If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-067-20823 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.31,"lon":-81.26,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Harrison | |
Municipality: Franklin Township | |
Operator Name: MCMILLEN KAY | |
Well Pad ID: | |
Farm/Lease Name: MCMILLEN CARL | |
License Status: Domestic Well | |
License Date: 1987-12-03 | |
Spud Date: 1987-12-16 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1987-12-20 | |
Well Total Depth: 5830.00 ft | |
Configuration: Vertical | |
Latitude: 40.310000 | |
Longitude: -81.260000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1987-12-03 | 182 BELDEN & BLAKE CO GeoDate 12/3/87 |
Oil and Gas | 1987-12-03 | Issued Date 12/3/87 Expired Date 12/2/88 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05830 Proposed Drill Depth 05830 |
Original Spud | 1987-12-16 | CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM S & S ENERGY CORP. #5660 TO OWNER ON 12/30/2015 CM. |
Completed | 1987-12-20 | CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM S & S ENERGY CORP. #5660 TO OWNER ON 12/30/2015 CM. |
Reached Total Depth | 1987-12-20 | CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM S & S ENERGY CORP. #5660 TO OWNER ON 12/30/2015 CM. |
Completion Report Received | 1988-03-04 | CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM S & S ENERGY CORP. #5660 TO OWNER ON 12/30/2015 CM. |
Construction Permit Expires | 1988-12-02 | CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM S & S ENERGY CORP. #5660 TO OWNER ON 12/30/2015 CM. |
Change of Owner | 2002-08-06 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC |
Change of Owner | 2005-07-08 | Operator changed from 1966, PETROX, INC to 5660, S & S ENERGY CORPORATION |
Change of Owner | 2015-12-30 | Operator changed from 5660, S & S ENERGY CORPORATION to 9613, MCMILLEN KAY |
Record Last Modified | 2017-02-15 | CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM S & S ENERGY CORP. #5660 TO OWNER ON 12/30/2015 CM. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5504 | 5626 | 0 |
5504 | 5626 | 0 | |
2006-09-11 | 5547 | 5624 | 3 |
5547 | 5624 | 3 | |
5504 | 5626 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 92170 Gal | 80000 | FRAC: H2O,SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1990 | BELDEN & BLAKE CORPORATION | 1326.00 | 0.00 | 199 |
1991 | BELDEN & BLAKE CORPORATION | 4045.00 | 0.00 | 365 |
1992 | BELDEN & BLAKE CORPORATION | 3417.00 | 135.00 | 341 |
1993 | BELDEN & BLAKE CORPORATION | 4497.00 | 0.00 | 356 |
1994 | BELDEN & BLAKE CORPORATION | 2229.00 | 103.00 | 351 |
1995 | BELDEN & BLAKE CORPORATION | 2079.00 | 0.00 | 352 |
1996 | BELDEN & BLAKE CORPORATION | 1885.00 | 85.00 | 354 |
1997 | BELDEN & BLAKE CORPORATION | 2076.00 | 0.00 | 341 |
1998 | BELDEN & BLAKE CORPORATION | 1896.00 | 92.00 | 322 |
1999 | BELDEN & BLAKE CORPORATION | 1600.00 | 59.00 | 268 |
2000 | BELDEN & BLAKE CORPORATION | 1551.00 | 0.00 | 359 |
2001 | BELDEN & BLAKE CORPORATION | 1286.00 | 44.00 | 359 |
2002 | PETROX, INC | 937.00 | 0.00 | 56 |
2003 | PETROX, INC | 947.00 | 45.00 | 365 |
2004 | PETROX, INC | 1558.00 | 0.00 | 365 |
2005 | PETROX, INC | 1241.00 | 66.00 | 180 |
2006 | S & S ENERGY CORP | 1314.00 | 27.00 | 365 |
2007 | S & S ENERGY CORP | 1430.00 | 0.00 | 365 |
2008 | S & S ENERGY CORP | 1282.00 | 37.00 | 365 |
2009 | S & S ENERGY CORP | 1545.00 | 35.00 | 365 |
2010 | S & S ENERGY CORP | 1143.00 | 0.00 | 365 |
2011 | S & S ENERGY CORP | 1029.00 | 58.00 | 365 |
2012 | S & S ENERGY CORP | 853.00 | 0.00 | 366 |
2013 | S & S ENERGY CORP | 870.00 | 34.00 | 365 |
2014 | S & S ENERGY CORP | 636.00 | 0.00 | 365 |
2015 | S & S ENERGY CORP | 114.00 | 0.00 | 30 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1990 | BELDEN & BLAKE CORPORATION | Brine | 55 | 199 |
1991 | BELDEN & BLAKE CORPORATION | Brine | 40 | 365 |
1992 | BELDEN & BLAKE CORPORATION | Brine | 113 | 341 |
1993 | BELDEN & BLAKE CORPORATION | Brine | 133 | 356 |
1994 | BELDEN & BLAKE CORPORATION | Brine | 53 | 351 |
1995 | BELDEN & BLAKE CORPORATION | Brine | 135 | 352 |
1996 | BELDEN & BLAKE CORPORATION | Brine | 71 | 354 |
1997 | BELDEN & BLAKE CORPORATION | Brine | 46 | 341 |
1998 | BELDEN & BLAKE CORPORATION | Brine | 50 | 322 |
1999 | BELDEN & BLAKE CORPORATION | Brine | 65 | 268 |
2000 | BELDEN & BLAKE CORPORATION | Brine | 22 | 359 |
2001 | BELDEN & BLAKE CORPORATION | Brine | 53 | 359 |
2002 | BELDEN & BLAKE CORPORATION | Brine | 49 | 190 |
2003 | PETROX, INC | Brine | 0 | 365 |
2004 | PETROX, INC | Brine | 72 | 365 |
2005 | PETROX, INC | Brine | 0 | 180 |
2006 | S & S ENERGY CORP | Brine | 84 | 365 |
2007 | S & S ENERGY CORP | Brine | 58 | 365 |
2008 | S & S ENERGY CORP | Brine | 53 | 365 |
2009 | S & S ENERGY CORP | Brine | 97 | 365 |
2010 | S & S ENERGY CORP | Brine | 23 | 365 |
2011 | S & S ENERGY CORP | Brine | 65 | 365 |
2012 | S & S ENERGY CORP | Brine | 41 | 366 |
2013 | S & S ENERGY CORP | Brine | 32 | 365 |
2014 | S & S ENERGY CORP | Brine | 0 | 365 |
2015 | S & S ENERGY CORP | Brine | 0 | 30 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0811647033 | 2015-12-08 | Exempt Well Pre Transfer | No Violations | On the day of my inspection following up on an exempt well pre-transfer inspection accompanying ODNR Inspector Joe Zollars, I witnessed the production equipment included a 210bbl tank, a horizontal separator, a drip, a 2 inch sales meter with a.75 inch orifice and a chart recorder all within an earthen dike. The well was equipped with 8.625 inch casing, 4.5 inch casing, 1.5 inch tubing, a plunger lift system and domestic gas service with valves closed on the tubing and 1 of 2 valves in the open position on the casing supplying the domestic gas. A 1 inch domestic gas line went from the well to a drip and into the residence of Kay McMillen at 84140 Plum Run Road Tippecannoe, OH 44699. Identification was present and production records were current. |
1449592035 | 2015-12-08 | Exempt Well Pre Transfer | No Violations | Inspector Bennett and I are conducting an exempt well pre transfer site inspection for the Columbus office requested by Kathryn Smith. I started my inspection with a check of the production records for 2014 and found that the well was producing commercial volumes of gas. During my review of the production facility I found a 210 bbl. tank with proper identification, and a horizontal separator. The tank and separator were placed inside a dike that will be able to hold the contents of the production tank. The well was run by a Plunger Lift system, which consisted of 8 5/8 inch diameter surface casing, 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. A regulator and a house meter were tied into the backside of the production tubing. The house meter was in working order and showed signs of use. From the meter there was a 1 inch gas line that ran into a drip then into the house. There were no compliance issues at the date of this inspection. I then met with the landowner Kay McMillen. Kay confirmed that she was using the gas from the well to heat her house and planned to continue using the gas in the future. I asked Kay if she had purchased the well, she advised me that she had signed the papers to purchase the well but the final transaction was still pending. |
1653764013 | 2015-11-10 | Exempt Well Pre Transfer | No Violations | I am conducting a pre transfer site inspection for the Columbus office requested by Kathryn Smith. I started my inspection with a check of the production records for 2014 and found that the well was producing commercial volumes of gas. During my review of the production facility I found a 210 bbl tank with proper identification, and a horizontal separator. The tank and separator were placed inside a dike that will be able to hold the contents of the production tank. The well was ran by a Plunger Lift system, which consisted of 8 5/8 inch diameter surface casing, 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubing. A regulator and a house meter were tied into the backside of the production tubing. The house meter was in working order and showed signs of use. There were no compliance issues at the date of this inspection. I then met with the landowner Kay McMillen. Kay confirmed that she was using the gas from the well to heat her house and planned to continue using the gas in the future. I asked Kay if she had purchased the well, she advised me that she had signed the papers to purchase the well but the final transaction was pending. |
811647033 | 2015-12-8 0:00: | EX | No Violations | 2.00 |
For data sources see[9]