34-073-21157

Well Details

Well ID: 34-073-21157
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Green Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: HUTCHINS G L & J F
License Status: Producing
License Date: 1992-08-07
Spud Date: 1965-10-07
Spud Drilling Contractor:
Final Drill Date: 1965-11-27
Well Total Depth: 2869.00 ft
Configuration: Vertical
Latitude: 39.520000
Longitude: -82.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1965-10-07 GL=787.73
Completed 1965-11-27 GL=787.73
Reached Total Depth 1965-11-27 GL=787.73
CO 1992-08-07 566 GRIM PAUL A GeoDate 8/7/92
Unknown 1992-08-07 Issued Date 8/7/92 Expired Date 8/7/93 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Construction Permit Expires 1993-08-07 GL=787.73
Change of Owner 2001-10-29 Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP.
Record Last Modified 2013-10-03 GL=787.73

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1160 Bbl 35000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 GRIM PAUL A 546.00 76.00 365
1995 GRIM PAUL A 0.00 3350.00 365
2002 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2003 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2004 HOCKING HILLS ENERGY AND WELL 0.00 0.00 180
2005 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365
2006 HOCKING HILLS ENERGY AND WELL 11.00 0.00 365
2007 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2008 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2009 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2010 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2011 HOCKING HILLS ENERGY AND WELL 0.00 43.00 0
2012 HOCKING HILLS ENERGY AND WELL 0.00 118.00 366
2013 HOCKING HILLS ENERGY AND WELL 0.00 17.00 365
2014 HOCKING HILLS ENERGY AND WELL 0.00 17.00 365
2015 HOCKING HILLS ENERGY AND WELL 0.00 54.00 365
2016 HOCKING HILLS ENERGY AND WELL 0.00 54.00 365
2017 HOCKING HILLS ENERGY AND WELL 0.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 GRIM PAUL A Brine 293 365
1995 GRIM PAUL A Brine 60 365
2002 HOCKING HILLS ENERGY AND WELL Brine 0 0
2003 HOCKING HILLS ENERGY AND WELL Brine 0 0
2004 HOCKING HILLS ENERGY AND WELL Brine 55 180
2005 HOCKING HILLS ENERGY AND WELL Brine 90 365
2006 HOCKING HILLS ENERGY AND WELL Brine 120 365
2007 HOCKING HILLS ENERGY AND WELL Brine 0 0
2008 HOCKING HILLS ENERGY AND WELL Brine 0 0
2009 HOCKING HILLS ENERGY AND WELL Brine 0 0
2010 HOCKING HILLS ENERGY AND WELL Brine 0 0
2011 HOCKING HILLS ENERGY AND WELL Brine 70
2012 HOCKING HILLS ENERGY AND WELL Brine 480 366
2013 HOCKING HILLS ENERGY AND WELL Brine 490 365
2014 HOCKING HILLS ENERGY AND WELL Brine 315 365
2015 HOCKING HILLS ENERGY AND WELL Brine 0 365
2016 HOCKING HILLS ENERGY AND WELL Brine 0 365
2017 HOCKING HILLS ENERGY AND WELL Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1281833926 2006-12-4 0:00: PW No Violations
-131141135 2009-11-30 0:00 AM No Violations
-1403397393 2009-5-15 0:00: PW No Violations
-1470185559 2009-10-13 0:00 PW No Violations
-1598306714 2006-7-19 0:00: AD No Violations
-1714462173 2010-3-1 0:00:0 PW No Violations
-1833883954 2012-10-30 0:00 PW No Violations 2.00
-330845545 2009-12-10 0:00 AM No Violations
-681121475 2011-5-2 0:00:0 PW No Violations 2.00
-979152060 2011-5-2 0:00:0 PW No Violations 2.00
0131141135 2009-11-30 Administrative Inspection No Violations Received call today from landowner whom, expressed displeasure with the well owners failure to comply. Spoke with Mr. Doug Kitchen today, in the field, regarding the flowline burial for this well and the non-production from Permit No. 1206. Mr. Kitchen was asked how much more time he would need and states that line burial could be completed by 12/11/2009.
0330845545 2009-12-10 Administrative Inspection No Violations A follow-up administrative inspection, in the field, was conducted with Mr. Robert Stonerock, South Region Oil & Gas Supervisor. Reviewed and discussed location of line burial. Chieftain Energy has failed to meet deadline set by NOV, and Compliance Schedule. During a 11/30/2009 meeting, Mr. Kitchen agreed to an 12/11/2009 deadline.
0681121475 2011-05-02 Production Wells No Violations FOLLOW UP TO NOV # -979152060 Upon inspection it was observed that identification was not present on the well head or tank battery, all valves were closed at the well head and tank battery, there was no motor on the pump jack, the polish rod was dry and had oxidation on it, there was a cut in the flow line and the earthen dike was 2/3 full of water (there had been substantial rainfall in the previous days). Vegetation and amphibian life were also observed within the dike as well as an oil sheen on top of the water. The chloride content of the water in the dike, when tested with low range Quantab titrators revealed a reading of 3.6 which is 143 ppm(mg/L). When researching the well in RBDMS, there were no production records for 2010, and the well had not produced anything since 2007. Well needs to be identified, and placed back in production or placed in temporary inactive status. All fluids need to be removed from dike and hauled away. Production reports need submitted to Columbus for 2010. Failure to comply will result in forfeiture of bond. Photographs were obtained at time of inspection. Spoke with Doug Kitchen on 5/3/2011 at 5:03 PM and he stated that he has bills of sale for gas from this well.
0979152060 2011-05-02 Production Wells Violations Noted Upon inspection it was observed that identification was not present on the well head or tank battery, all valves were closed at the well head and tank battery, there was no motor on the pump jack, the polish rod was dry and had oxidation on it, there was a cut in the flow line and the earthen dike was 2/3 full of water (there had been substantial rainfall in the previous days). Vegetation and amphibian life were also observed within the dike as well as an oil sheen on top of the water. The chloride content of the water in the dike, when tested with low range Quantab titrators revealed a reading of 3.6 which is 143 ppm(mg/L). When researching the well in RBDMS, there were no production records for 2010, and the well had not produced anything since 2007. Well needs to be identified, and placed back in production or placed in temporary inactive status. All fluids need to be removed from dike and hauled away. Production reports need submitted to Columbus for 2010. Failure to comply will result in forfeiture of bond. Photographs were obtained at time of inspection. Spoke with Doug Kitchen on 5/3/2011 at 5:03 PM and he stated that he has bills of sale for gas from this well.
1154608432 2006-07-19 Annular Disposal Violations Noted An inspection was conducted at the facility owned by Chieftain Energy Corp on 7/19/2006. During the inspection, it was noted that gas was leaking at the wellhead and no identification could be found. The area surrounding the tank battery showed signs of a spill, which may have affected a nearby creek. At the time of the inspection, oil was not observed upstream nor downstream of the spill. It was noted however, that a dike has been built. The ID located at the tank battery must be corrected and show the correct area code and permit number.
1239026239 2009-03-18 Annular Disposal Violations Noted A complaint was received alleging non-production and flowline burial. An inspection revealed that the well is idle. The well does contain production equipment to include a pumping unit, but a valve was observed closed. The well consists of just one flowline therefore, product from the tubing and casing would be routed through this line. Chieftain Energy obtained ownership of this well in 2001 from Mr. Paul Grim. From 2002 to 2005, RBDMS records indicate that there was no oil or gas production. Prior to 2002, the only years that production had been reported was 1985 and 1995. In both of these years, oil had been produced. In 2006, Chieftain Energy reported gas production. Currently, no statement of production of oil, gas and brine has been submitted for 2007 and 2008. Identification was not found at the well. A meter located near the tank battery contained a chart (no sign of production, which stated February 2009. A valve was observed closed on the gas line routed to a separator at this location. The 2 diameter plastic flowline from this well is routed through the pasture field to tank battery. The flowline will need to be buried. Oily soil and fluid were observed inside the dike.
1269285393 2013-10-22 Production Wells No Violations Compliance notice follow up, the well is in compliance. This satisfies the compliance notice.
1281833926 2006-12-04 Production Wells No Violations A follow-up inspection conducted on 12/4/2006 revealed that the previously noted violations have been resolved.
1403397393 2009-05-15 Production Wells No Violations A follow-up inspection revealed non-compliance.
1453602673 2006-09-13 Annular Disposal No Violations A follow-up inspection was conducted on 9/13/2006. During the inspection, it was noted that the previously noted violations have not been resolved. Chieftain Energy Corp. was contacted by telephone on 9/13/2006, and informed of the current status.
1470185559 2009-10-13 Production Wells No Violations A follow-up inspection to Notice of Violation and Compliance Agreement Schedule composed on 7/14/2009 with a deadline of 10/1/2009 revealed non-compliance. Prior to agreement, the NOV deadline was 5/7/2009. Chieftain Energy has failed to bury the remaining flowline. Approximately 200 has been buried, but approx 500 still remains on top of ground located in pasture field. Observed meter with chart dated 9/30/09 showing gas production from this well.
1547044714 2019-01-09 Production Wells No Violations I conducted an inspection on this well today accompanied by landowner Barney Cook. My inspection revealed that the well was equipped with rods and tubing but no pumping unit. The well was not capable of production and did not show signs of recent production. This well produces into a shared tank battery with API permit number 1207. The tank battery consists of (2) 100 barrel tanks and a knockout tank inside an earthen dike. Identification was posted at the tank battery but not at the well. The last year for reported commercial production was 2016 in which Hocking Hills Energy and Well Service reported 54 barrels of oil. I took two photos of the well. The well owner/operator shall submit a written plugging schedule to Brandon Mitchell at 5880 Memory Road Zanesville, Ohio 43701-9553 within 30 days, per ORC 1509:13(B)(7), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. Time of inspection: 8:55 AM. Weather: 28 degrees F, Snowing
1598306714 2006-07-19 Annular Disposal No Violations C & P at tank battery, no ID, Brent Bear will issue NOV.
1706244953 2009-05-01 Production Wells No Violations A follow-up inspection revealed that the company is burying the flowline between the well and the tank. It was also noted that the oil has been removed from the dike.
1714462173 2010-03-01 Production Wells No Violations A follow-up inspection revealed compliance. Note: snow cover at time of inspection.
1833883954 2012-10-30 Production Wells No Violations Pumping unit has been removed from well. Rods and tubing are present. I spoke with Mr. Dale Campbell about this well and he stated that he hadnt decided what to do with it yet. I will follow up with him next week.
1844187176 2018-02-27 Production Wells No Violations I received a request from Mr. Neil Hinton to determine the status of this well. The well consists of a pumping unit and 1-100 barrel tank. The well had a legible identification. Mr. Hinton is planning on building a structure on the property and wanted to know if the well would have any environmental issues associated with building on the property. The well is in compliance and I have contacted Mr. Hinton to relay this information.
2077060508 2020-8-26 0:00: PW No Violations 1.00
572758622 2019-7-11 0:00: PW No Violations 0.20

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0979152060 US-OH-131245 2011-05-02 Forfeiture of bond
0979152060 US-OH-131246 2011-05-02 Failure to legibly identify well
0979152060 US-OH-131247 2011-05-02 No SPCC dike/or failure to keep dike free of water or oil
0979152060 US-OH-131248 2011-05-02 Well shall be plugged
0979152060 US-OH-131249 2011-05-02 Nonproduction; well shall be plugged or placed in temporary inactive status
0979152060 US-OH-131250 2011-05-02 Statement of annual production not filed
1154608432 US-OH-104042 2006-08-07 Well not equipped to prevent escape of oil and/or gas
1154608432 US-OH-104043 2006-08-07 Failure to legibly identify well
1154608432 US-OH-104044 2006-08-07 Improperly located oil tank
1154608432 US-OH-104045 2006-08-10 No SPCC dike/or failure to keep dike free of water or oil
1239026239 US-OH-106364 2009-04-06 Failure to properly bury pipelines
1239026239 US-OH-106365 2009-04-06 Failure to legibly identify well
1239026239 US-OH-106366 2009-04-06 Well shall be plugged
1239026239 US-OH-106367 2009-04-06 Failure to keep SPCC dike/pit free of brine and other wastes

For data sources see[8]

References