Well Details

Well ID: 34-075-25107
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Hardy Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: LEIGH TRACI
License Status: Producing
License Date: 1993-05-28
Spud Date: 1993-06-30
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 1993-07-12
Well Total Depth: 6018.00 ft
Configuration: Vertical
Latitude: 40.560000
Longitude: -81.880000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1993-05-28 Issued Date 5/28/93 Expired Date 5/28/94 Acres 0040000 Tool Type RTAF Proposed Formation ROSE RUN Proposed Depth 06018 Proposed Drill Depth 06018
Original Spud 1993-07-02
Completed 1993-07-12
Reached Total Depth 1993-07-12
CO 1993-07-30 2547 TATUM PETROLEUM CORP GeoDate 5/28/93
Completion Report Received 1993-10-04
Construction Permit Expires 1994-05-28
Change of Owner 2005-07-21 Operator changed from 2547, TATUM PETROLEUM CORP to 1388, NORTH COAST ENERGY INC
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Change of Owner 2017-05-01 Operator changed from 7578, ENERVEST OPERATING LLC, to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-05-01

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5762 5882 0
5762 5882 0
2006-09-11 5777 5878 88
5777 5878 88
5762 5882 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 20 2000 Gal 0 2000 GAL 20% FE ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 TATUM PETROLEUM CORP 63349.00 6399.00 156
1994 TATUM PETROLEUM CORP 148711.00 13092.00 365
1995 TATUM PETROLEUM CORP 10309.00 7431.00 365
1996 TATUM PETROLEUM CORP 93138.00 4020.00 365
1997 TATUM PETROLEUM CORP 58506.00 2253.00 365
1998 TATUM PETROLEUM CORP 25046.00 813.00 330
1999 TATUM PETROLEUM CORP 19544.00 1324.00 365
2000 TATUM PETROLEUM CORP 14737.00 966.00 343
2001 TATUM PETROLEUM CORP 10391.00 824.00 365
2002 TATUM PETROLEUM CORP 9610.00 927.00 365
2003 TATUM PETROLEUM CORP 7419.00 415.00 365
2004 TATUM PETROLEUM CORP 4126.00 257.00 365
2005 TATUM PETROLEUM CORP 973.00 0.00 273
2006 EXCO - NORTH COAST ENERGY INC 42.00 86.00 365
2007 EXCO - NORTH COAST ENERGY INC 0.00 0.00 0
2008 EXCO - NORTH COAST ENERGY INC 300.00 0.00 366
2009 EXCO - NORTH COAST ENERGY INC 183.00 0.00 365
2010 ENERVEST OPERATING LLC 27.00 77.00 365
2011 ENERVEST OPERATING LLC 1253.00 63.00 0
2012 ENERVEST OPERATING LLC 23599.00 1011.00 366
2013 ENERVEST OPERATING LLC 14231.00 1021.00 365
2014 ENERVEST OPERATING LLC 5510.00 754.00 365
2015 ENERVEST OPERATING LLC 3570.00 723.00 365
2016 ENERVEST OPERATING LLC 2844.00 722.00 350
2017 M & R INVESTMENTS OHIO LLC 958.00 0.00 365
2018 M & R INVESTMENTS OHIO LLC 999.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 TATUM PETROLEUM CORP Brine 30 156
1994 TATUM PETROLEUM CORP Brine 26 365
1995 TATUM PETROLEUM CORP Brine 0 365
1996 TATUM PETROLEUM CORP Brine 299 365
1997 TATUM PETROLEUM CORP Brine 475 365
1998 TATUM PETROLEUM CORP Brine 1388 330
1999 TATUM PETROLEUM CORP Brine 672 365
2000 TATUM PETROLEUM CORP Brine 313 343
2001 TATUM PETROLEUM CORP Brine 42 365
2002 TATUM PETROLEUM CORP Brine 170 365
2003 TATUM PETROLEUM CORP Brine 0 365
2004 TATUM PETROLEUM CORP Brine 0 365
2005 EXCO - NORTH COAST ENERGY INC Brine 40 92
2006 EXCO - NORTH COAST ENERGY INC Brine 0 365
2007 EXCO - NORTH COAST ENERGY INC Brine 0 0
2008 EXCO - NORTH COAST ENERGY INC Brine 0 366
2009 EXCO - NORTH COAST ENERGY INC Brine 0 365
2010 ENERVEST OPERATING LLC Brine 109 365
2011 ENERVEST OPERATING LLC Brine 281
2012 ENERVEST OPERATING LLC Brine 3807 366
2013 ENERVEST OPERATING LLC Brine 2232 365
2014 ENERVEST OPERATING LLC Brine 2068 365
2015 ENERVEST OPERATING LLC Brine 1172 365
2016 ENERVEST OPERATING LLC Brine 967 350
2017 ENERVEST OPERATING LLC Brine 0 193
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1574872648 2011-11-10 0:00 PW No Violations
-1659724487 2019-3-19 0:00: PW No Violations 1.50
-1734051500 2013-8-12 0:00: PW No Violations
-1850995913 2020-3-2 0:00:0 PW No Violations 0.50
-1928516097 2015-2-20 0:00: PW No Violations
-1974992829 2018-5-15 0:00: PW No Violations
-246507760 2018-2-21 0:00: PW No Violations 1.80
-40622616 2016-12-21 0:00 PW No Violations
-869376588 2004-11-4 0:00: PL No Violations
0000014616 Preliminary Restoration No Violations PASSED Y WITNESSED 5/18/94 INSPECTOR WILLIAM R. DUNFEE DATE 05/1819/94 DATA FROM OLD VAX INFO
0040622616 2016-12-21 Production Wells No Violations

-. Will put a rig back on it after the first of the year.

0246507760 2018-02-21 Production Wells No Violations On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing. The well is operated by a pumping unit, with an electric motor. The production equipment is made up of two 210 bbl. steel tanks, and a horizontal separator. The tank is properly identified. The production reporting is up to date. The well location has tubing and rods have that have been out of the wellbore for 1 1/2 years according to the land owner. The well has some down hole issues and they are unable to run the tubing back into the well. The land owner stated that the 4 1/2 inch diameter casing is parted at a depth of 2800 feet. I contacted John Raber with M&R Investments to remove the tubing and rod from the location due to unsafe conditions for the property owner. I also requested that a plan of action for the be submitted to within two weeks as to plug or repair the well.
0255315224 2019-03-19 Production Wells No Violations This is a follow up inspection to compliance notice 1529323014 issued on 06/20/2018. The compliance has been resolved on the safety issue, the tubing and rods have been removed from location, but the safety issue has come back into play. The pumping unit is being dismantled, and all the parts are laying on location. The casing valve is in the off position. As of this date M&R have not yet scheduled a time to verify the casing integrity and verify the production.
0430870975 2003-04-15 Production Wells No Violations no violation
0869376588 2004-11-04 Preliminary Restoration No Violations restoration ok
1099931487 2004-11-04 Production Wells No Violations no violation
1206829992 2011-09-29 Production Wells No Violations Producing, no problems noted.
1320779749 2011-11-08 Production Wells No Violations Workover is in progress. Adding rods and will set a pumping unit. No problems noted.
1348324081 2020-5-14 0:00: PW No Violations 0.50
1420664566 2020-9-29 0:00: PW No Violations 0.50
14616 PL No Violations
1529323014 2018-06-18 Production Wells Violations Noted This is a follow up inspection to the one I performed on 5/15/2018. I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing. The well is operated by a pumping unit, with an electric motor. The production equipment is made up of two 210 bbl. steel tanks, and a horizontal separator. The tank is properly identified. The production reporting is up to date. The well location has tubing and rods that have been pulled out of the wellbore, and left on location for 2 years according to the land owner. I believe the well has some down hole issues and they are unable to run the tubing and rods back into the well. I contacted John Raber with M&R Investments two times to remove the tubing and rod from the location due to unsafe conditions for the property owner. As of this date it has not been removed. I request that M&R Investments verify the integrity of the 4 1/2 inch diameter casing, and the 8 5/8 inch diameter. I also request that M&R verify the production of the well.
1530791818 2018-07-05 Production Wells No Violations This is a follow up inspection to compliance notice 1529323014 issued on 06/20/2018. The compliance has been resolved, the tubing and rods have been removed from location. The pumping unit is being dismantled to be move off location. It appears that M&R is preparing to plug the well. As of this date they have not yet scheduled a time to verify the casing integrity and verify the production.
1539349018 2018-10-12 Production Wells No Violations This is a follow up inspection to compliance notice 1529323014 issued on 06/20/2018. The compliance has been resolved on the safety issue, the tubing and rods have been removed from location. The pumping unit is being dismantled. The casing valve is in the off position. As of this date they have not yet scheduled a time to verify the casing integrity and verify the production.
1572982920 2019-11-5 0:00: PW No Violations 1.00
1574872648 2011-11-10 Production Wells No Violations The rods have been run in well and the pumping unit set. Waiting on electric to be installed.
1659724487 2019-03-19 Production Wells No Violations This is a follow up inspection to compliance notice 1529323014 issued on 06/20/2018. I met with Michael S. Miller the property owner, he stated he wishes to file a complaint at this time and wants the well plugged and abandon. I completed the complaint and the ID is 6105. The compliance has been resolved on the safety issue, the tubing and rods have been removed from location, but the safety issue has come back into play. The pumping unit is being dismantled, and all the parts are laying on location. The casing valve is in the off position. As of this date M&R have not yet scheduled a time to verify the casing integrity and verify the production.
1734051500 2013-08-12 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1750690943 2015-10-27 Production Wells No Violations A Berry Well Service rig is on location stripping the rods and tubing. There were no problems noted at the time of the inspection.
1774167031 2020-7-16 0:00: PW No Violations 0.30
1928516097 2015-02-20 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection. The unit was pumping at the time of the inspeciton.
1974992829 2018-05-15 Production Wells No Violations This is a follow up inspection to the one I performed on 2/21/2018. I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing. The well is operated by a pumping unit, with an electric motor. The production equipment is made up of two 210 bbl. steel tanks, and a horizontal separator. The tank is properly identified. The production reporting is up to date. The well location has tubing and rods have that have been out of the wellbore for 1 1/2 years according to the land owner. The well has some down hole issues and they are unable to run the tubing back into the well. The land owner stated that the 4 1/2 inch diameter casing is parted at a depth of 2800 feet. I contacted John Raber with M&R Investments to remove the tubing and rod from the location due to unsafe conditions for the property owner. I also requested that a plan of action for the be submitted to plug or repair the well.
255315224 2019-3-19 0:00: PW No Violations 1.80
329895894 2019-9-24 0:00: PW No Violations
430870975 2003-4-15 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1529323014 US-OH-114593 2018-06-20 9-9-02 General Safety

For data sources see[9]