Well Details

Well ID: 34-059-24526
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Londonderry Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-000908
Farm/Lease Name: RED HILL FARM SE MDS GR
License Status: Producing
License Date: 2018-05-25
Spud Date: 2018-06-27
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2018-10-04
Well Total Depth: 20883.00 ft
Configuration: Horizontal
Latitude: 40.120000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2018-05-25 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:5/25/2018, Expired Date:5/24/2020 12:00:00 PM, Drilling unit acres:708.437, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2018-10-04
Correction to Well 2018-12-21 UPDATE TAKE/TARGET PER AS-DRILLED PLAT.
Record Last Modified 2019-06-11
Construction Permit Expires 2020-05-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
20600 20699 0
7920 8051 0
7920 8051 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/27/2018 12/19/2018 7450 18,240,900.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 HCL Acid (7.5%) UPP Acidizing Hydrochloric Acid 7647-01-0 7.5 0.0958356 168284
Water Ascent Carrier/Base Fluid Water 7732-18-5 100 86.6876 152,221,000.0
FR-11 UPP Friction reducer CHEMPLEX-Polymer_00019 Trade Secret 25 0.0138447 24310.9
Ammonium Chloride 12125-02-9 2 0.00110758 1944.87
Alcohol Ethoxylate Surfactants 68551-12-2 3 0.00166137 2917.3
Hydrotreated Petroleum Distillate 64742-47-8 25 0.0138447 24310.9
Water 7732-18-5 55 0.0304584 53483.9
Polyoxyethylene Sorbitan Monoleate 9005-65-6 1 0.000553789 972.435
Oleic Acid Diethanolamide 93-83-4 3 0.00166137 2917.3
Sodium Chloride 7647-14-5 15 0.00830683 14586.5
K-Bac 1005 UPP Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 5.8 0.000799146 1403.27
Polyethylene glycol 7732-18-5 50 0.00693703 12181.2
Water 7732-18-5 44.3 0.00614621 10792.5
Scale Hib PE-18 UPP Scale Inhibitor Ethylene glycol 107-21-1 40 0.00992306 17424.6
Proprietary Scale Inhibitor Proprietary 30 0.00744229 13068.4
Unihib G UPP Acid inhibitor Formaldehyde 50-00-0 1 0.00000994 17.462
Thiourea 62-56-6 1 0.00000994 17.462
Methanol 67-56-1 5 0.00004972 87.31
Butyl diglycol 112-34-5 75 0.000745825 1309.64
Alcohols, C10-16, ethoxylated 68002-97-1 50 0.000497216 873.096
Other Chemical(s) Listed Above See Trade Name(s) List Methanol 67-56-1 5 0.00004972 87.31
Ethylene glycol 107-21-1 20 0.00133298 2340.67
Polyethylene glycol 7732-18-5 50 0.00693703 12181.2
Ammonium Chloride 12125-02-9 2 0.00110758 1944.87
Hydrotreated Petroleum Distillate 64742-47-8 25 0.0138447 24310.9
Oleic Acid Diethanolamide 93-83-4 3 0.00166137 2917.3
Thiourea 62-56-6 1 0.00000994 17.462
Water 7732-18-5 44.3 0.00614621 10792.5
Polyoxyethylene Sorbitan Monoleate 9005-65-6 1 0.000553789 972.435
Sodium Chloride 7647-14-5 15 0.00830683 14586.5
Ethylene glycol 107-21-1 40 0.00992306 17424.6
Alcohol Ethoxylate Surfactants 68551-12-2 3 0.00166137 2917.3
Alcohols, C10-16, ethoxylated 68002-97-1 50 0.000497216 873.096
Formaldehyde 50-00-0 1 0.00000994 17.462
Water 7732-18-5 55 0.0304584 53483.9
Hydroxyacetic acid 79-14-1 5 0.000333245 585.168
I-7L UPP Iron Control Ammonium glycolate 35249-89-9 20 0.00133298 2340.67
Hydroxyacetic acid 79-14-1 5 0.000333245 585.168
Ethylene glycol 107-21-1 20 0.00133298 2340.67
Sand UPP Proppant Crystalline Silica in the form of Quartz 14808-60-7 99.9 11.9209 20,932,700.0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2019 ASCENT RESOURCES UTICA LLC 82102 27327 39

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2019 ASCENT RESOURCES UTICA LLC Brine 3938 39

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1068953618 2019-12-12 0:00 PW No Violations 0.20
-1611361793 2019-1-18 0:00: CT No Violations 0.30
-1639159662 2020-6-22 0:00: PW No Violations
-355349966 2019-1-14 0:00: CT No Violations 0.50
-592690692 2019-3-18 0:00: PW No Violations 0.20
0355349966 2019-01-14 Completion Testing No Violations On the day of my inspection I talked to company man Chuck Davies on the progress of the work. The well has had frac plugs drilled out and is waiting on placing in production.
0522478711 2018-12-28 Preliminary Restoration No Violations The purpose of my inspection was a status check on a preliminary restoration. There were a total of 7 wells on pad, three remain temporarily abandoned, and four had just completed hydraulic stimulation operations and are awaiting drill-out and flow back operations. Frac equipment was demobilizing off pad. The location meets the requirements for preliminary restorations within the Ohio Revised Code 1509.072 (A).
0582621975 2018-06-28 Casing String Witnessed No Violations The inspection was conducted as casing string inspection. The temperature is 82 degrees Fahrenheit. Ascent is setting 30-inch conductor pipe in 36-inch open hole. The tin horn measures 10 foot across and 13 feet deep. The 30-inch conductor inside diameter is 29.25 inch and weighs 118.76 lbs. /ft. The rig ran the conductor pipe to 100-foot-deep and had a shoe of 10 foot on the bottom. O-tex cementing services had mixed 67.3 barrels of slurry and displaced down with 75 barrels of fresh water. The slurry was mixed with 50 percent excess. There was good circulation with 10 barrels of slurry returns.
0592690692 2019-03-18 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with open valves. Gauges present read 0 pounds per square inch on the 13.375-inch diameter surface casing, 0 pounds per square inch on the 9.625-inch diameter intermediate casing, 3000 pounds per square inch on the 5.5-inch diameter production casing, 1100 pounds per square inch on the production tubing. The production equipment on location consisted on seven sand traps, seven gas production units, three horizontal heater treaters, four compressors, six 400-barrel tanks, five 500-barrel tanks, two vapor recovery towers, and one combustor.
0912294923 2018-09-25 Drill / Deepen / Reopen No Violations The purpose of my inspection was a status check on drilling operations. Accompanied by ODNR Kenn Frye, during our inspection we completed a walk around with Ascent Resources Superintendent James McGee. Patterson 577 was tripping out of hole to pick up the lateral assembly after landing the curve and drilling to a depth of 8110 feet. The kick off point was at 6742 feet. The anti-collision plan was evaluated.
0988135568 2018-10-11 Drill / Deepen / Reopen No Violations During my inspection Patterson 577 was no longer on location, drilling operations have been completed, and the well was awaiting to be completed.
1537352317 2018-09-19 Casing String Witnessed No Violations 13.35-inch diameter surface casing was ran to 1225 feet within the 17.5 inch diameter borehole. During my inspection I witnessed C&J Services O-Tex Cementing rig up on location. A safety meeting was held with all personnel on location. Following the safety meeting O-Tex pumped 50 barrels of gel, 10 barrels of fresh water, 1265 sacks (271 barrels) of class A cement, and 180 barrels for displacement. The cement was weighed in pressurized mud scales confirming the weight of 15.6 pounds per gallon. Cement returns were established.
1611361793 2019-01-18 Completion Testing No Violations The purpose of my inspection was a status check on drilling out frac plugs. During my inspection Fortis Energy Services had a derrick service rig on location. Frac plugs have been drilled out and 6.5 pound per foot 2.875-inch diameter production tubing had been installed.
1859343008 2019-02-21 Production Wells No Violations The purpose of my inspection was a status check on flow back operations. During my inspection the well was equipped with a production tree style wellhead with open valves. The flow back equipment on location consisted of three gas buster tanks, one frac tank, and three horizontal line heaters. The production equipment on location consisted on seven sand traps, seven gas production units, three horizontal heater treaters, four compressors, six 400-barrel tanks, five 500-barrel tanks, two vapor recovery towers, and one combustor.
522478711 2018-12-28 0:00 PL No Violations 0.10
582621975 2018-6-28 0:00: CS No Violations 1.00
912294923 2018-9-25 0:00: DD No Violations 1.00
988135568 2018-10-11 0:00 DD No Violations 0.20

For data sources see[9]