Well ID: 34-085-20318 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.76,"lon":-81.16,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Perry Township | |
Operator Name: PETRO EVALUATION SERVICES INC | |
Well Pad ID: | |
Farm/Lease Name: LANGSHAW E | |
License Status: Producing | |
License Date: 1981-05-08 | |
Spud Date: 1981-05-10 | |
Spud Drilling Contractor: | |
Final Drill Date: 1981-05-17 | |
Well Total Depth: 3142.00 ft | |
Configuration: Vertical | |
Latitude: 41.760000 | |
Longitude: -81.160000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-05-08 | 164 PETRO EVALUATION SERV INC GeoDate 5/8/81 |
Original Spud | 1981-05-10 | |
Completed | 1981-05-17 | |
Reached Total Depth | 1981-05-17 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2958 | 3052 | 31 |
2958 | 3052 | 31 | |
2958 | 3052 | 31 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1200 Bbl | 27000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1128796841 | 2019-10-29 0:00 | UP | No Violations | |
-1264985379 | 2015-1-28 0:00: | UP | No Violations | 0.50 |
-1866969966 | 2018-8-30 0:00: | UP | No Violations | |
-555894902 | 2011-4-5 0:00:0 | PW | No Violations | |
0555894902 | 2011-04-05 | Production Wells | No Violations | No violations were found at the time. |
0706017121 | 2013-10-02 | UrbanProduction Wells | No Violations | The producing unit consists of a concoil unit at the wellhead and an aboveground storage tank (AST) battery. The battery is comprised of 1 140-barrel steel production tank, a skid-mounted compressor unit, and a separator unit. The elements are not enclosed. There is adequate secondary containment. The unit sign is not readable. Also, there has not been production reported for this unit since 2010. I will contact Petro Eval. Service and notify them about the need for adequate signage and up to date production reports. No other problems noted. |
1264985379 | 2015-01-28 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The wellhead concoil system and tank battery are located within the nursery facility and accessed via shared-use gravel and dirt roads within the facility. At the time of my inspection, the nursery is idle for winter. Several inches of snow cover the ground. Valves and connections at the wellhead and battery are secure. The ID sign is worn and owner information is not readable, I contacted John Braun, well tender for Perto Eval. Serv. He indicated that new signs have been prepared for this unit, as well as others, and will be deployed shortly. |
1328810618 | 2012-02-09 | UrbanProduction Wells | No Violations | Well is equipped with a Con-coil system. The tank battery is equipped with two separators, one 140 barrel tank and one 75 barrel tank. The operator is using a compressor on site. This well was in production at the time of inspection and an identification sign was posted. |
1496938010 | 2017-06-08 | Production Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system (concoil-style) and associated tank battery located within the active nursery facility. The well is between active rows of tree plantings and the battery is at the south perimeter of the field. Fittings and connections at both the well and battery were secure. The secondary containment was intact. ID signage was present. I walked the areas around the well and battery and found no signs of impact to the surface areas. Production reports were current and there were no indications of deficiencies with bonding or insurance in a review of electronic file information conducted on this date. |
1545156007 | 2018-12-18 | UrbanProduction Wells | No Violations | I conducted an inspection on this well. During this inspection, the well was observed to be equipped with a Concoil plunger lift assembly and in production. The tank battery location was comprised of one 140 BBL tank, one 75 BBL tank and two mechanical separators. There was a compressor unit at the tank battery location. The diked tank battery had legible identification and the lease access was stable. |
1866969966 | 2018-08-30 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. At the time of this inspection, the fittings and connections were secure with no signs of leakage or problems. The well was in active production. There was an active chart record. The load-lines were secure and plugged. I walked the areas surrounding the well and battery and found no signs of problems. The gravel-paved access road was in good condition with access to both the battery and the wellhead beyond. |
2035853536 | 2010-07-21 | Production Wells | No Violations | No violations were found at the time. |
706017121 | 2013-10-2 0:00: | UP | No Violations |
For data sources see[9]