X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-20226

Well Details

Well ID: 34-085-20226
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: DAVID OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: RUSSELL-BURDSALL-WARD INC
License Status: Producing
License Date: 1977-04-06
Spud Date: 1977-04-08
Spud Drilling Contractor:
Final Drill Date: 1977-04-15
Well Total Depth: 3122.00 ft
Configuration: Vertical
Latitude: 41.680000
Longitude: -81.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1977-04-08 GL=633.3, DF=640.3, KB=641.3 NO REPT.
Completed 1977-04-15 GL=633.3, DF=640.3, KB=641.3 NO REPT.
Reached Total Depth 1977-04-15 GL=633.3, DF=640.3, KB=641.3 NO REPT.
Change of Owner 2009-07-06 Operator changed from 5680, TYPRO LTD to 7909, JOHN D OIL & GAS COMPANY
Change of Owner 2009-07-06 Operator changed from 9998, HISTORIC OWNER to 5680, TYPRO LTD
Change of Owner 2016-12-14 Operator changed from 7909, JOHN D OIL & GAS COMPANY to 9836, DAVID OIL COMPANY LLC
Record Last Modified 2016-12-14 GL=633.3, DF=640.3, KB=641.3 NO REPT.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2983 3014 18
2983 3014 18
2983 3014 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 750 Gal 0
H2O 0 1700 Bbl 57000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 JOHN D OIL & GAS COMPANY 11260.00 34.00 262
2010 JOHN D OIL & GAS COMPANY 7428.00 25.00 365
2011 JOHN D OIL & GAS COMPANY 4922.00 0.00 365
2012 JOHN D OIL & GAS COMPANY 3844.00 23.00 366
2013 GREAT PLAINS EXPLORATION LLC 3172.00 0.00 365
2014 GREAT PLAINS EXPLORATION LLC 2398.00 0.00 365
2015 GREAT PLAINS EXPLORATION LLC 1904.00 0.00 365
2016 DAVID OIL COMPANY LLC 954.00 0.00 61

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 JOHN D OIL & GAS COMPANY Brine 310 262
2010 JOHN D OIL & GAS COMPANY Brine 360 365
2011 JOHN D OIL & GAS COMPANY Brine 240 365
2012 JOHN D OIL & GAS COMPANY Brine 240 366
2013 GREAT PLAINS EXPLORATION LLC Brine 40 365
2014 GREAT PLAINS EXPLORATION LLC Brine 160 365
2015 GREAT PLAINS EXPLORATION LLC Brine 80 365
2016 JOHN D OIL & GAS COMPANY Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1261545588 2020-6-3 0:00:0 UP No Violations
-320034764 2018-4-24 0:00: UP No Violations 0.50
-373683026 2015-3-3 0:00:0 UP No Violations 1.00
0320034764 2018-04-24 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following: missing locks on load-lines and incorrect identification signage. At the time of this inspection, I noted the following: The load lines remained unlocked and unsecure. The ID signage continued to reflect the prior owner of the well. The new owner has made pledges to correct the deficiencies, but with no results at the time of this inspection. The well was shut-in and not in active production.
0373683026 2015-03-03 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well is located along a light industrial/commercial corridor on Tyler Blvd. in Mentor. The wellhead is located in the front portion of the building. The battery is located behind the facility at the referenced address. The wellhead plunger lift is located in a board-on-board enclosure. The battery is located in a separate chain-link enclosure, and is comprised of a 210-barrel production tank and 100-barrel brine tank, and separator unit. Load-outs are plugged and secure. The battery is shared with the #2-0199 well which is located near the battery. The ID signage identifies this well as the Worthington, which conflicts with other records. I will follow up with permits to resolve. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or problems. I did not observe any evidence of impact relating to on-going production activity.
0815225372 2017-12-06 UrbanProduction Wells Violations Noted I inspected the well location as part of routine inspection activity. The well and associated battery are located behind a commercial building, in a fringe area at the back. The battery is shared with the #2-199 well, which is located next to the battery. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery. Fittings and connections at the well and battery were secure and free from signs of leakage. The secondary containment was intact. I noted the following deficiencies: the load-lines were not locked as required. The ID signage, did not have correct information, the well name was incorrect, a had not been updated to reflect the change of ownership that occurred over 12 month prior to this inspection. The owner must place locks at the load-line valves and place compliant unit identification at the well within 30 days or be subject to additional enforcement. Contact Inspector Stephen Tompkins at 330-907-4647 with questions about this compliance notice.
1268100230 2009-11-09 Production Wells No Violations There were no violations found at the time.
1346528185 2018-12-03 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 815225372, regarding installation of load line locks and updated identification. During this inspection, it was observed that the well was equipped with a plunger lift assembly and not in production. The well was fenced and locked. Identification posted at the well still needed to have updated owner information added. The tank battery was comprised of one 210 BBL tank, one 100 BBL tank and a mechanical separator. The load lines from the tanks have not had locks added to them. The diked tank battery was fenced but still needed the identification to be updated with the current company information. The tank battery was shared with well 2-0199.
1456410251 2016-02-25 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with mechanical plunger lift system in a board-on-board enclosure. A tank battery comprised of one 210-barrel steel tank, one 100-barrel steel tank, a mechanical separator. The battery is partially enclosed in a chain-link fence. Fittings and connections were secure. Load lines were bull-plugged. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. The battery is shared with the #2-0199 well which is located adjacent to the battery.
1862694669 2012-12-17 UrbanProduction Wells No Violations The unit is comprised of a one-tank battery (1 210-barrel). The tank battery is shared with the #199 Unit. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-
2125858231 2019-6-7 0:00:0 UP No Violations
792816863 2019-11-19 0:00 UP No Violations
815225372 2017-12-6 0:00: UP No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0815225372 US-OH-129272 2017-12-28 ID (a-i)
0815225372 US-OH-129273 2017-12-28 LOCKS

For data sources see[9]

References