X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24524

Well Details

Well ID: 34-059-24524
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Londonderry Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-000908
Farm/Lease Name: RED HILL FARM SW MDS GR
License Status: Producing
License Date: 2018-05-25
Spud Date: 2018-08-02
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2018-08-16
Well Total Depth: 21301.00 ft
Configuration: Horizontal
Latitude: 40.120000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2018-05-25 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:5/25/2018, Expired Date:5/24/2020 12:00:00 PM, Drilling unit acres:259.606, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2018-08-16
Correction to Well 2018-12-21 UPDATE TAKE/TARGET PER AS-DRILLED PLAT
Record Last Modified 2019-06-11
Construction Permit Expires 2020-05-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
21067 21117 0
7973 7821 0
7973 7821 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/04/2018 11/25/2018 7428 15,798,700.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Scale Hib PE-18 UPP Scale Inhibitor Ethylene glycol 107-21-1 40 0.00998071 15095.7
Proprietary Scale Inhibitor Proprietary 30 0.00748553 11321.8
HCL Acid (7.5%) UPP Acidizing Hydrochloric Acid 7647-01-0 7.5 0.107379 162409
I-7L UPP Iron Control Hydroxyacetic acid 79-14-1 5 0.000373208 564.472
Ethylene glycol 107-21-1 20 0.00149283 2257.89
Ammonium glycolate 35249-89-9 20 0.00149283 2257.89
Other Chemical(s) Listed Above See Trade Name(s) List Oleic Acid Diethanolamide 93-83-4 3 0.00166447 2517.49
Ammonium Chloride 12125-02-9 2 0.00110964 1678.32
Ethylene glycol 107-21-1 20 0.00149283 2257.89
Ethylene glycol 107-21-1 40 0.00998071 15095.7
Water 7732-18-5 44.3 0.00769754 11642.4
Hydroxyacetic acid 79-14-1 5 0.000373208 564.472
Thiourea 62-56-6 1 0.00001124 16.996
Polyethylene glycol 7732-18-5 50 0.00868797 13140.5
Alcohols, C10-16, ethoxylated 68002-97-1 50 0.000561864 849.813
Polyoxyethylene Sorbitan Monoleate 9005-65-6 1 0.000554822 839.162
Water 7732-18-5 55 0.0305152 46153.9
Methanol 67-56-1 5 0.00005619 84.981
Formaldehyde 50-00-0 1 0.00001124 16.996
Alcohol Ethoxylate Surfactants 68551-12-2 3 0.00166447 2517.49
Hydrotreated Petroleum Distillate 64742-47-8 25 0.0138705 20979
Sodium Chloride 7647-14-5 15 0.00832233 12587.4
Unihib G UPP Acid inhibitor Thiourea 62-56-6 1 0.00001124 16.996
Methanol 67-56-1 5 0.00005619 84.981
Formaldehyde 50-00-0 1 0.00001124 16.996
Butyl diglycol 112-34-5 75 0.000842796 1274.72
Alcohols, C10-16, ethoxylated 68002-97-1 50 0.000561864 849.813
K-Bac 1005 UPP Biocide Water 7732-18-5 44.3 0.00769754 11642.4
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 5.8 0.00100085 1513.78
Polyethylene glycol 7732-18-5 50 0.00868797 13140.5
Water Ascent Carrier/Base Fluid Water 7732-18-5 100 87.1678 131,840,000.0
Sand UPP Proppant Crystalline Silica in the form of Quartz 14808-60-7 99.9 11.2828 17,065,100.0
FR-11 UPP Friction reducer Alcohol Ethoxylate Surfactants 68551-12-2 3 0.00166447 2517.49
Sodium Chloride 7647-14-5 15 0.00832233 12587.4
Polyoxyethylene Sorbitan Monoleate 9005-65-6 1 0.000554822 839.162
Hydrotreated Petroleum Distillate 64742-47-8 25 0.0138705 20979
Oleic Acid Diethanolamide 93-83-4 3 0.00166447 2517.49
CHEMPLEX-Polymer_00019 Trade Secret 25 0.0138705 20979
Water 7732-18-5 55 0.0305152 46153.9
Ammonium Chloride 12125-02-9 2 0.00110964 1678.32

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2019 ASCENT RESOURCES UTICA LLC 94281 30233 41

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2019 ASCENT RESOURCES UTICA LLC Brine 2376 41

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1614300254 2019-2-21 0:00: PW No Violations 0.30
-1864095487 2018-6-26 0:00: CS No Violations 2.80
-1868832098 2019-3-18 0:00: PW No Violations 0.20
-2111231135 2018-12-28 0:00 PL No Violations 0.10
-282836048 2019-1-14 0:00: CT No Violations 0.20
-408057584 2020-6-22 0:00: PW No Violations 1.00
0022862142 2018-10-11 Drill / Deepen / Reopen No Violations During my inspection Patterson 577 was no longer on location, drilling operations have been completed, and the well was awaiting to be completed.
0282836048 2019-01-14 Completion Testing No Violations On the day of my inspection I spoke with Ascent company man Chuck Davies on the well progress. The Fortis service rig will move to this well and drill out the frac plugs.
0908336510 2018-08-13 Drill / Deepen / Reopen No Violations During my inspection Patterson 577 was drilling at 16414 feet within the 8.5-inch diameter lateral production borehole. Ascent plans to reach a total depth by Wednesday 8/15/18. The 5.5-inch diameter production casing was arriving on location and being installed on the pipe racks.
1527477873 2018-08-02 Drill / Deepen / Reopen No Violations Patterson Drilling Rig 577 was rigged up on location. During my inspection the drill string with bottom hole assembly and 17.5-inch diameter bit was hanging in hole at 115 feet. The rig was preparing to dill out the shoe of the 30-inch conductor casing. I spoke with Ascent Company man on location and he stated that they will spud once the rig has completed the necessary corrections to the flow line.
1547821261 2019-01-18 Completion Testing No Violations The purpose of my inspection was a status check on drilling out frac plugs. During my inspection Fortis Energy Services had a derrick service rig on location. The rig was in the process of moving to the well to drill out 78 frac plugs and install 2.875-inch diameter production tubing.
1614300254 2019-02-21 Production Wells No Violations The purpose of my inspection was a status check on flow back operations. During my inspection the well was equipped with a production tree style wellhead with open valves. The flow back equipment on location consisted of three gas buster tanks, one frac tank, and three horizontal line heaters. The production equipment on location consisted on seven sand traps, seven gas production units, three horizontal heater treaters, four compressors, six 400-barrel tanks, five 500-barrel tanks, two vapor recovery towers, and one combustor.
1864095487 2018-06-26 Casing String Witnessed No Violations The inspection was conducted under dry with upcoming rain and thunderstorms. The temperature is 82 degrees Fahrenheit. Ascent is setting 30-inch conductor pipe in 36-inch open hole. The tin horn measures 10 foot across and 13 feet deep. The 30-inch conductor inside diameter is 29.25 inch and weighs 118.76 lbs. /ft. The rig ran the conductor pipe to 100-foot-deep and had a shoe of 10 foot on the bottom. O-tex cementing services had mixed 67.3 barrels of slurry and displaced down with 75 barrels of fresh water. The slurry was mixed with 50 percent excess. There was good circulation with 7 barrels of slurry returns.
1868832098 2019-03-18 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with open valves. Gauges present read 0 pounds per square inch on the 13.375-inch diameter surface casing, 0 pounds per square inch on the 9.625-inch diameter intermediate casing, 3000 pounds per square inch on the 5.5-inch diameter production casing, 2800 pounds per square inch on the production tubing. The production equipment on location consisted on seven sand traps, seven gas production units, three horizontal heater treaters, four compressors, six 400-barrel tanks, five 500-barrel tanks, two vapor recovery towers, and one combustor.
2111231135 2018-12-28 Preliminary Restoration No Violations The purpose of my inspection was a status check on a preliminary restoration. There were a total of 7 wells on pad, three remain temporarily abandoned, and four had just completed hydraulic stimulation operations and are awaiting drill-out and flow back operations. Frac equipment was demobilizing off pad. The location meets the requirements for preliminary restorations within the Ohio Revised Code 1509.072 (A).
22862142 2018-10-11 0:00 DD No Violations 0.10
297108416 2019-12-12 0:00 PW No Violations 0.20
908336510 2018-8-13 0:00: DD No Violations 1.00

For data sources see[9]

References