If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-059-24441 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.16,"lon":-81.32,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Guernsey | |
Municipality: Londonderry Township | |
Operator Name: ASCENT RESOURCES UTICA LLC | |
Well Pad ID: US-OH-001144 | |
Farm/Lease Name: HOOP LND GR | |
License Status: Producing | |
License Date: 2017-12-27 | |
Spud Date: 2014-11-14 | |
Spud Drilling Contractor: HIGHLAND DRLG | |
Final Drill Date: 2018-02-04 | |
Well Total Depth: 1630.00 ft | |
Configuration: Horizontal | |
Latitude: 40.160000 | |
Longitude: -81.320000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2014-11-10 | Proposed Formations:POINT PLEASANT, Issued Date:11/10/2014, Expired Date:11/9/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Change of Owner | 2017-12-08 | Operator changed from 8928, CARRIZO (UTICA) LLC to 9520, ASCENT RESOURCES UTICA LLC |
APP | 2017-12-27 | Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:12/27/2017, Expired Date:12/27/2019 12:00:00 PM, Drilling unit acres:898.204, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2018-02-04 | PERMIT WAS ISSUED FOR A STRAT TEST TO 6000'. ONLY DRILLED TO 1630' IN OHIO SHALE WITH INTERMEDIATE CASING SET.TA1 EXPIRED 11/9/16. |
Correction to Well | 2018-08-31 | TARGET TAKE AS-DRILLED |
Completion Report Received | 2018-10-08 | PERMIT WAS ISSUED FOR A STRAT TEST TO 6000'. ONLY DRILLED TO 1630' IN OHIO SHALE WITH INTERMEDIATE CASING SET.TA1 EXPIRED 11/9/16. |
Record Last Modified | 2018-10-19 | PERMIT WAS ISSUED FOR A STRAT TEST TO 6000'. ONLY DRILLED TO 1630' IN OHIO SHALE WITH INTERMEDIATE CASING SET.TA1 EXPIRED 11/9/16. |
Construction Permit Expires | 2019-12-27 | PERMIT WAS ISSUED FOR A STRAT TEST TO 6000'. ONLY DRILLED TO 1630' IN OHIO SHALE WITH INTERMEDIATE CASING SET.TA1 EXPIRED 11/9/16. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2018-10-18 | 7753 | 7904 | 0 |
2018-10-18 | 17293 | 17546 | 0 |
17293 | 17546 | 0 | |
7753 | 7904 | 0 | |
7753 | 7904 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 05/21/2018 | 06/10/2018 | 7556 | 14,491,100.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Ingredients | Listed Above | Listed Above | Water | 7732-18-5 | 100 | 0.386431 | 530579 |
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
MC B-8614 | Halliburton | Biocide | Listed Below | Listed Below | 0 | 0 | 0 | |
GEL 1100 | Mountain Supply & Service | Gelling Agent | Listed Below | Listed Below | 0 | 0 | 0 | |
Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 87.916 | 120,711,000.0 | |
SAND-PREMIUM WHITE-40/70, BULK | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
SP BREAKER | Halliburton | Breaker | Listed Below | Listed Below | 0 | 0 | 0 | |
FE-2A | Halliburton | Additive | Listed Below | Listed Below | 0 | 0 | 0 | |
SCALECHEK LP-70 | Halliburton | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
EXCELERATE PS-2 | Halliburton | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | Listed Below | 0 | 0 | 0 | |
Telmer | Proprietary | 10 | 0.00263518 | 3619 | ||||
Citric acid | 77-92-9 | 60 | 0.00477595 | 6558 | ||||
Acrylamide acrylate polymer | Proprietary | 30 | 0.0166937 | 22921 | ||||
Methanol | 67-56-1 | 60 | 0.000716427 | 985 | ||||
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl chlorides |
68424-85-1 | 5 | 0.00106953 | 1469 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00641715 | 8811 | ||||
Fatty acids, tall oil | Proprietary | 30 | 0.00034324 | 472 | ||||
Acrylic acid | 79-10-7 | 0.01 | 0.00000264 | 4 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 11.6568 | 16,005,000.0 | ||||
Ethoxylated alcohols | Proprietary | 30 | 0.00034324 | 472 | ||||
Sodium polyacrylate | 9003-04-7 | 1 | 0.000263518 | 362 | ||||
Hydroteated light petroleum distillate | 64742-47-8 | 30 | 0.0166937 | 22921 | ||||
Olefins | Proprietary | 5 | 0.000137296 | 190 | ||||
Inorganic salt | Proprietary | 30 | 0.0166937 | 22921 | ||||
Phosphoric acid | 7664-38-2 | 0.1 | 0.00002139 | 30 | ||||
Sodium persulfate | 7775-27-1 | 100 | 0.00000095 | 2 | ||||
Propargyl alcohol | 107-19-7 | 10 | 0.000114413 | 158 | ||||
Ethanol | 64-17-5 | 1 | 0.000213905 | 294 | ||||
Sodium sulfate | 7757-82-6 | 0.1 | 0.00000000 | 1 | ||||
Emulsifier | 9002-92-0 | 10 | 0.00000140 | 2 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.0472053 | 64814 | ||||
Ethylene glycol | 107-21-1 | 60 | 0.0158111 | 21709 | ||||
Polymer | Proprietary | 68 | 0.00000953 | 14 | ||||
Modified thiourea polymer | Proprietary | 30 | 0.00034324 | 472 | ||||
PH Buffer | 8055-55-8 | 15 | 0.00000210 | 3 | ||||
HAI-OS ACID INHIBITOR | Halliburton | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2018-05-21 | H2O | 15 | 233659 Gal | 251300 | Halliburton | STAGE 1/64
STAGES 2-63 SEE IMAGES |
2018-06-10 | H2O | 15 | 225930 Gal | 250420 | Halliburton | STAGE 64/64
STAGES 2-63 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2018 | ASCENT RESOURCES UTICA LLC | 349535 | 111617 | 162 |
2019 | ASCENT RESOURCES UTICA LLC | 182001 | 39971 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2018 | ASCENT RESOURCES UTICA LLC | Brine | 10857 | 162 |
2019 | ASCENT RESOURCES UTICA LLC | Brine | 6562 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1216540145 | 2016-10-27 0:00 | DD | No Violations | 1.00 |
-2090495234 | 2015-4-30 0:00: | PL | No Violations | 0.50 |
-2118935382 | 2019-5-1 0:00:0 | PW | No Violations | 0.30 |
-91112381 | 2020-7-15 0:00: | PW | No Violations | 1.00 |
0571623625 | 2018-07-17 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead. Multiple contractors were on location preparing the pad for flow back operations. The production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, two compressors, six sand traps, six gas production units, one vertical vent scrubber, and one combustor. |
0797954301 | 2014-12-13 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I witnessed that Highlands Drilling Rig #10 drilled a 23 inch diameter hole to the depth of 478 feet and ran 18.625 inch 87.5#/ft. J-55 casing not getting past 230 feet. Pulled casing out laid down and went in the wellbore with a 23 inch tricone bit making two trips to bottom and reaming at 230 feet. Picked up casing and began running and once again hit at 230 feet. After several unsuccessful attempts to get casing past 230 feet a decision was made to pull casing, lie down and go in and ream again. Carrizo will notify ODNR when casing is picked back up and on bottom so that cement can be witnessed. |
1216540145 | 2016-10-27 | Drill / Deepen / Reopen | No Violations | |
1427796851 | 2014-12-14 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I witnessed that Highlands Drilling Rig #10 drilled a 23 inch diameter hole to the depth of 478 feet and ran 18.625 inch 87.5#/ft. J-55 casing and made 2 unsuccessful attempts getting casing on bottom followed by reamer runs with a tricone bit. On the third attempt casing was landed at 444 feet. Baker Hughes was onsite and broke circulation and pumped 35bbls of gel and 10bbls of fresh water. As Baker was preparing to batch cement and found their vacuum brake was missing and one had to be brought down from Massillon. Upon arrival of Baker Hughes cemented casing with 665 sacks of Class A lead cement with 0.05% Static Free, 1% CaCl, 0.5% EC-1, 0.125#/sk. Cello Flake, 0.75gals/sk. FP-6L, 0.5% BA-10A, weighing 15.6ppg with a yield of 1.20cuft/sk. Lead cement was followed 209 sacks of Class A tail cement with 0.05% Static Free, 3% CaCl, 0.5% EC-1, 0.125#/sk. Cello Flake, 0.75gals/sk. FP-6L, and 0.5% BA-10A, weighing 15.6ppg with a yield of 1.21cuft/sk. Cement weight was verified by mud scales. Cement was displaced with 124bbls of fresh water. 60bbls of good cement returns to surface, plug was landed at 300psi and pressured to 1050psi for 5 minutes and the floats held. |
1551303485 | 2019-02-27 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead. Production valves were in the open position. Gauges present read 0 pounds per square inch on the 13.375-inch diameter intermediate casing and 800 pounds per square inch on the 9.625-inch diameter intermediate casing. No gauges were present on the 18.625-inch diameter surface casing. The cellar was full of water and no bubbling was present. Production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, two compressors, six sand traps, six gas production units, one vertical vent scrubber, and one combustor. Identification was located at the well, at the tank battery, and at the entry. |
2090495234 | 2015-04-30 | Preliminary Restoration | No Violations | On the day of my inspection accompanied by ODNR Inspector Matt Fulk, the site passed preliminary restoration according to ORC 1509.072A. |
2118935382 | 2019-05-01 | Production Wells | No Violations | The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead. Production valves were in the open position. Production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, two compressors, six sand traps, six gas production units, one vertical vent scrubber, and one combustor. Identification was located at the well, at the tank battery, and at the entry. Keystone Wireline Swabbing rig was parked on pad. |
571623625 | 2018-7-17 0:00: | PW | No Violations | 0.20 |
797954301 | 2014-12-13 0:00 | DD | No Violations | 4.00 |
For data sources see[10]