34-081-20694

Well Details

Well ID: 34-081-20694
Loading map...
Country: United States
State: Ohio
County: Jefferson
Municipality: Cross Creek Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001478
Farm/Lease Name: STONE SE CRC JF
License Status: Producing
License Date: 2017-08-11
Spud Date: 2017-04-13
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2017-08-22
Well Total Depth: 17780.00 ft
Configuration: Horizontal
Latitude: 40.340000
Longitude: -80.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-02-16 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:2/16/2017, Expired Date:2/16/2018 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2017-08-11 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:8/11/2017, Expired Date:8/11/2019 12:00:00 PM, Drilling unit acres:194.726, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2017-08-22
Correction to Well 2018-03-30 UPDATE TAKE/TARGET PER AS-DRILLED PLAT
Construction Permit Expires 2018-08-11
Completion Report Received 2019-01-17
Record Last Modified 2019-01-23

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2019-01-23 9810 9986 0
2019-01-23 17475 17611 0
17475 17611 0
9810 9986 0
9810 9986 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 01/12/2018 02/02/2018 9200 14,233,400.0 158803

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CI-150 FTSI Acid Corrosion Inhibitor Listed Below Green Line Listed Below 0 0 0
APB-1 FTSI Gel breaker Listed Below Green Line Listed Below 0 0 0
Water Supplied by Operator Base Fluid Water 7732-18-5 100 87.4152 118,707,000.0
FE-200A FTSI Iron Control Listed Below Green Line Listed Below 0 0 0
40/70 White FTSI Proppant Listed Below Green Line Listed Below 0 0 0
FRW-920 FTSI Friction Reducer - Zwitter ionic Listed Below Green Line Listed Below 0 0 0
SI-680 FTSI Scale Inhibitor Listed Below Green Line Listed Below 0 0 0
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,

3, 5-thiadiazine-2-thione.

533-74-4 24 0.011635 0
Copolymer of 2-Propenamide 69418-26-4 30 0.0200362 0
Silica, Quartz 14808-60-7 100 1.2911 0
Oleic Acid Diethanolamide 93-83-4 2 0.00133574 0
Ammonium Chloride 12125-02-9 1 0.000667872 0
Isotridecanol, ethoxylated 9043-30-5 2 0.00006596 0
Methanol 67-56-1 90 0.00070683 0
Petroleum Distillate 64742-47-8 55 0.00181403 0
Sodium Hydroxide 1310-73-2 23 0.0111502 0
Citric Acid 77-92-9 30 0.00147182 0
Propargyl Alcohol 107-19-7 5 0.00003927 0
Thiourea-formaldehyde Copolymer 68527-49-1 10 0.00007854 0
Ammonium Persulfate 7727-54-0 100 0.000358419 0
Hydrocarbon Proprietary 3 0.00002356 0
N-olefins Proprietary 3 0.00002356 0
Fatty Acids, Tall Oil 61790-12-3 10 0.00007854 0
Alcohol Ethoxylate Surfactants Trade Secret 2 0.00133574 0
Alcohol Ethoxylate Surfactants Proprietary 10 0.00007854 0
Guar gum 9000-30-0 55 0.00181403 0
Sodium Chloride 7647-14-5 5 0.00178613 0
Silica, Quartz 14808-60-7 100 10.2725 0
Suspending Agent 1302-78-9 5 0.000164912 0
Methyl Alcohol 67-56-1 15 0.00535839 0
Quartz 14808-60-7 4 0.000131929 0
Hydrotreated Petroleum Distillate 64742-47-8 25 0.0166968 0
Hydrogen Chloride 7647-01-0 7.5 0.0645691 0
Acetic acid 64-19-7 40 0.00196242 0
ORGANICPHOSPHONIC ACIDS SALTS Trade Secret 20 0.00714452 0
Raffinates, Sorption Process 64741-85-1 55 0.00181403 0
0.1%-7.5% HCL FTSI Acid Listed Below Green Line Listed Below 0 0 0
Other Chemical(s) Listed Above See Trade Name(s) List Water 7732-18-5 45 0.00220772 0
Water 7732-18-5 92.5 0.796352 0
Water 7732-18-5 80 0.0285781 0
Water 7732-18-5 55 0.0266635 0
Water 7732-18-5 50 0.0333936 0
100 Mesh Sand FTSI Proppant Listed Below Green Line Listed Below 0 0 0
HVG-1 4.0 FTSI Water gelling agent Listed Below Green Line Listed Below 0 0 0
ICI-3240 FTSI Biocide Listed Below Green Line Listed Below 0 0 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2018-02-02 H2O 15 7306 Bbl 350011 Frac Tech Services STAGE 1/45

STAGES 2-45 SEE IMAGES

2018-02-02 H2O 15 6880 Bbl 349368 Frac Tech Services STAGE 46/46

STAGES 2-45 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC 5045832 0 262
2019 ASCENT RESOURCES UTICA LLC 713810 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC Brine 36742 262
2019 ASCENT RESOURCES UTICA LLC Brine 1825 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1862895797 2017-4-13 0:00: CS No Violations 3.50
-21754392 2017-8-16 0:00: DD No Violations 1.50
-655013668 2020-1-15 0:00: PW No Violations 1.00
0021754392 2017-08-16 Drill / Deepen / Reopen No Violations On the date of my inspection I found Patterson drilling rig 577 tripping out of the hole after reaching their total depth for this section of 8657 feet. Ascent plans to run the 9.625 inch casing this afternoon and cement on 8/17. This is a follow up inspection from 8/14, when I found a brine saturated area on the pad. The leak has not been fixed yet. The water tested for between 1127 and 1222 parts per million using Quantabs on 8/14 and tested for 1694 parts per million today. I spoke with the Ascent company man about the leak and he called a containment company while I was there to come out to work on the issue.
0543261344 2017-04-13 Casing String Witnessed No Violations Onsite with Supervisor Mike Moreland and Inspector Scott Scheiner to view the cementing of conductor casing. See Scotts report for this date.
0739239165 2017-12-13 Completion Testing No Violations On the date of my inspection I found a well maintained access road with a locked gate. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. There are 4 recently drilled wells on the pad surrounded by concrete barriers. The wells have not been hydraulically fractured yet. Containment for frac operations has been placed around the wellheads. There are currently 8 frac tanks, a trailer, a forklift, and walls for an above ground storage tank onsite. The two 500 barrel tanks for production have been installed and are within a metal dike.
0840471632 2018-02-23 Preliminary Restoration No Violations On the day of my inspection I witnessed Fractech was onsite under direction of Ascent Company man Larry Jennings. This pad is splitting water with the Giusto pad, and the other pad is currently receiving water for frac. Stage 1 is finished. Received call from Mr. Niece (ODOT aviation) on 2/21 in regards to crane not having a permit from ODOT. Pad is within 10000 feet of jefferson airpark and ODOT has permits for erections that close to airport. A temporary light was installed on crane. Permanent light is supposed to arrive on location today or tomorrow. Outslope of pad is vegetated and stable. Lease road is stable. Site meets requirements of ORC 1509.072A for preliminary restoration.
1087202859 2019-7-22 0:00: UL No Violations 1.00
1496226847 2017-05-31 Casing String Witnessed No Violations I am on site to witness the running and cementing of 13.375 inch surface casing. Falcon Rig 26 drilled a 17.5 inch diameter hole to a depth of 1435 feet and set 1415 feet of 13.375 inch 61 pound per foot casing. O-Tex established circulation with fresh water, pumped 1500 sacks of class A cement, 1.19 yield and 15.6 pound per gallon, 2 percent calcium chloride, 0.25 pound cello flake per sack. Approximately 80 barrels of cement returned to surface. The wiper plug landed and pressure was increased to approximately 500 pounds per square inch (psi) over pump pressure, the casing held approximately 1050 psi for 5 minutes.
1503409285 2017-08-22 Drill / Deepen / Reopen No Violations On the date of my inspection I found Patterson drilling rig 577 performing the clean up cycle on the hole before coming out to run the 5.5 inch production casing. They reached their total depth of 17778 last night. Ascent plans to run casing on 8/23 and expects to cement the production casing on 8/24. There is standing water along the edges of the pad on top of the french drains due to heavy rains 3 days ago. Ascent is having trouble getting water trucks out to remove the water. They are unable to release the water due to excessive chlorides. The containment breach near the flare has been repaired. The pad is surrounded by healthy vegetation. The pad drains are in the closed position and do not appear to be leaking. Currently a pipeline crew is preparing the right of way adjacent to the pad.
1739062903 2017-08-14 Drill / Deepen / Reopen No Violations On the date of my inspection I found Patterson drilling rig 577 drilling the intermediate section of this well at approximately 6200 feet. Ascent anticipates reaching their total depth for this string tomorrow and running casing on 8/16/17. During my inspection I found multiple punctures and tears in the containment near the catwalk. I found a saturated area on the pad between the Marybeth and the flare that appears to be leaking from within the containment. The water tested for between 1127 and 1222 parts per million using Quantabs. I spoke with the Ascent company man about the issues and he indicated that he would call the containment contractor out to repair the damaged areas today and would have them locate the leak that the brine is coming from. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. The pad drain valves are in the closed position and do not appear to be leaking.
1862895797 2017-04-13 Casing String Witnessed No Violations I am on site today to witness the cementing of 30 inch conductor casing. Precision Drilling drilled a 36 inch diameter hole to a depth of 100 feet and ran 100 feet of 30 inch diameter 118 pound per foot conductor casing. O-Tex pumped 400 sacks of class H cement, 1.2 yield, 15.6 pounds per gallon with 2 percent Calcium Chloride and 0.25 pound per sack flow seal. O-Tex then displaced with 75 barrels of water, leaving 10 feet of cement in the casing. I witnessed good cement return to surface and remain static
543261344 2017-4-13 0:00: CS No Violations 2.50
739239165 2017-12-13 0:00 CT No Violations 0.30
840471632 2018-2-23 0:00: PL No Violations 1.00

For data sources see[10]