Well Details

Well ID: 34-059-24427
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Oxford Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001044
Farm/Lease Name: COAD OXF GR
License Status: Producing
License Date: 2014-12-05
Spud Date: 2014-12-10
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2015-03-02
Well Total Depth: 15388.00 ft
Configuration: Horizontal
Latitude: 40.030000
Longitude: -81.250000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-09-24 Proposed Formations:TRENTON, Issued Date:9/24/2014, Expired Date:9/23/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2014-12-05 Proposed Formations:POINT PLEASANT, Issued Date:12/5/2014, Expired Date:12/4/2016 12:00:00 PM, Drilling unit acres:514.638, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2015-03-02
Change of Owner 2015-08-19 Operator changed from 9193, AMERICAN ENERGY UTICA LLC to 9520, ASCENT RESOURCES UTICA LLC
Correction to Well 2015-11-06 UPDATE TO TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2016-05-20
Construction Permit Expires 2016-12-04
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2016-06-07 8389 15195 0
8389 15195 0
8389 15195 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 08/09/2015 08/21/2015 8037 9,467,090.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 PTL3050 PTL Proppant Crystalline Silica (Quartz) 14808-60-7 100 9.16933 8,237,900.0
PTLIS347 PTL Iron Stabilizer Trade Secret Agent Proprietary 100 0.00616759 5541.08
PTL100 PTL Proppant Crystalline Silica (Quartz) 14808-60-7 100 1.80232 1,619,240.0
PTLFR200 PTL Friction Reducer Aliphatic hydrocarbon Proprietary 30 0.0159586 14337.5
Oxyalkylated alcohol Proprietary 5 0.00265977 2389.59
EC6111A PTL Biocide Glutaraldehyde 111-30-8 30 0.00658097 5912.47
Trade Secret Agent Proprietary 100 0.0219366 19708.2
PTLAI161 PTL Corrosion Inhibitor Fatty Alcohol Ethoxylate Proprietary 30 0.00004541 40.8
Ethoxylated alcohol Proprietary 10 0.00001514 13.6
Alkyl Amine Surfactant Proprietary 5 0.00000757 6.8
Isopropyl Alcohol 67-63-0 60 0.00009083 81.6
Aromatic aldehyde Proprietary 10 0.00001514 13.6
PTLGL341 PTL Guar Trade Secret Agent Proprietary 100 0.0118429 10639.9
PTLBW102 PTL Breaker Ammonium Persulphate 7727-54-0 100 0.000194787 175
PTLMP115 PTL 15% HCL Water 7732-18-5 90 0.879439 790105
Hydrochloric acid 7647-01-0 20 0.195431 175579
PTLSI372 PTL Scale Inhibitor Trade Secret Agent Proprietary 100 0.0219674 19735.9
Water PTL Carrier/Base Fluid Water 7732-18-5 100 87.9355 79,002,900.0
PTLBW112 PTL Breaker Ammonium Persulphate 7727-54-0 100 0.00029051 261

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2015-08-09 H2O 0 0 Bbl 251781 STAGE 1/40

30 SHOTS STAGES 2-39 SEE IMAGES

2015-08-21 H2O 0 0 Bbl 247280 STAGE 40/40

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2015 ASCENT RESOURCES UTICA LLC 379139 21755 74
2016 ASCENT RESOURCES UTICA LLC 1302999 33996 366
2017 ASCENT RESOURCES UTICA LLC 727738 5837 365
2018 ASCENT RESOURCES UTICA LLC 474052 2948 365
2019 ASCENT RESOURCES UTICA LLC 93787 451 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2015 ASCENT RESOURCES UTICA LLC Brine 6327 74
2016 ASCENT RESOURCES UTICA LLC Brine 12379 366
2017 ASCENT RESOURCES UTICA LLC Brine 6152 365
2018 ASCENT RESOURCES UTICA LLC Brine 3996 365
2019 ASCENT RESOURCES UTICA LLC Brine 581 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1016541854 2015-2-13 0:00: DD No Violations 18.00
-114028449 2014-12-7 0:00: DD No Violations 4.00
-1256164700 2017-6-7 0:00:0 PW No Violations 0.30
-1476672125 2015-2-24 0:00: DD No Violations 2.00
-1547697992 2017-2-8 0:00:0 PW No Violations 0.20
-1554327456 2014-12-10 0:00 DD No Violations 1.00
-1872628526 2015-4-2 0:00:0 DD No Violations 2.00
-1903397455 2015-2-17 0:00: DD No Violations 4.00
-1906117493 2016-6-23 0:00: PW No Violations 3.00
-1982450997 2020-5-29 0:00: PW No Violations 1.00
-2076881341 2015-3-20 0:00: AM No Violations
-387161517 2015-2-19 0:00: DD No Violations 3.00
-590372835 2018-5-22 0:00: PW No Violations 0.30
-916031030 2019-3-6 0:00:0 PW No Violations 0.30
0047484209 2015-03-05 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-
0114028449 2014-12-07 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Precision Rathole had found the bottom of the void and TOC at 33 feet and added pea gravel to make a bridge to 27 feet. Express Energy was on site and pumped 8 yards of ready mix to get cement to surface.
0225895696 2016-06-22 Production Wells No Violations On the day of my inspection I witnessed that the well is online and equipped with a NEECO production tree with valves in the open position. Production equipment included a sand trap and a GP Unit. Also present a line heater, a vapor recovery system, 1- NGL tank, a compressor unit, a heater treater, a stabilizer unit, a vertical vent scrubber, a combustor unit and a total of 12-
0355929197 2015-04-17 Preliminary Restoration No Violations On the day of my inspection the site passed preliminary restoration according to ORC 1509.072A.
0387161517 2015-02-19 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-1016541854, witnessed that Nomac Drilling Rig #81was drilling ahead on air with a 12.25 inch diameter bit at depth of 5048 feet with a planned td of 7100 feet. Reviewed Myers Well Service run sheets with AEU Consultant Larry Henry and a total of 830bbls has been gathered at this point and taken to the rig with the current Myers Well Service truck at 20% capacity. Testing with Quantabs revealed levels at the springhouse 40.035523 -81.255717 were at 421ppm and the north roadside sump 40.035494 -81.255616 were at 665ppm with a pH of 7 and no visible solids or sheen. I then met with AEU EHS Field Representative Tom Bauer, he is having Sunpro power wash and pump out the springhouse to remove any residual solids in the bottom with further testing after cleaning.
0575468942 2014-12-11 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that the TOC was at 12 feet and Express Energy Services was on site and successfully topped of cement to the surface.
0590372835 2018-05-22 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of four 400 barrel tanks, one vapor recovery tower, four sand traps, four gas production units, one vertical vent scrubber, and one combustor.
0763490169 2015-03-02 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-1016541854, witnessed that Nomac Drilling Rig #81 had reached a total depth of 15388 feet, ran and set 15388 feet of 5.5 inch 23#ft P-110 casing and were in the process of rigging down. A total of 1465bbls has been gathered at this point and taken to the rig with the current Myers Well Service truck at 60% capacity. Testing with Quantabs revealed chloride levels at the springhouse 40.035523 -81.255717 were at 203ppm and the north roadside sump 40.035494 -81.255616 were at 350ppm with a pH of 7 and no visible solids or sheen.
0916031030 2019-03-06 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with production valves in the open position. Annular pressure monitoring was present with gauges present reading 600 pounds per square inch on the 13.375-inch diameter surface casing and 1100 on the 9.625-inch diameter intermediate casing. The production equipment consisted of four sand traps, four gas production units, one vertical vent scrubber, one vapor recovery tower, and four 400-barrel tanks with vent lines plumbed into one combustor.
1016541854 2015-02-13 Drill / Deepen / Reopen Violations Noted On the day of my inspection I witnessed that Nomac Drilling Rig #81 that the rig was still tripping out of the hole after setting a 40bbl gel pill I left location. Upon return I witnessed that Nomac Drilling Rig #81 had drilled a 17.5 inch diameter hole to the depth of 1275 feet and Franks Casing crew was completing a run of 1248 feet of 13.375 inch 54.5#/ft. J---81.255527 were at 2500ppm and near Salt Fork Creek 40.034531 -81.255584 were at 3700ppm. Fluid level remained at 108 feet in the wellbore while flow remained the same at the springhouse. Three sumps were lined to prevent any water reaching Salt Fo
1171729877 2015-03-04 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-1016541854, I witnessed that Nomac Drilling Rig #81 continuing to rig down. A total of 2845bbls has been gathered and taken to the rig with 1300bbls of the total coming from the rainfall since yesterday. Testing with Quantabs revealed chloride levels at the springhouse 40.035523 -81.255717 were at 188ppm and the north roadside sump 40.035494 -81.255616 were at 236ppm with a pH of 6 and no visible solids or sheen. With the current readings and rain fall pumping from the sumps has ceased. Full analytical testing results will be furnished to ODNR upon completion.
1191851762 2015-02-20 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-1016541854, witnessed that Nomac Drilling Rig #81was broke down waiting on another booster at depth of 6400 feet and a planned td of 7100 feet. A total of 880bbls has been gathered at this point and taken to the rig with the current Myers Well Service truck broke down at 60% capacity and a mechanic arriving getting the truck back in operation. Testing with Quantabs revealed chloride levels at the springhouse 40.035523 -81.255717 were at 400ppm and the north roadside sump 40.035494 -81.255616 were at 584ppm with a pH of 7 and no visible solids or sheen. I met with Dan Sansone of Hull & Associates as he took samples and completed field test on the springhouse with chloride levels at 365ppm and an EC of 1.98mS with the other samples getting complete testing for chlorides, metals and solids.
1256164700 2017-06-07 Production Wells No Violations On the day of my inspection I witnessed that the well is online and equipped with a NEECO production tree with valves in the open position. Production equipment included a sand trap and a GP Unit. Also present a line heater, a vapor recovery system, 1- NGL tank, a compressor unit, 2-horizontal heated separator (1 disconnected), a stabilizer unit, a vertical vent scrubber, a combustor unit and a total of 12-400 barrel tanks all within containment and shared with the 6H, 4H and 2H. Gauges present read 400 pounds per square inch on the tubing and 500 pounds per square inch on the casing with annular pressure monitoring in place.
1417714874 2014-12-04 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Precision Rathole had drilled a 36 inch diameter hole to the depth of 100 feet and ran 100 feet of 30 inch 118.65#/ft. conductor pipe. Universal Well Service was on site gained circulation and cemented pipe with 270 sacks Type 1 cement with 3% CaCl and .25#/sk. of floseal and a yield of1.2 cuft/sk. Cement was displaced with 74bbls of fresh water. No cement returns to surface instructed operator to run one inch tubing and bring cement to surface.
1417824299 2014-12-05 Administrative Inspection No Violations At 4:50 PM I received a call from AEU Drilling Superintendent Richard Thomas stating that they had ran 1 inch tubing down the backside of the conductor for remedial cement job ran some LCM, 5bbls of cement and CaCl pulled out and waited 2 hours. Land owner showed up with a sample from her spring which appeared to have gel in it. AEU shut down operations and contacted ODNR. I then contacted land owner Darlene Crooks and she stated that when she turned the water on this morning it was grey and then she went to work and upon returning the water was still discolored. She went to her spring house and it was full of grey and murky water. Complaint was taken and forwarded to ODNR Hydrologist Kyle Tharp for investigation.
1417886358 2014-12-06 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Precision Rathole had ran some LCM and Universal Well Service had pumped 2.5bbls of Type1 Cement weighing 15.6ppg with a yield of 1.19cuft/sk. through 1 tubing and waited 1 hour. Universal pumped 5bbls of Type 1 Cement weighing 15.6ppg with a yield of 1.19cuft/sk. through 1 inch tubing and waited 30 minutes. Universal pumped remaining cement for a total of 600sks with no cement to surface. Precision pumped an additional 7yds of ready mix with no cement to surface. AEU will shut down make a plan and notify ODNR before they proceed.
1423931781 2015-02-14 Casing String Witnessed No Violations I arrived on location at 10:30 AM at the request of inspector Doug Bennett. During an effort to load the hole and gain circulation, a developed spring to the south of the location was communicated with. An attempt to cement the 1248 of casing to surface was made with 1170 sacks of class H cement with .5 pounds per gallon Celloflake and 2% CaCl. Circulation could not be gained and no returns were witnessed at surface. After four hours, one inch tubing was ran inside the annular space to find the cement top. The cement top was found at 110. Once the cement top was tagged, a large amount of cotton seed hulls were poured into the annular space of the casing string. In addition, enough pea gravel was placed to cover twelve feet of the annular space. While placing the lost circulation materials the annular space was bridged off at twenty feet from surface. Several attempts to clear the obstruction were made with the one inch tubing. O-Tex then placed twenty two barrels of class H cement on top of the obstruction causing it to move downhole approximately fifteen feet. The spring that was impacted, was flowing much clearer at the time of my departure than when I arrived and the chlorides were down to 2400 ppm.
1424283870 2015-02-18 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-1016541854, witnessed that Nomac Drilling Rig #81had reached a depth of 3832 feet and tripping out of the hole due to a WMD failure. Reviewed Myers Well Service run sheets with AEU Consultant Larry Henry and a total of 760bbls has been gathered at this point and taken to the rig with the current Myers Well Service truck at 35% capacity. Testing with Quantabs revealed levels at the springhouse 40.035523 -81.255717 were at 533ppm and the north roadside sump 40.035494 -81.255616 were at 820ppm with a pH of 6 and no visible solids or sheen.
1476672125 2015-02-24 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-1016541854, witnessed that Nomac Drilling Rig #81had landed their curve at 8529 feet and was drilling an 8.5 inch diameter lateral hole at a depth of 8854 feet on 10.6# SOBM with a planned td of 15436 feet. A total of 1125bbls has been gathered at this point and taken to the rig with the current Myers Well Service truck at 40% capacity. Testing with Quantabs revealed chloride levels at the springhouse 40.035523 -81.255717 were at 219ppm and the north roadside sump 40.035494 -81.255616 were at 423ppm with a pH of 7 and no visible solids or sheen.
1547697992 2017-02-08 Production Wells No Violations On the day of my inspection I witnessed that the well is online and equipped with a NEECO production tree with valves in the open position. Production equipment included a sand trap and a GP Unit. Also present a line heater, a vapor recovery system, 1- NGL tank, a compressor unit, a heater treater, a stabilizer unit, a vertical vent scrubber, a combustor unit and a total of 12-400 barrel tanks all within containment and shared with the 6H, 4H and 2H. Gauges present read 550 pounds per square inch on the tubing and 750 pounds per square inch on the casing with annular pressure monitoring in place.
1554327456 2014-12-10 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Precision Rathole had drilled a 36 inch diameter hole to the depth of 100 feet and ran 100 feet of 30 inch 118.65#/ft. conductor pipe. Universal Well Service was on site doing a balanced job and cemented pipe with 150 sacks Type 1 cement with 3% CaCl and .25#/sk. of floseal and a yield of 1.2cuft/sk. Cement was displaced with 74bbls of fresh water with full returns cement was at 10 feet and will be topped off tomorrow.
1682120583 2015-02-11 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Nomac Drilling Rig #81 had cemented their 5.5 inch production string on 34059243450000 Coad 6H and was walking rig over to the 8H with plans to re-spud well this evening.
1702991270 2015-02-26 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-1016541854, witnessed that Nomac Drilling Rig #81was drilling an 8.5 inch diameter lateral hole at a depth of 13 feet on 11.1# SOBM with a planned td of 15436 feet. A total of 1225bbls has been gathered at this point and taken to the rig with the current Myers Well Service truck at 50% capacity. Testing with Quantabs revealed chloride levels at the springhouse 40.035523 -81.255717 were at 294ppm and the north roadside sump 40.035494 -81.255616 were at 637ppm with a pH of 7 and no visible solids or sheen.
1872628526 2015-04-02 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV-1016541854, I witnessed that remediation of the bottom near Salt Fork Creek was complete. Testing with Quantabs revealed chloride levels at the springhouse 40.035523 -81.255717 were at 63ppm and the north roadside 40.035494 -81.255616 were at 71ppm with a pH of 6 and no visible solids or sheen. AEU EHS Field Tech Amy Louwers stated full analytical testing results will be furnished to ODNR next week with all initial test levels within normal ranges. NOV-1016541854 is resolved.
1903397455 2015-02-17 Drill / Deepen / Reopen No Violations On the day of my inspection following up on NOV--81.255717 were at 755ppm and the north roadside sump 40.035494 -81.255616 were at 964ppm with a pH of 6 and no visible solids. The other sumps were frozen over with no flow reaching the south side of the Oxford Road. A total of 710bbls has been gathered at this point and taken to the rig with the current Myers Well Service truck at 40% capacity.
1906117493 2016-06-23 Production Wells No Violations On the day of my inspection I met with Ascent Resources Production Foreman Kelly Swope and witnessed Cameron Services rig up their choke manifold and relief the pressure on the between the 9.625 inch casing and the 5.5 inch casing. Pressure was relieved from 1900psi to 620psi and shut-in for continued monitoring.
2076881341 2015-03-20 Administrative Inspection No Violations Discussion with Bob Adams on NOV-1016541854, 2 week extension granted clean-up should be completed by the end of next week depending on the weather.
225895696 2016-6-22 0:00: PW No Violations 0.50
340503221 2020-5-20 0:00: PW No Violations 1.00
355929197 2015-4-17 0:00: PL No Violations 0.20
47484209 2015-3-5 0:00:0 DD No Violations 1.00
575468942 2014-12-11 0:00 DD No Violations 2.00
763490169 2015-3-2 0:00:0 DD No Violations 1.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1016541854 US-OH-100010 2015-04-21 Drilling operation causing pollution and contamination

For data sources see[10]