34-085-20372

Well Details

Well ID: 34-085-20372
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: SCHULTZ
License Status: Plugged and Abandoned
License Date: 2018-04-25
Spud Date: 1982-07-08
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1982-07-14
Well Total Depth: 3195.00 ft
Configuration: Vertical
Latitude: 41.690000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1982-06-16 957 OSAIR INC GeoDate 6/16/82
Oil and Gas 1982-06-16 Issued Date 6/16/82 Expired Date 12/15/82 Acres 0025000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1982-07-08 PERMIT EXPIRED. UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT
Completed 1982-07-14 PERMIT EXPIRED. UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT
Reached Total Depth 1982-07-14 PERMIT EXPIRED. UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT
Completion Report Received 1982-07-23 PERMIT EXPIRED. UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT
APP 2006-03-13 Proposed Formations:CLINTON, Issued Date:3/13/2006, Expired Date:3/13/2007 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2006-03-27 Operator changed from 957, OSAIR INC to 7447, GREAT PLAINS EXPLORATION LLC
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
APP 2018-04-25 Proposed Formations:CLINTON, Issued Date:4/25/2018, Expired Date:4/24/2020 12:00:00 PM, Drilling unit acres:25, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-04-26 PERMIT EXPIRED. UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT
Record Last Modified 2018-07-11 PERMIT EXPIRED. UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT
Construction Permit Expires 2020-04-24 PERMIT EXPIRED. UPDATE LOCATION PER DOGRM SURVEY 5/21/18 ALE. GMM UPDATED PLUG STATUS PER PLUG REPORT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-05-15 3013 3045 20
3013 3045 20
3013 3045 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 40000 150M SCF NITROGEN ASSIST

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 OSAIR INC 7059.00 80.00 365
1989 OSAIR INC 3564.00 74.00 365
1990 OSAIR INC 977.00 0.00 365
2005 GREAT PLAINS EXPLORATION LLC 0.00 0.00 365
2006 GREAT PLAINS EXPLORATION LLC 5508.00 160.00 365
2007 GREAT PLAINS EXPLORATION LLC 1501.00 169.00 365
2008 GREAT PLAINS EXPLORATION LLC 4150.00 240.00 365
2009 GREAT PLAINS EXPLORATION LLC 2183.00 302.00 365
2010 GREAT PLAINS EXPLORATION LLC 2168.00 185.00 365
2011 GREAT PLAINS EXPLORATION LLC 2904.00 82.00 365
2012 GREAT PLAINS EXPLORATION LLC 3020.00 55.00 366
2013 GREAT PLAINS EXPLORATION LLC 2532.00 84.00 365
2014 GREAT PLAINS EXPLORATION LLC 2359.00 26.00 365
2015 GREAT PLAINS EXPLORATION LLC 1128.00 26.00 365
2016 ROCKEFELLER OIL COMPANY LLC 736.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 OSAIR INC Brine 120 365
1989 OSAIR INC Brine 231 365
1990 OSAIR INC Brine 0 365
2005 GREAT PLAINS EXPLORATION LLC Brine 0 365
2006 GREAT PLAINS EXPLORATION LLC Brine 0 365
2007 GREAT PLAINS EXPLORATION LLC Brine 765 365
2008 GREAT PLAINS EXPLORATION LLC Brine 280 365
2009 GREAT PLAINS EXPLORATION LLC Brine 400 365
2010 GREAT PLAINS EXPLORATION LLC Brine 520 365
2011 GREAT PLAINS EXPLORATION LLC Brine 240 365
2012 GREAT PLAINS EXPLORATION LLC Brine 80 366
2013 GREAT PLAINS EXPLORATION LLC Brine 140 365
2014 GREAT PLAINS EXPLORATION LLC Brine 45 365
2015 GREAT PLAINS EXPLORATION LLC Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1168487866 2018-4-25 0:00: PB No Violations 8.00
-1223510575 2016-2-16 0:00: UP No Violations 0.50
-128805378 2012-10-26 0:00 UP No Violations
-1585021675 2018-4-27 0:00: PB No Violations 2.00
-1593667100 2018-5-9 0:00:0 FR No Violations 2.00
-1810238897 2018-4-26 0:00: PB No Violations 4.00
-326492319 2009-12-16 0:00 PW No Violations
000PL14416 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0098977634 2017-09-06 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The wellhead pump jack system and associated tank battery are located on an undeveloped parcel in an otherwise suburban, residential development. At the time of this inspection, the load lines and enclosure gates were locked and secure. Fittings and connections at the wellhead and battery were secure and free from signs of leaks, spills, or other problems. I noted that the ID signage had not been updated to reflect the change of ownership that occurred in 2016. I have previously spoken with John Magnussen about the signage change over, to which the response has been that issues such as this will be handled as the owner is able.
0114929072 2018-04-13 UrbanProduction Wells No Violations I inspected this well location pursuant to Complaint #5817. A report of gas odor had been made to the Mentor Fire Department. Upon my inspection, I found John Magnussen from Rockefeller oil on location making the well ready for anticipated plugging and abandonment. The well was shut-in and the pump jack assembly had been removed from the well. I did not encounter any leaking gas or odors. I contacted the Mentor Fire Department and reported my findings.
0128805378 2012-10-26 UrbanProduction Wells No Violations The unit consists of a 2-tank battery with mechanical separator in a 8-foot wooden fence. The spacing is in accordance with the rule, and the valves and mechanicals are in good repair. The dike is adequate; however, the dike drain is an open-ended pipe. I did not observe any signs of leaking product or gas vapors. The wellhead is fitted with a pumpjack and is enclosed in a 6-foot wooden fence. The only ID on the unit is located on the inside of the fence and is not visible. I called Tim Reilly of Great Plains and advised him about the need for ID and dike drain modification. I indicated that the requested date for completion is 12/31/2012.
0326492319 2009-12-16 Production Wells No Violations A fix on the tank battery location was obtained. There were no violations.
0504741266 2018-03-19 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection I found the following: The well was in active production with pump jack system and associated tank battery, located in separate board-on-board enclosures which were locked. Fittings and connections were secure and free from signs of leakage or problems.
0695039830 2018-04-24 Plug / Plug Back No Violations I was on location to witness plugging and abandonment being performed by Nicks Well Plugging under contract to the well owner. During my inspection, I noted the following activities were performed: crews from the plugging contractor removed the existing tubing and pump rods. The rods had become stuck in the tubing requiring the crews to simultaneously remove the rods and tubing together, and manually cut the rods at each joint. The well was previously loaded with fresh water and was static. Upon completion of rod removal, crews ran in with 91 joints of nominal 34 sections of 2.375-inch tubing. Plugging was to commence the following morning.
1067524818 2003-10-29 Production Wells No Violations inspected site found well Mr Magnusson was hooking up domestic service to house. EOG had pulled the meter station Years ago so there was no way to produce the wells in the area until know with the new drilling. Production line are being run for new wells
114929072 2018-4-13 0:00: UP No Violations 2.00
1168487866 2018-04-25 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activities being executed by Nicks Well Plugging. During my inspection, the following activities were performed: On 4/25/2018 , The 4.5-inch casing was mechanically ripped at 1,844 feet. Seven joints of nominal 43.3 casing were removed and circulation established. A Marcellus/Big Lime/Oriskany formation plug was set through 4.5-inch casing from 1540 to 1240 feet. Twenty-six joints of 4.5-inch casing were then removed, circulation established, and a combined bottom surface/top surface plug was set from 414 to surface. During placement of the surface plug, it was noted that there was some loss of fluid, and additional Class A cement was added, with loss-circulation material. At the completion, the top surface plug was allowed to stabilize for 30 minutes. The plug was noted to drop approximately 65 feet. The plug was allowed to stabilize overnight, until 04/26/18. During site activities, I monitored for the presence of combustible gas, including methane and hydrogen sulfide, and observed no detected readings.
1223510575 2016-02-16 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. At the time of my inspection, I observed the following elements: a wellhead with gasoline-fired pump jack system in a board-on-board enclosure which is locked. The enclosure is located in an otherwise open area in a primarily residential development. The tank battery was comprised of two 100-barrel low-profile tanks and mechanical separator in a separate board-on-board enclosure. Fittings and connections at the battery were secure. Tank lids were closed and secure. The battery enclosure gate was locked.
1510985574 2018-06-01 Final Restoration No Violations I inspected this well as an evaluation for final restoration. At the time of this inspection, the former well location had been re-graded. The production equipment had been removed. The flow-line/sales line stubs remained to be removed. I contacted John Magnussen with Rockefeller Oil about removal of the flow-line and removal of the stub connections. He indicated that these items would be removed within the next two weeks.
1524659913 2018-04-25 Plug / Plug Back No Violations I was on location to witness plugging and abandonment being conducted by Nicks Well Plugging for the well owner. During my inspection the following activities were conducted: the well was plugged with a series of staged formation and surface plugs with Class A Cement. It was noted during placement of the top surface plug that there was loss of fluids. Additional Class A cement slurry with loss-of-circulation material was added. Following addition of the additional material, it was noted that the top plug had dropped approximately 65 feet. It was agreed to allow the plug to stabilize over night and re-evaluate in the morning.
1524752583 2018-04-26 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activity which had been commenced on 4/23/18. At the time of this inspection, completion of plugging was pending evaluation of the top surface plug. At the completion, of activities on 04/25/18, the top surface plug had dropped approximately 65 feet. The plug was left to stabilize over night. Upon evaluation, the plug had dropped to approximately 250 feet below grade. An additional Class A cement top surface plug was mixed and top-loaded to grade. After 4 fours, I re-inspected the well and found the plug to be stable with no sign of drop.
1525879345 2018-05-09 Final Restoration No Violations I inspected this well location as an evaluation for final restoration following plugging and abandonment that had recently been performed. At the time of this inspection, the wellhead had been cut to below grade and buried. The tank battery had been dismantled and the area had been re-graded. Final restoration will remain pending the completion of restroation, including removal of the flow-line.
1526324089 2018-04-24 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activity being executed by Nicks Well Plugging for Rockefeller Oil Co., LLC. During my inspection, crews were working to remove the pump rods and tubing from the well, as well stage equipment and materials needed for plugging, to commence on 04/25/18. I observed no problems or issues dung this inspection.
1585021675 2018-04-27 Plug / Plug Back No Violations I was on location to inspect the surface plug that had been set on 04/26/18. At the time of this inspection, the surface plug remained level with the top of the surface casing and was set solid with no signs of leakage or problems. Crews were activley engaged in beginning site restoraiton.
1593667100 2018-05-09 Final Restoration No Violations I was on location to inspect the former well location, following plugging and abandonment activity that had been completed on 4/26/18. At the time of this inspection, the area of the former well was undergoing re-grading. The elements of the former tank battery were being removed and final restoration will remain pending completion of this work.
1629899197 2014-07-29 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 07/14/1982. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and pump jack system and aboveground storage tank (AST) battery. The wellhead and battery are located at the end of Red Oak Drive, which forms a cul-de-sac. There are no signs of leakage or problems at the wellhead. The battery is comprised of a total of 2 steel 100-barrel steel low-boy ASTs (1 production and 1 brine tank), and horizontal separator. Spacing from well to battery, and spacing of elements within the battery meet regulations. The battery is located in a separate board-on-board enclosure which is gated and locked. The load-outs are bull-plugged. The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery and wellhead which are legible and in good condition.
1810238897 2018-04-26 Plug / Plug Back No Violations I was on location to witness plugging and abandonment activities being executed by Nicks Well Plugging. During my inspection, the following activities were performed: The surface plug had been observed to settle to approximately 60 feet below grade. Upon inspection on the morning of 4/26/18, the plug was observed to have dropped approximately 250 feet below grade. An additional Class A plug was mixed and top-loaded to grade, and allowed to stabilize. Following placement of the top surface plug, no evidence of gas leakage was observed.
504741266 2018-3-19 0:00: UP No Violations
695039830 2018-4-24 0:00: PB No Violations 4.00
98977634 2017-9-6 0:00:0 UP No Violations 0.50
PL14416 PL No Violations

For data sources see[9]

References