Well Details

Well ID: 34-085-20498
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Perry Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: OTTO # 1
License Status: Producing
License Date: 1984-05-24
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth: 0.00 ft
Configuration: Vertical
Latitude: 41.740000
Longitude: -81.180000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-11-03 198 VIKING RESOURCES CORP GeoDate 11/3/83
Oil and Gas 1983-11-03 Issued Date 11/3/83 Expired Date 5/1/84 Acres 0032761 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1984-05-24 198 VIKING RESOURCES CORP GeoDate 5/24/84
Oil and Gas 1984-05-24 Issued Date 5/24/84 Expired Date 11/20/84 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Construction Permit Expires 1984-11-20 RBDMS Rec
Change of Owner 2003-07-21 Operator changed from 198, VIKING RESOURCES CORP to 1249, CUTTER OIL CO
Change of Owner 2015-07-16 Operator changed from 8685, M & R INVESTMENTS OHIO LLC BROAD STREET ENERGY COMPANY to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 CUTTER OIL COMPANY 52481.00 50.00 262
1988 CUTTER OIL COMPANY 32896.00 0.00 365
1989 CUTTER OIL COMPANY 21539.00 0.00 365
1990 CUTTER OIL COMPANY 10977.00 64.00 365
1991 CUTTER OIL COMPANY 13262.00 0.00 365
1992 CUTTER OIL COMPANY 8400.00 0.00 365
1993 CUTTER OIL COMPANY 3164.00 0.00 365
1994 CUTTER OIL COMPANY 1981.00 0.00 365
1995 CUTTER OIL COMPANY 26.00 0.00 365
1996 CUTTER OIL COMPANY 66.00 0.00 365
1997 CUTTER OIL COMPANY 68.00 0.00 365
1998 CUTTER OIL COMPANY 0.00 0.00 0
1999 CUTTER OIL COMPANY 0.00 0.00 0
2000 RESOURCE AMERICA INC 305.00 0.00 365
2001 CUTTER OIL COMPANY 0.00 0.00 0
2002 CUTTER OIL COMPANY 0.00 0.00 0
2003 CUTTER OIL COMPANY 0.00 0.00 0
2004 BROAD STREET ENERGY COMPANY 1154.00 0.00 365
2005 BROAD STREET ENERGY COMPANY 4420.00 0.00 365
2006 BROAD STREET ENERGY COMPANY 3680.00 43.00 365
2007 BROAD STREET ENERGY COMPANY 2402.00 0.00 365
2008 BROAD STREET ENERGY COMPANY 2366.00 0.00 365
2009 BROAD STREET ENERGY COMPANY 2365.00 0.00 365
2010 BROAD STREET ENERGY COMPANY 2734.00 0.00 365
2011 BROAD STREET ENERGY COMPANY 2230.00 0.00 365
2012 BROAD STREET ENERGY COMPANY 1904.00 0.00 366
2013 BROAD STREET ENERGY COMPANY 1737.00 0.00 365
2014 BROAD STREET ENERGY COMPANY 905.00 0.00 365
2015 M & R INVESTMENTS OHIO LLC 241.00 0.00 365
2016 M & R INVESTMENTS OHIO LLC 603.00 21.00 365
2017 M & R INVESTMENTS OHIO LLC 223.00 0.00 365
2018 M & R INVESTMENTS OHIO LLC 0.00 0.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 CUTTER OIL COMPANY Brine 3595 262
1988 CUTTER OIL COMPANY Brine 255 365
1989 CUTTER OIL COMPANY Brine 200 365
1990 CUTTER OIL COMPANY Brine 130 365
1991 CUTTER OIL COMPANY Brine 245 365
1992 CUTTER OIL COMPANY Brine 150 365
1993 CUTTER OIL COMPANY Brine 0 365
1994 CUTTER OIL COMPANY Brine 80 365
1995 CUTTER OIL COMPANY Brine 0 365
1996 CUTTER OIL COMPANY Brine 0 365
1997 CUTTER OIL COMPANY Brine 0 365
1998 CUTTER OIL COMPANY Brine 0 0
1999 CUTTER OIL COMPANY Brine 0 0
2000 RESOURCE AMERICA INC Brine 0 365
2001 CUTTER OIL COMPANY Brine 0 0
2002 CUTTER OIL COMPANY Brine 0 0
2003 CUTTER OIL COMPANY Brine 0 0
2004 BROAD STREET ENERGY COMPANY Brine 0 365
2005 BROAD STREET ENERGY COMPANY Brine 325 365
2006 BROAD STREET ENERGY COMPANY Brine 57 365
2007 BROAD STREET ENERGY COMPANY Brine 106 365
2008 BROAD STREET ENERGY COMPANY Brine 86 365
2009 BROAD STREET ENERGY COMPANY Brine 42 365
2010 BROAD STREET ENERGY COMPANY Brine 224 365
2011 BROAD STREET ENERGY COMPANY Brine 0 365
2012 BROAD STREET ENERGY COMPANY Brine 70 366
2013 BROAD STREET ENERGY COMPANY Brine 80 365
2014 BROAD STREET ENERGY COMPANY Brine 0 365
2015 M & R INVESTMENTS OHIO LLC Brine 0 365
2016 M & R INVESTMENTS OHIO LLC Brine 80 365
2017 M & R INVESTMENTS OHIO LLC Brine 0 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1570879987 2017-9-19 0:00: UP No Violations 1.00
-161701308 2015-10-9 0:00: UP No Violations
-191870454 2016-3-31 0:00: UP No Violations 1.00
000PL14362 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0161701308 2015-10-09 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection. Enclosures have been locked. The ID signage has been updated. The compliance issues have been resolved.
0188177773 2010-11-23 Production Wells No Violations There were no violations.
0191870454 2016-03-31 UrbanProduction Wells Violations Noted I inspected this producing well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with mechanical plunger lift system in a small chain-link enclosure. The associated battery is located remotely, on Maine Rd. near the #2-0575 well (Otto #2) and was comprised of one 210-barrel steel production tank, 50-barrel poly brine tank and separator in a chain-link enclosure which was partially missing some sections. Load-lines were not locked. Signage was present. Secondary containment was intact. I walked the area around the well and battery and did not observe any signs of leakage or other impacts associated with the on-going production activity. The owner must lock and secure the load lines by 04/30/2016. Please contact Inspector Stephen Tompkins at 330-907-4647 with questions regarding this inspection.
0240903642 2015-09-10 UrbanProduction Wells Violations Noted I inspected this producing unit as part of routine inspection and status check. The wellhead is located in a small chain-link enclosure. Fittings and connections at the wellhead are secure and free from leakage. There is no identification at the wellhead. The tank battery is located 3/4 mile east of the wellhead. The load lines are not locked . The identification at the tank battery is not current and the emergency contact number is non-functioning. The owner must place signage at the wellhead and battery which is compliant with 1501:9-9-05(E)(1) , and secure the load lines with locks. These actions must be completed by 10/12/2015. Please contact Inspector Stephen Tompkins at 330-907-4647 regarding this inspection.
0399838920 2014-05-05 UrbanProduction Wells No Violations The previously identified missing ID placard at the wellhead is still missing. The ID placard at the tank battery is not readable. The production tank is in poor condition and weeping. A tree has fallen onto the tank. The fence is broken down. These conditions were extant at the last inspection. Ed Butler at Broad Street Energy was notified via email at that time. No repairs have been made. Im notifying Broad Street a second time about the lack of ID placard compliance and maintenance issues.
1137808447 2019-8-6 0:00:0 UP No Violations
1570879987 2017-09-19 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: No locks at the load-lines and ID signage was missing. At the time of this inspection, the noted deficiencies had been mitigated. I walked the areas surrounding the well and battery and found no signs of problems or impacts.
1667179030 2013-10-04 UrbanProduction Wells No Violations The producing unit consists of a mechanical plunger lift unit at the wellhead and an aboveground storage tank (AST) battery. The battery is comprised of 1 240-barrel steel production tank, 1 50-barrel poly brine tank, and separator unit. The wellhead is enclosed in a chain-link enclosure. The tank battery is partially enclosed in a chain-link fence. Portions of the fence are missing and broken down. Large tree limbs have fallen into the battery. The side of the production tank is severely rusted and weeping oil. There is adequate secondary containment. There is no ID at the wellhead. The battery ID placard is in poor condition. The load outs are not locked but are bull-plugged. I will notify Broad Street Energy about the maintenance issues.
188177773 2010-11-23 0:00 PW No Violations
240903642 2015-9-10 0:00: UP No Violations 1.00
399838920 2014-5-5 0:00:0 UP No Violations
PL14362 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0191870454 US-OH-119282 2017-10-23 9-05E3 LOCKS
0240903642 US-OH-122416 2016-04-27 ID (a-i)
0240903642 US-OH-122417 2016-04-27 LOCKS

For data sources see[7]