34-073-20246

Well Details

Well ID: 34-073-20246
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Benton Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: STATE OF OHIO
License Status: Final Restoration
License Date: 2011-10-12
Spud Date: 1950-05-03
Spud Drilling Contractor:
Final Drill Date: 1950-06-06
Well Total Depth: 2452.00 ft
Configuration: Vertical
Latitude: 39.440000
Longitude: -82.560000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1950-05-03
Completed 1950-06-06
Reached Total Depth 1950-06-06
APP 2011-10-12 Proposed Formations:CLINTON, Issued Date:10/12/2011, Expired Date:10/11/2013 12:00:00 PM, Drilling unit acres:7396, Proposed Well Type:SO, Proposed Well Class:
Plugged/Abandoned 2011-12-08
Record Last Modified 2013-03-14
Construction Permit Expires 2013-10-11

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0573102565 2011-12-07 Plug / Plug Back No Violations Witnessed plug being pumped on top of the bottom plug.
0753620977 2012-05-10 Final Restoration No Violations Final restoration meets 1509.072 requirements. Stone was left on the lease road as per instruction from The Ohio Division of Forestry.
0983135903 2011-12-06 Plug / Plug Back No Violations Bottom hole plug was tagged at 1605ft. 7 inch casing was free-pointed at 1500 ft.
1323983318 2011-12-05 Plug / Plug Back No Violations Company drilled through composite plug to reach total depth. Bottom plug was pumped through drill pipe. 75 sacks were pumped, they pulled 13 joints, 75 more sacks were pumped, then 16 joints were pulled and they reverse circulated.
1324042656 2011-12-08 Plug / Plug Back No Violations Cement was tagged at 980 ft. Two attempts were made to cut and pull the surface casing. The first was at 700 ft., and it would not pull, and the second at 433 ft. When company attempted to pull the second time, the casing parted at about 10 ft. Drill pipe was then set at 845 ft., then cement was pumped to surface. Drill pipe was pulled and cement fell back. Well was topped off, and cement stayed.
1616733128 2011-11-22 Plug / Plug Back No Violations Witnessed the setting of composite plug. The plug was set at 2391. The purpose of this plug is to keep the well safe while service rig is setting up and getting ready to plug the well. Composite plug will be drilled out. Log was also ran on well by Baker Hughes.
573102565 2011-12-7 0:00: PB No Violations 3.00
753620977 2012-5-10 0:00: FR No Violations 1.50
983135903 2011-12-6 0:00: PB No Violations 1.50