & R INVESTMENTS OHIO LLC BROAD STREET ENERGY COMPANY to 8685, M & R INVESTMENTS OHIO LLC |
Record Last Modified | 2017-02-15 | R.L. 3-17-84 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 2962 | 3086 | 0 |
2962 | 3086 | 0 | |
2006-09-11 | 2991 | 3041 | 12 |
2991 | 3041 | 12 | |
2962 | 3086 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
FOAM | 0 | 0 | 50000 | FRAC;FOAM,SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | VIKING RESOURCES LLC | 5644.00 | 0.00 | 0 |
1985 | VIKING RESOURCES LLC | 43152.00 | 0.00 | 363 |
1986 | VIKING RESOURCES LLC | 30412.00 | 0.00 | 353 |
1987 | VIKING RESOURCES LLC | 27410.00 | 0.00 | 365 |
1988 | VIKING RESOURCES LLC | 20705.00 | 94.00 | 365 |
1989 | VIKING RESOURCES LLC | 15806.00 | 0.00 | 334 |
1990 | VIKING RESOURCES LLC | 13653.00 | 0.00 | 362 |
1991 | VIKING RESOURCES LLC | 4115.00 | 0.00 | 236 |
1992 | VIKING RESOURCES LLC | 2836.00 | 0.00 | 297 |
1993 | VIKING RESOURCES LLC | 6190.00 | 0.00 | 365 |
1994 | VIKING RESOURCES LLC | 4223.00 | 0.00 | 365 |
1995 | VIKING RESOURCES LLC | 1876.00 | 0.00 | 0 |
1996 | VIKING RESOURCES LLC | 1758.00 | 0.00 | 0 |
1997 | VIKING RESOURCES LLC | 1239.00 | 0.00 | 0 |
1998 | VIKING RESOURCES LLC | 1897.00 | 0.00 | 365 |
2000 | RESOURCE AMERICA INC | 99.00 | 0.00 | 365 |
2001 | VIKING RESOURCES LLC | 0.00 | 0.00 | 365 |
2002 | BROAD STREET ENERGY COMPANY | 4066.00 | 76.00 | 336 |
2003 | BROAD STREET ENERGY COMPANY | 1983.00 | 0.00 | 365 |
2004 | BROAD STREET ENERGY COMPANY | 5362.00 | 0.00 | 365 |
2005 | BROAD STREET ENERGY COMPANY | 5925.00 | 0.00 | 365 |
2006 | BROAD STREET ENERGY COMPANY | 6024.00 | 0.00 | 365 |
2007 | BROAD STREET ENERGY COMPANY | 5087.00 | 0.00 | 365 |
2008 | BROAD STREET ENERGY COMPANY | 4018.00 | 0.00 | 365 |
2009 | BROAD STREET ENERGY COMPANY | 4120.00 | 0.00 | 365 |
2010 | BROAD STREET ENERGY COMPANY | 3876.00 | 0.00 | 365 |
2011 | BROAD STREET ENERGY COMPANY | 3079.00 | 0.00 | 365 |
2012 | BROAD STREET ENERGY COMPANY | 2309.00 | 0.00 | 366 |
2013 | BROAD STREET ENERGY COMPANY | 2092.00 | 0.00 | 365 |
2014 | BROAD STREET ENERGY COMPANY | 2104.00 | 0.00 | 365 |
2015 | M & R INVESTMENTS OHIO LLC | 1454.00 | 0.00 | 365 |
2016 | M & R INVESTMENTS OHIO LLC | 2178.00 | 0.00 | 365 |
2017 | M & R INVESTMENTS OHIO LLC | 1449.00 | 0.00 | 365 |
2018 | M & R INVESTMENTS OHIO LLC | 762.00 | 0.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1584650776 | 2003-8-4 0:00:0 | PW | No Violations | |
-1925079411 | 2012-8-3 0:00:0 | UP | No Violations | |
-606268005 | 2019-11-14 0:00 | UP | No Violations | |
000PL14361 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0049543378 | 2017-06-14 | Production Wells | Violations Noted | I inspected this production well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery located within a commercial nursery facility. Fittings and connections at the wellhead and battery were secure. There was a significant overgrowth of vegetation in the wellhead enclosure making a detailed inspection not possible. The load-line was plugged. There was secondary containment which was intact and dry. I walked the areas around the wellhead and battery and found no signs of impacts or problems. The owner must clear the vegetation from the well interior so that inspection can be facilitated. This must be corrected on or before 07/21/17. Please contact Inspector Stephen Tompkins at 330-907-4647 with any questions regarding this Compliance Notice. |
1346758026 | 2012-08-03 | UrbanProduction Wells | No Violations | The unit is comprised of a one-tank battery (1 210-barrel production) and a wellhead with mechanical lift. The well is currently in production. The wellhead is remotely located within the nursery area. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. The tank battery dike is overgrown with weeds and requires maintenance. I did not observe any leaks, spills, or other signs of contamination. The gates at the tank battery and wellhead need locks . I called Matt Sisson regarding the locks and maintenance. He indicated that the items would be addressed within the next week. |
1395850140 | 2014-03-26 | UrbanProduction Wells | No Violations | The unit is comprised of a mechanical plunger lift unit in a chain-link enclosure and an aboveground storage tank (ASTP) battery in a separate chain-link enclosure. The battery is comprised of 1 210-barrel production tank, and separator. The battery secondary containment is good. The load-outs are bull-plugged. No problems noted. |
1449111072 | 2017-07-24 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued Compliance Notice. At the time of the prior inspection I had noted that the wellhead enclosure had become overgrown with vegetation making adequate inspection of the wellhead not possible. At the time of this inspection, I observed that the vegetation had been cut back sufficiently to permit inspection of the wellhead. I noted that the fittings and connections at the wellhead were secure and free from leakage. I walked the areas around the wellhead and battery and found no signs of problems. |
1478536029 | 2016-11-07 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located on the grounds of a commercial nursery facility, and the areas immediately surrounding the production equipment consisted of agricultural fields and plots utilized for cultivation of trees and shrubbery. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate chain-link enclosures. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. The 210-barrel tank lid was closed and secure. There was secondary containment which was intact and free from signs of leakage or spills. I walked the areas surrounding the wellhead and battery and did not observe an y signs of impact or surficial degradation relatable to the well operations. I observed the following maintenance deficiency: the ID signage had become faded and unreadable. I notified John Raber (M&R Investments) about the need for sign maintenance. |
1584650776 | 2003-08-04 | Production Wells | No Violations | TB 210BBl @septic ,seperator |
1785062185 | 2011-04-06 | Production Wells | No Violations | No violations at this time. |
1925079411 | 2012-08-03 | UrbanProduction Wells | No Violations | I observed the unit to consist of a tank battery (TB) located approximately 75 feet from the main road. The TB is comprised of one 210 barrel (BBL) |
49543378 | 2017-6-14 0:00: | PW | No Violations | 0.50 |
PL14361 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0049543378 | US-OH-125419 | 2017-08-22 | General Safety |
For data sources see[9]