Well Details

Well ID: 34-081-20788
Loading map...
Country: United States
State: Ohio
County: Jefferson
Municipality: Smithfield Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001577
Farm/Lease Name: FALDOWSKI SW SMF JF
License Status: Producing
License Date: 2018-10-11
Spud Date: 2018-10-16
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2018-12-20
Well Total Depth: 20188.00 ft
Configuration: Horizontal
Latitude: 40.210000
Longitude: -80.800000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2018-10-11 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:10/11/2018, Expired Date:10/10/2020 12:00:00 PM, Drilling unit acres:269.88, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2018-12-20
Record Last Modified 2019-04-02
Correction to Well 2019-04-26 UPDATE TARGET/TAKE PER AS-DRILLED PLAT
Construction Permit Expires 2020-10-10

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
9874 20015 0
9874 20015 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1382426277 2018-12-3 0:00: DD No Violations 1.00
-1495788527 2018-12-5 0:00: CS No Violations 2.00
-2033634144 2018-12-18 0:00 DD No Violations 1.00
-2142130563 2019-5-16 0:00: CT No Violations 1.00
0262712614 2019-03-05 Completion Testing No Violations The inspection revealed the frac head is rigged up and waiting on the frac procedure. The intermediate casing pressure is 695 and the surface pressure is 0 psi
1048543323 2018-10-17 Casing String Witnessed No Violations
1382426277 2018-12-03 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson 584 drilling a 12.25 inch diameter hole at 7970. Estimated total depth for this section is 8725, which is 100 feet into the Reedsville. Hole is not making any water but Company man Michael Rollins said the Queenstown drank approximately 400 barrels of fresh water.
1495788527 2018-12-05 Casing String Witnessed No Violations On the day of my inspection I witnessed Patterson 584 drilled a 12.25 inch diameter hole to 8746. Wyoming casing ran 8739.7 feet of 40#, j-55 casing, with a 2.7 foot stick up. Shoe is at 8737 and shoe track in 89 feet long. DV tool set at 4499. Casing was centralized with 199 centralizers. Schlumberger was onsite with 40 barrels of 13 ppg mud push, 488 sacks of lead cement, and 790 sacks of tail cement for the first stage. Class A lead cement weighed 13.5 ppg with mudscale and has a yield of 1.67. Class A tail cement weighed 15.6 with mudscale and has a yield of 1.19. 30% excess pumped on first stage. Displacement was 655 barrels of oil based mud and was pumped by the rig. Floats held with 3 barrels back to the truck. Rig will drop bomb and circulate on well for three hours prior to pumping second stage. Second stage will consist of 40 barrels of 13pp mud push and 1425 sacks of class A tail cement. Cement weighs 15.6 ppg and has a yield of 1.19. Hole was filled with 12.2pp oil based mud prior to pumping jobs. Second stage was not witnessed.
1540490202 2018-10-25 Casing String Witnessed No Violations On the day of my inspection I witnessed the mine string cement job. Falcon 26 drilled a 24 inch diameter open hole to a depth of 235 feet. Previous casing set and cemented was 30 inch diameter conductor casing to a depth of 100 feet. Wyoming Casing ran 227 feet of 18.675 inch diameter casing, j-55, 87.5 lbs/foot, 4 foot stickup. Shoe track is 24 feet long. Cement Baskets were set at 162 feet. Coal encountered at 142 and then from 174-186 feet. C&J/Otex was onsite with 445 sacks of class A cement. Cement weighed with mudscale at 15.6 ppg and yield of 1.2. 50% excess ran in open hole. Cement displaced with 62 barrels of fresh water. 35 barrels of gel pumped ahead of cement. No cement returned to surface. Floats held with 1 barrel back to the truck. 120 feet of one inch diameter tubing ran down backside. 10 barrels of cement pumped down backside to set up on basket. An additional 63 barrels of cement was pumped down backside after a 2 hour wait time. 10 barrels of cement returned to surface weighing 15.3 ppg.
2033634144 2018-12-18 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson 584 had reached total depth of 20188. Wyoming casing is onsite running the 23#, p-110, 5.5 inch diameter casing. Mud weight is 15.5 ppg. Well is static. Company man Josh Delso says they will be cementing tomorrow.
2133050875 2019-05-29 Preliminary Restoration No Violations On the day of my inspection I witnessed several different contractors on site. A group of contractors is working on flowlines and the other is working on the pipeline/well connect corridor. Well has been drilled out and is awaiting flowback. Wellheads are on but flowlines have not been plumbed in. This well does not currently have tubing ran in it. It will be plumbed to produce from both sides of the wellhead. Annular pressure gauges are shut in and both read zero psi. Production equipment includes four line heaters, four GPUs, eight sand seperators, and two 500 barrel steel tanks in their own containment. Pad is stable and vegetated. Site meets requirements of 1509.072 (A) for preliminary restoration.
2142130563 2019-05-16 Completion Testing No Violations On the day of my inspection I witnessed Deep Well Snubbing unit #10 on location. They have already drilled out the frac plugs on this well and it is awaiting flowback operations. They are not running production tubing in the well. The 13.375x9.625 annular pressure is zero and the 9.625x5.5 annular pressure is 3300 psi. Company Man Cory Lewis said that the gauge reads 2000 psi in non-daylight hours and 3300 psi in the daylight. I asked him to get it bleed down and check/change the gauge. Burst pressure of 9.625 casing is 5750 psi.
262712614 2019-3-5 0:00:0 CT No Violations 0.20

For data sources see[4]