{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.02,"lon":-81.44,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Wills Township | |
Operator Name: CLEARWATER FIVE LLC | |
Well Pad ID: | |
Farm/Lease Name: SHIELDS ONE (SWIW #17) | |
License Status: Active Injection | |
License Date: 2014-11-19 | |
Spud Date: 2015-09-10 | |
Spud Drilling Contractor: | |
Final Drill Date: 2015-10-16 | |
Well Total Depth: 9097.00 ft | |
Configuration: Vertical | |
Latitude: 40.020000 | |
Longitude: -81.440000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-11-25 | Proposed Formations:KNOX THRU MT SIMON, Issued Date:11/25/2014, Expired Date:11/24/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Last Compliance Report | 2015-06-24 | |
Reached Total Depth | 2015-10-16 | |
Completion Report Received | 2015-12-16 | |
Correction to Well | 2016-02-26 | CHANGE IN LEASE NAME. |
Construction Permit Expires | 2016-11-18 | |
Record Last Modified | 2017-10-23 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2017-04-05 | 7930 | 9097 | 0 |
7930 | 9097 | 0 | |
7930 | 9097 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1012538764 | 2019-8-20 0:00: | SW | No Violations | |
-1030909473 | 2017-2-7 0:00:0 | SW | No Violations | |
-1072987519 | 2017-3-15 0:00: | SW | No Violations | |
-112930213 | 2018-11-14 0:00 | SW | No Violations | |
-1149635378 | 2018-11-5 0:00: | SW | No Violations | |
-1151732724 | 2018-2-12 0:00: | SW | No Violations | |
-1164288683 | 2017-7-13 0:00: | SW | No Violations | |
-1242269804 | 2016-10-18 0:00 | SW | No Violations | |
-1244218368 | 2018-11-15 0:00 | SW | No Violations | 8.00 |
-1251588339 | 2016-2-23 0:00: | SW | No Violations | |
-1253655999 | 2017-3-22 0:00: | SW | No Violations | |
-1395085306 | 2017-5-23 0:00: | SW | No Violations | |
-1492446639 | 2016-3-7 0:00:0 | SW | No Violations | |
-1496219212 | 2018-1-19 0:00: | SW | No Violations | |
-1496457786 | 2019-11-22 0:00 | CT | No Violations | 2.00 |
-1576149376 | 2017-4-8 0:00:0 | SW | No Violations | |
-1634153 | 2017-3-16 0:00: | SW | No Violations | |
-1810463818 | 2015-12-2 0:00: | SW | No Violations | |
-1832568815 | 2015-9-10 0:00: | SW | No Violations | |
-1884702357 | 2015-9-18 0:00: | SW | No Violations | |
-1885312281 | 2017-5-30 0:00: | SW | No Violations | |
-1893250358 | 2016-7-21 0:00: | SW | No Violations | |
-2013758899 | 2015-9-14 0:00: | CS | No Violations | |
-2020346264 | 2017-2-28 0:00: | SW | No Violations | |
-2026399659 | 2018-5-7 0:00:0 | SW | No Violations | |
-2031462904 | 2017-3-9 0:00:0 | SW | No Violations | |
-2049691769 | 2018-4-15 0:00: | SW | No Violations | |
-2054487213 | 2018-11-29 0:00 | SW | No Violations | |
-2058264238 | 2018-1-2 0:00:0 | SW | No Violations | |
-2101955024 | 2017-3-21 0:00: | SW | No Violations | |
-234210672 | 2018-10-1 0:00: | SW | No Violations | |
-253779469 | 2017-8-28 0:00: | PL | No Violations | |
-346525157 | 2015-10-15 0:00 | SW | No Violations | |
-353838879 | 2015-9-11 0:00: | SW | No Violations | |
-377682197 | 2015-10-18 0:00 | SW | No Violations | 6.00 |
-37873640 | 2019-7-29 0:00: | SW | No Violations | |
-414375328 | 2020-8-20 0:00: | SW | No Violations | |
-465023735 | 2018-4-22 0:00: | SW | No Violations | |
-481147394 | 2015-8-24 0:00: | DD | No Violations | |
-55828603 | 2017-3-27 0:00: | SW | No Violations | |
-634310545 | 2016-8-30 0:00: | SW | No Violations | |
-665439630 | 2015-12-17 0:00 | SW | No Violations | |
-665517496 | 2018-5-31 0:00: | SW | No Violations | |
-676297616 | 2017-2-22 0:00: | SW | No Violations | |
-695410048 | 2018-3-30 0:00: | SW | No Violations | |
-705624007 | 2019-3-6 0:00:0 | SW | No Violations | |
-782689501 | 2017-7-20 0:00: | SW | No Violations | |
-787972977 | 2017-4-12 0:00: | SW | No Violations | |
-886158026 | 2018-2-15 0:00: | SW | No Violations | |
-887078885 | 2017-3-29 0:00: | SW | No Violations | |
-91856545 | 2018-11-2 0:00: | SW | No Violations | |
-93617984 | 2018-7-27 0:00: | SW | No Violations | |
-950031445 | 2018-5-25 0:00: | SW | No Violations | |
-97472692 | 2017-3-23 0:00: | SW | No Violations | |
0001634153 | 2017-03-16 | Salt Water Injection Well | No Violations | On site to attempt to kill well before pulling packer assembly Formation Cementings pump truck arrived on site and hooked up to frac tank filled with 10.5# brine and they pumped tubing capacity which was 123 bbl. And then they hooked to annular side of well and tried to pump annular volume but after two bbl it pressured up so decision was made to continue to pump down tubing to make well become static and after 300 bbl well went on vacuum they checked annulus and it was also static so decision was made to pull packer assembly. |
0055828603 | 2017-03-27 | Salt Water Injection Well | No Violations | Inspection revealed that casing was cut off at 4062 and removed from well and patch installed and casing was reattached with existing casing and pipe was filled and pressure tested. |
0091856545 | 2018-11-02 | Salt Water Injection Well | No Violations | Inspection revealed that Excel Services was on site preparing to rig up and attempt to repair well, containment was put in place and equipment spotted and pre workover meeting held. |
0093617984 | 2018-07-27 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today.
Note: Housekeeping needed in containment area. |
0097472692 | 2017-03-23 | Salt Water Injection Well | No Violations | Baker Hughes wireline truck on site running tools in hole to pinpoint hole in casing it was located at 3980 in a collar and company reps are currently reviewing data to come up with a plan to repair casing. |
0112930213 | 2018-11-14 | Salt Water Injection Well | No Violations | On site today to witness Appalachian Well Surveys run bond log over area of casing that they recently cemented to ensure that they had good cement above and below perforated intervals in casing.
|
0134605706 | 2017-05-18 | Salt Water Injection Well | No Violations | Inspection today revealed that two injection pumps were in operation during my inspection and it was noted that the third pump was down for electrical problems. |
0166093742 | 2017-06-30 | Salt Water Injection Well | No Violations | On site to witness Producers Services pump 2500 gallon of 28% acid treatment on said well ISIP was noted at 1115 psi and Clearwater displaced acid to injection zone. |
0169591902 | 2016-06-07 | Salt Water Injection Well | No Violations | Inspection today revealed that pump house is still under construction and it was noted that presently there is twelve 5000 bbl.. Tanks placed within containment area. |
0180313032 | 2017-06-07 | Salt Water Injection Well | No Violations | I received a call from Ohio Environmental Protection Agency (OEPA) Environmental Specialist II Nick Hammer concerning a complaint he received regarding water being released from a tank at the Clearwater Facility on State Route 285. Upon arrival I met with Brine Technician John Fleece who guided me on a tour of the facility and when questioned about any releases at the facility Mr. Fleece stated that at approximately 1600 on 6/6/17 one of the two rubber boots failed on the containment sump pump line resulting in water to be pumped through the discharge line into the air and back into the containment cycling until it was found. The sump discharge line was repaired and nothing released outside containment. |
0234210672 | 2018-10-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection. |
0243758115 | 2017-08-07 | Salt Water Injection Well | No Violations | Confirming GPS reading on well head.
Injection pumps were in operation. |
0253779469 | 2017-08-28 | Preliminary Restoration | No Violations | Restoration work at site is satisfactory pits have been closed in and site restored.
Note : Producers Services on site performing 2500 gallon acid treatment on said well. |
0315599471 | 2017-09-29 | Salt Water Injection Well | No Violations | Inspection today indicated that Producers Services was on site to perform 5000 gallon acid treatment on said well and then perform 1500 bbl frack job on same. |
0325150507 | 2018-07-17 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pumps were not in operation and it was noted that desander was under repair and well attendant stated that parts were ordered and they expected to be back in operation on Thursday. |
0336332098 | 2017-01-31 | Surface Facility Construction | No Violations | Inspection today revealed that splash wall has been constructed in area of unloading pad near there offloading line to help prevent any spillage from contaminating any soils near pad.
Note wall is 45 tall and approximately 15 long it should keep water from unloading process on the unloading pad. |
0346525157 | 2015-10-15 | Salt Water Injection Well | No Violations | Falcon rig 39 drilling on fluid at 9033 at the time of my inspection. |
0353838879 | 2015-09-11 | Salt Water Injection Well | No Violations | Falcon drilling rig 39 on site and they are at 20deep with 28 hole and they are planning on cementing operational pipe in place later today. |
0377682197 | 2015-10-18 | Salt Water Injection Well | No Violations | On site to witness cementing of 7 casing details on prior report. |
0465023735 | 2018-04-22 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were in operation during my inspection and they were receiving water from Mud Masters during my inspection. |
0481147394 | 2015-08-24 | Drill / Deepen / Reopen | No Violations | Falcon rig#39 on site waiting on proposed start up date of 9/10/15. |
0488106109 | 2017-06-15 | Salt Water Injection Well | No Violations | Inspection today revealed that Producers Services was on site to perform 2000 gallon acid treatment on said well. |
0508507930 | 2017-01-26 | Salt Water Injection Well | No Violations | Inspection today revealed that owner is waiting on Chiefs Order to authorize them to inject brine into well, checked storage tanks at site to confirm they were empty and they were as of this date. |
0530373978 | 2018-10-29 | Salt Water Injection Well | No Violations | On site with Allen Goodrich to attempt to pressure test annulus of tubing this is the third attempt to pressure test, well has been down since pressure issue was detected last week they just wanted to make one last effort to confirm that production casing has integrity issue. |
0535107156 | 2019-04-17 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection.
Note: Noticed that high pressure injection line hose was showing signs of fatique,made operator aware of my concerns and he stated that they would replace line within the next couple days. |
0567201187 | 2016-07-11 | Salt Water Injection Well | No Violations | On site to witness pressure testing of 10 supply line to pump house they applied 75 psi to line and we monitored it for 30 minutes with no decline in pressure and we also pressured up on outer pipe to ensure that it held good pressure. |
0569747538 | 2018-10-02 | Salt Water Injection Well | No Violations | Producers Services on site to perform 2500 gallon acid treatment on said well.
28%HCL was used for treatment. |
0573418821 | 2016-05-27 | Salt Water Injection Well | No Violations | Inspection today revealed that owner was having storage tanks delivered to site and placed within containment area.
Note: Told Tom Meinhart that a current MIT test would be required once facility is constructed and ready to go into operation. |
0600025799 | 2016-03-18 | Salt Water Injection Well | No Violations | Pump house still under construction but there was no activity at the site today. |
0634310545 | 2016-08-30 | Salt Water Injection Well | No Violations | Facility still under construction. |
0635280793 | 2019-02-20 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pumps were in operation during my inspection, and it was noted that four Buckeye Water Services vacuum trucks were on site offloading during my inspection. |
0650243283 | 2017-03-13 | Salt Water Injection Well | No Violations | Halliburton tech on site to attempt to release packer Mountain States service rig is rigged up oner hole with sphere in the 4.5 injection string trying to get it pulled up to remove slips from casing string,worked on freeing them up all day will go to plan B tomorrow. |
0653376678 | 2016-11-08 | Salt Water Injection Well | No Violations | Stopped by site and confirmed dike height and looked over area where newly placed concrete had been poured in the area of the proposed truck offloading area. |
0665439630 | 2015-12-17 | Salt Water Injection Well | No Violations | No activity at the site today but since my last inspection there has been four tanks placed into containment area. |
0665517496 | 2018-05-31 | Salt Water Injection Well | No Violations | Inspecting today indicated that injection pumps were not in operation during my inspection and it was noted that three Ryan Environmental vacuum trucks were on site during my inspection. |
0676297616 | 2017-02-22 | Salt Water Injection Well | No Violations | Well currently not in operation owner is waiting on Chiefs Order to Inject to be issued. |
0695410048 | 2018-03-30 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were in operation during my inspection.
|
0702537347 | 2016-11-30 | Salt Water Injection Well | No Violations | Inspection today indicated that contractor is placing more concrete in driveway area and the extension on dike height area is still in need of proper sealant and according to company rep they should be ready to test injection line going to wellhead next week. |
0705624007 | 2019-03-06 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
|
0758391317 | 2018-05-18 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during our inspection.
|
0782633312 | 2019-02-11 | Salt Water Injection Well | No Violations | Inspection revealed that one injection pump was in operation during my inspection and it was noted that electrical contractor was on site repairing transfer pump motor(tank area beside Mud Masters) once replaced they will begin to transfer water to clean water tanks. |
0782689501 | 2017-07-20 | Salt Water Injection Well | No Violations | Inspection today revealed that one injection pump was in operation during my inspection and it was noted that one ECM tanker was unloading at the facility on the day of my inspection. |
0787972977 | 2017-04-12 | Salt Water Injection Well | No Violations | Inspection today indicated that one injection pump was in operation during my inspection and it was noted that cleanup has begun in tank area they had trash and unused building material in this area that I requested that they remove. |
0842509063 | 2018-07-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were in operation during our inspection and we noted that there was no truck traffic at the facility during our inspection. |
0850110889 | 2018-03-04 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation during my inspection.
Told operator that positive pressure needed to be applied to annulus of tubing. |
0886158026 | 2018-02-15 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection and it was noted that six Myers tankers were waiting to offload during my inspection. |
0887078885 | 2017-03-29 | Salt Water Injection Well | No Violations | On site to witness running and testing of 7 lead patch /overshot too repair casing integrity issue.
e Tested integrity of 7 casing@1900 psi with no decline in pressure in one hour test period. |
0890886894 | 2015-10-26 | Salt Water Injection Well | No Violations | Owner preparing site for service rig to move in on site, the rig should be here in the morning and we will bond log well in the afternoon. |
0950031445 | 2018-05-25 | Salt Water Injection Well | No Violations | Inspection today indicated that two injection pumps were in operation during my inspection.
Site supervisor and well attendant were power washing inside of pumphouse today. |
0989617082 | 2018-01-30 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection. |
1025323809 | 2018-04-19 | Salt Water Injection Well | No Violations | Inspected site today along with two engineers from central office to explain the workings of a Salt Water Injection Well. |
1026715905 | 2018-01-19 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were in operation during my inspection.
|
1030909473 | 2017-02-07 | Salt Water Injection Well | No Violations | Inspection today revealed that pumphouse construction is complete and owner is currently waiting on Chiefs Order to Inject Brine into well. |
1036803984 | 2020-6-18 0:00: | SW | No Violations | |
1041702698 | 2016-09-21 | Salt Water Injection Well | No Violations | Facility still under construction. |
1053186689 | 2015-10-27 | Salt Water Injection Well | No Violations | On site to witness Appalachian Well Surveys bond log well they logged from 7874 to 4300 and it was determined that cement top was at 4715 well above the Lockport section of the well bore. |
1072987519 | 2017-03-15 | Salt Water Injection Well | No Violations | Moved packer up hole and attempted to reset and test Halliburton tech unable to get packer to set so decision was made to kill well and remove tubing string and packer from wellbore. |
1092215094 | 2019-01-28 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were not in operation during my inspection, noted one Premier vacuum truck was on site during my inspection. |
1094948652 | 2016-11-21 | Salt Water Injection Well | No Violations | Inspection revealed that facility is still under construction and it was noted that owner has raised containment height but failed to have sealant spayed on to prevent leakage in the event of tank failure in tank area next to pump house. |
1131475407 | 2016-01-19 | Salt Water Injection Well | No Violations | Inspection revealed that there is no activity at the site but it was noted that four 400 bbl. Tanks were placed in containment area since my last inspection. |
1149635378 | 2018-11-05 | Salt Water Injection Well | No Violations | On site today to witness Appalachian Well Surveys set bridge plug in bottom of 7 casing in preparation to perform squeeze job on defected casing above cement top which is 4715 they suspect possible collar leak in casing. |
1151732724 | 2018-02-12 | Salt Water Injection Well | No Violations | Producers Services on site to perform 2000 gallon acid treatment on said well. |
1164150164 | 2018-11-11 | Salt Water Injection Well | No Violations | Went to location to pressure test 7 production casing after it was discovered that they had integrity failure, we tested casing at 2000psi with a 15# pressure loss within the 15 minute test period.(TEST PASSED) |
1164288683 | 2017-07-13 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were in operation during my inspection.
Note: Two ECM tankers were on site unloading during my inspection. |
1217534192 | 2018-12-18 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pumps were in operation and it was noted that six Ryan Environmental vacuum trucks were on site waiting to offload during my inspection. |
1242269804 | 2016-10-18 | Salt Water Injection Well | No Violations | Inspection today revealed that work still continues on pump house and it was noted that electrical work was being done on the day of my inspection.
Note: Small containment has been constructed at pump house since my last inspection. |
1244218368 | 2018-11-15 | Salt Water Injection Well | No Violations | On site to witness remaining 4.5 injection string run into well,setting depth of 7868 with a 10 pup joit below packer total assembly was noted at 7879,started to flush brine from well and replace with fresh water and inhibitor it became too late in the day to attempt to set packer and build production tree. |
1251588339 | 2016-02-23 | Salt Water Injection Well | No Violations | Inspection today revealed that well has been completed and owner is planning on starting construction of pumphouse the first week of March 2016.
|
1253655999 | 2017-03-22 | Salt Water Injection Well | No Violations | Suspected hole in casing located at approximatly@3980 and owner is going to have wireline logs run to help determine what steps are needed to come up with repair plan on repairing leak in 7 production casing. |
1257833247 | 2018-08-31 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were in operation during my inspection.
Note: Facility extremely busy today. |
1317401839 | 2017-08-22 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pumps were down and being repaired and there was no trucks unloading at the facility during my inspection. |
1319460375 | 2018-06-06 | Salt Water Injection Well | No Violations | No activity at the site today, injection pump was in operation. |
1336199376 | 2018-11-09 | Salt Water Injection Well | No Violations | Stopped by service rig for update they were drilling cement retainer and cement during my time on site and they plan on drilling below perforations and then well pressure test casing and remedial cement integrity. |
134605706 | 2017-5-18 0:00: | SW | No Violations | |
1395085306 | 2017-05-23 | Salt Water Injection Well | No Violations | On site to witness Producers Services perform 2000 gallon of 28% acid treatment on said well. |
1444057290 | 2015-09-28 | Drill / Deepen / Reopen | No Violations | Inspection revealed that Falcon Rig 39 was tripping bit during my time at the rig. |
1445514962 | 2015-10-17 | Salt Water Injection Well | No Violations | On site to witness 7casing and Weatherford packer start in hole, they ran 7930 of casing and 40 centralizers and Allied cemented with 250 sacks of Class A cement and 350 sacks of 50/50 Poz mix with a estimated cement top at 4800,
Note: Will confirm cement top with bond log at later date. |
1446911830 | 2015-11-07 | Salt Water Injection Well | No Violations | On site to witness packer and tubing run into well.
Note: Job cancelled for today due to Halliburton not having all of the correct change over subs needed to start packer in well. |
1447111382 | 2015-11-08 | Salt Water Injection Well | No Violations | On site to witness tubing and packer run in well, Packer was set@7887 and it was a Halliburton Versa Set and tubing size was 4.5 11.6# per ft. and packer was set in 15 K compression and annulus was tested at 1980 psi with no decline in pressure and Producers Services pumped 160 bbl. And 15 gallon of inhibitor respectively. |
1457382984 | 2016-03-03 | Salt Water Injection Well | No Violations | Inspection today indicated that pumphouse is now under construction.. |
1458430069 | 2016-12-30 | Salt Water Injection Well | No Violations | On site to meet company rep Brad Erdman to discuss getting facility prepped for request of authorization to inject fluid into wellbore. |
1459296505 | 2019-04-04 | Surface Facility Construction | No Violations | Inspection today revealed that injection pump was in operation and one BWS vacuum truck on site during my inspection. |
1462618600 | 2016-05-04 | Salt Water Injection Well | No Violations | Facility still under construction. |
1473352727 | 2016-09-07 | Salt Water Injection Well | No Violations | Inspection today indicated that temporary flow line is in place and we pressure tested it too 300 psi with no decline in pressure this line was put in place as a temporary injection line coming from the Mudd Masters facility, Clearwater has asked for permission to receive water from said facility and they are waiting on approval too do so.
Note: I.D. has been posted at wellhead and they recently performed current MIT on said well and they also installed additional high pressure valve on well head assembly as requested by inspector. |
1479240736 | 2016-11-15 | Salt Water Injection Well | No Violations | Updated containment measurements 48 long and 43.6 wide and 52 high with a calculated volume of 1610 bbl. This area is the one by the pump house. |
1480964318 | 2016-12-05 | Salt Water Injection Well | No Violations | Inspection today revealed that facility is still under construction and I was on site to pressure test injection line and manifold to injection pumps we pressured up to 1900 psi and monitored pressure for 15 minutes on flowline and a additional 15 minutes on manifold with no decline in pressure.
Note: Flowline is 4 steel HD 80 pipe seamless and manifold is the same with a 3 section of 2500 psi high pressure hydraulic hose near wellhead. |
1483045394 | 2016-12-29 | Salt Water Injection Well | No Violations | |
1483555093 | 2017-01-04 | Salt Water Injection Well | No Violations | Inspection today revealed that storage tanks at the facility have been emptied and cleaned and they resealed the unloading trench with spray on liner and in conversation with Brad Erdman stating that grates for unloading pad area will be in place later this week and belt guard for pump number three is being made by local sheet metal company. |
1488902361 | 2017-03-06 | Surface Facility Construction | No Violations | Received call from Brad Erdmam on 3/5/17 that annular pressure has started to rise and I told him to shut well down until we can determine what the problem is I suspect that Halliurton packer started to leak by when they increased injection rate from one pump too two pumps at a rate of four barrel per minute bottom hole pressure was trying to lift tubing and packer string weight allowing it to start leaking,owner is trying to locate proper tools to run wireline plug inside of tubing into packer assembly and pressure test for leakage. |
1488904422 | 2017-03-07 | Salt Water Injection Well | No Violations | Waiting on wireline truck to arrive to set plug in packer and possibly pressure test tubing and packer for integrity. |
1489610316 | 2017-03-10 | Salt Water Injection Well | No Violations | Stopped by site to check on service rig status and check on contractor placing containment under rig and its components theyy were nearly finished with project at the time of my departure from site,will check back on them when they get ready to release packer possibly over the weekeend. |
1489693314 | 2017-03-14 | Salt Water Injection Well | No Violations | Inspection today revealed that well is down for repair and rig crew was attempting to remove slips from wellhead. |
1490647421 | 2017-03-27 | Salt Water Injection Well | No Violations | Inspection today revealed that service company was running casing cutter in well and they plan on cutting casing off at 4062 and remove defected casing and then run enternal lead patch back in well and attach it to casing and then load casing with fresh water and perform pressure test on casing to ensure the division of proper casing integrity. |
1491722006 | 2017-04-07 | Salt Water Injection Well | No Violations | On site to start new injection string into well Weatherford packer and 3.5 tubing ran into well and center of element on packer noted at 7870 and once fresh water arrives we will mix inhibitor and perform MIT testing. |
1491941140 | 2017-04-10 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump number one was in operation during my inspection and I suggested too operator to pick up all unnecessary material within dike area and properly handle used filters ad place them in roll off box. |
1492205843 | 2017-04-14 | Salt Water Injection Well | No Violations | Producers Services on site to perform 3000 gallon acid treatment on said well average pressure during treatmente was noted at 1705 at 4bbl per minute pumping rate and ISIP pressure was noted at 1406 psi and once they went back on line with injection pump pressure was slowly climbing and after thirty minutes is was noted at 1150 psi. |
1492446639 | 2016-03-07 | Salt Water Injection Well | No Violations | Pumphouse is under construction at this time. |
1496219212 | 2018-01-19 | Salt Water Injection Well | No Violations | Restoration work has been completed at this site. |
1498847786 | 2017-06-26 | Salt Water Injection Well | No Violations | Inspection today revealed that two injection pumps were in operation during my inspection. |
1505497688 | 2017-09-14 | Salt Water Injection Well | No Violations | Inspection today indicated that one injection pump was in operation during my inspection and it was noted that two ECM tankers were offloading at the facility today. |
1506717498 | 2017-09-27 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation during my inspection and it was noted that six ECM Tankers were on site during my inspection. |
1507469590 | 2017-09-29 | Salt Water Injection Well | No Violations | Inspection today revealed that Producers Services was on site to perform 5000 gallon acid treatment on said well and then perform pressure treatment on said well. |
1512238168 | 2017-12-01 | Salt Water Injection Well | No Violations | Inspection revealed that two injection pumps were in operation during my inspection.
|
1518208511 | 2018-02-08 | Salt Water Injection Well | No Violations | Inspection today revealed that two injection pumps were in operation during my inspection. |
1521652962 | 2018-03-20 | Salt Water Injection Well | No Violations | Inspection today indicated that only one injection pump was in operation during my inspection and it was noted that service company was replacing pistons on pump number two today. |
1523040386 | 2018-04-05 | Salt Water Injection Well | No Violations | Inspection today revealed that Producers Services was on site to perform 2500 gallon acid treatment on said well. |
1530127627 | 2018-06-26 | Salt Water Injection Well | No Violations | On site today to witness Producers Services perform 2500 gallon acid treatment on said well.
Note: Pressure readings were taken prior to treatment of said well. |
1534186686 | 2018-08-08 | Salt Water Injection Well | No Violations | On site to witness 2500 gallon acid treatment on said well, Producers Services performed treatment and then owner pumped tubing capacity plus 20 barrel extra and then they let acid soak for four hours before putting well back into operation. |
1540583055 | 2018-10-23 | Salt Water Injection Well | No Violations | On site to witness changing of annular valve on wellhead and possibly pressure test annulus of tubing, unable to test today due to time constraint on getting test performed before nightfall. |
1540585091 | 2018-10-24 | Salt Water Injection Well | No Violations | On site today to witness MIT testing of said well after they completed valve change on annulus side of tubing head.
Site personnel applied 1920 psi and pressure declined below maximum allowable tolerance so they reapplied pressure with the same results (TEST FAILED) informed owner to cease injection operations until they could make repairs to production casing. |
1541793166 | 2018-11-08 | Salt Water Injection Well | No Violations | On site this morning to witness cementing of defected 7 casing Halliburton pumped 30 bbl.of gel ahead and mixed 723 sacks of cement at a weight od 14.2# per gallon and displaced through 2.875 tubing which had a cement retainer set at 4170 and perfs were at 4688-4689-10 shots and 4697-4698 -5 shots good circulation through out job and we seen 10 bbl.of the gel back to surface and estimated cement top should be around 600+-.
Excel Services derrick rig performing work on well. Don Krieger company consultant. |
1542665274 | 2018-11-16 | Salt Water Injection Well | No Violations | On site to witness setting and testing of packer and MIT testing,packer@7868 center of element and there is 30K tension pulled on packer. They pressure tested at 1900 psi and they had 15# pressure loss during test period(TEST PASSED). |
1561293419 | 2019-6-20 0:00: | SW | No Violations | |
1574449461 | 2019-11-19 0:00 | SW | No Violations | |
1576149376 | 2017-04-08 | Salt Water Injection Well | No Violations | On site to witness MIT testing they applied 1900 psi to annulus of tubing and we monitored pressure for 15 minutes with no decline in pressure(TEST PASSED). |
1582842857 | 2020-2-26 0:00: | SW | No Violations | |
1586093176 | 2020-3-31 0:00: | SW | No Violations | |
1591377571 | 2020-6-4 0:00:0 | SW | No Violations | |
1593805714 | 2020-7-2 0:00:0 | SW | No Violations | |
1651878749 | 2019-01-18 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection and it was noted that one Heckman Water Resources vacuum truck was on site during my inspection. |
166093742 | 2017-6-30 0:00: | SW | No Violations | |
1670317723 | 2019-9-17 0:00: | SW | No Violations | |
169591902 | 2016-6-7 0:00:0 | SW | No Violations | |
1747676952 | 2017-10-23 | Salt Water Injection Well | No Violations | Inspection today revealed that two injection pumps were in operation during my inspection. |
180313032 | 2017-6-7 0:00:0 | SW | No Violations | 1.00 |
1810463818 | 2015-12-02 | Salt Water Injection Well | No Violations | No activity at the site today owner plans on starting construction of facility in the spring when weather permits good working conditions. |
1811445514 | 2016-04-21 | Salt Water Injection Well | No Violations | Inspection revealed that building of new pump house is still moving forward and I remeasured containment area it is 80.6 wide and 123.2 long and 45 high. |
1832568815 | 2015-09-10 | Salt Water Injection Well | No Violations | Falcon rig#39 on site and they will possibly spud well later today. |
1870317405 | 2018-05-14 | Salt Water Injection Well | No Violations | On site to witness Producers Services perform 2500 gallon 28% acid treatment on said well. |
1884702357 | 2015-09-18 | Salt Water Injection Well | No Violations | Allied cementing topped of surface cement job with additional 100 sacks of Class A cement. |
1885312281 | 2017-05-30 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump to this well was not in operation and it was noted that one Myers tanker was unloading at the facility during my inspection. |
1893250358 | 2016-07-21 | Salt Water Injection Well | No Violations | Inspection revealed that injection pumps were not in operation during my inspection.
Note: Work still continues on permanent facility construction. |
1893983174 | 2016-11-02 | Salt Water Injection Well | No Violations | Inspection today revealed that work still continues at site they were prepping area for the new unloading pad and it was noted that there was a second containment area constructed at site with 5-500 bbl. tanks in it not plumbed up and dike area measurements are as follows48 long and 43.5 wide and 45 tall with a calculated volume of 1394 bbl. capacity. |
1897224743 | 2020-3-12 0:00: | SW | No Violations | |
1902339894 | 2018-09-14 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
Note: Two Ryan Environmental vacuum trucks were offloading at the facility during my inspection. |
1908021344 | 2017-01-11 | Salt Water Injection Well | No Violations | Went by facility and talked to Brad Erdman concerning splash panel that needs to be in place on unloading pad prior to receiving permission to inject brine/oilfield waste into well. |
1951694439 | 2016-08-19 | Salt Water Injection Well | No Violations | On site to witness MIT trsting on said well,Applachian Solvents LLC applied 1900 psi to annulas of tubing and we monitored pressure for 20 minutes with no decline in pressure TEST PASSED. |
2013758899 | 2015-09-14 | Casing String Witnessed | No Violations | Onsite to witness setting and cementing of conductor pipe they set 122 of 20 conductor and Petroset cemented it in place with 250 sacks of Class A cement. |
2020346264 | 2017-02-28 | Salt Water Injection Well | No Violations | Onsite to do final pre-startup inspection of site prior to start up slated for tomorrow morning. |
2026399659 | 2018-05-07 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection. |
2029490597 | 2017-07-26 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pumps were in operation during my inspection.
Note:Three ECM tankers were unloading at the facility during my inspection. |
2031462904 | 2017-03-09 | Salt Water Injection Well | No Violations | Inspection today revealed that contractors were on site to discuss with company rep running plug on wireline too test injection string for leaks and then pressure test annulus to check packer integrity and then determine plan of attack to repair/replace tubing and packer and retest to ensure we have proper integrity. |
2049691769 | 2018-04-15 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
|
2054487213 | 2018-11-29 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pumps were in operation during my inspection and it was noted that two HWR tankers were offloading during this time. |
2058264238 | 2018-01-02 | Salt Water Injection Well | No Violations | Producers Services were on site to perform 3000 gallon acid treatment on said well.
|
2065335083 | 2016-12-20 | Salt Water Injection Well | No Violations | Work still continues at site. |
2101955024 | 2017-03-21 | Salt Water Injection Well | No Violations | Fortis Service rig on site preparing to unload 2.875 tubing and Pioneer packer rep was on site to run test packer and tubing in well to find suspected hole in production casing. |
222982244 | 2019-11-6 0:00: | SW | No Violations | |
243758115 | 2017-8-7 0:00:0 | SW | No Violations | |
315599471 | 2017-9-29 0:00: | SW | No Violations | |
325150507 | 2018-7-17 0:00: | SW | No Violations | |
336332098 | 2017-1-31 0:00: | SC | No Violations | |
398241371 | 2020-5-11 0:00: | SW | No Violations | |
488106109 | 2017-6-15 0:00: | SW | No Violations | |
508507930 | 2017-1-26 0:00: | SW | No Violations | |
530373978 | 2018-10-29 0:00 | SW | No Violations | |
535107156 | 2019-4-17 0:00: | SW | No Violations | |
567201187 | 2016-7-11 0:00: | SW | No Violations | |
569747538 | 2018-10-2 0:00: | SW | No Violations | |
573418821 | 2016-5-27 0:00: | SW | No Violations | |
600025799 | 2016-3-18 0:00: | SW | No Violations | |
635280793 | 2019-2-20 0:00: | SW | No Violations | |
650243283 | 2017-3-13 0:00: | SW | No Violations | |
653376678 | 2016-11-8 0:00: | SW | No Violations | |
702537347 | 2016-11-30 0:00 | SW | No Violations | |
758391317 | 2018-5-18 0:00: | SW | No Violations | |
782633312 | 2019-2-11 0:00: | SW | No Violations | |
842509063 | 2018-7-11 0:00: | SW | No Violations | |
850110889 | 2018-3-4 0:00:0 | SW | No Violations | |
890886894 | 2015-10-26 0:00 | SW | No Violations | |
989617082 | 2018-1-30 0:00: | SW | No Violations |
For data sources see[4]