X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24415

Well Details

Well ID: 34-059-24415
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Oxford Township
Operator Name: ECLIPSE RESOURCES I LP
Well Pad ID: US-OH-001114
Farm/Lease Name: FINERAN A
License Status: Producing
License Date: 2019-01-14
Spud Date: 2014-08-30
Spud Drilling Contractor: H&P DRILLING
Final Drill Date: 2018-12-28
Well Total Depth: 24845.00 ft
Configuration: Horizontal
Latitude: 40.020000
Longitude: -81.340000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-08-25 Proposed Formations:TRENTON, Issued Date:8/25/2014, Expired Date:8/24/2016 12:00:00 PM, Drilling unit acres:683.601, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2016-12-16 Proposed Formations:TRENTON, Issued Date:12/16/2016, Expired Date:12/16/2018 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Correction to Well 2018-04-12 PLAT CHANGE TAKE/TARGET
APP 2018-10-30 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:10/30/2018, Expired Date:10/29/2020 12:00:00 PM, Drilling unit acres:288.147, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2018-12-28
APP 2019-01-14 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:1/14/2019, Expired Date:1/13/2021 12:00:00 PM, Drilling unit acres:662.576, Proposed Well Type:OG, Proposed Well Class:POOL
Record Last Modified 2019-04-08
Construction Permit Expires 2021-01-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
24593 24697 0
7617 7739 0
7617 7739 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1837606780 2019-2-12 0:00: CT No Violations 0.20
-1864518136 2018-11-8 0:00: PW No Violations 5.00
-199616459 2018-12-20 0:00 DD No Violations 0.50
-473762221 2020-6-11 0:00: PW No Violations 1.00
-666644086 2019-12-11 0:00 PW No Violations 0.20
-96679707 2019-1-22 0:00: DD No Violations 0.10
-97928608 2015-2-13 0:00: DD No Violations 1.50
0096679707 2019-01-22 Drill / Deepen / Reopen No Violations Drilling operations have been completed and the well awaits completion within the point pleasant formation.
0097928608 2015-02-13 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Precision Drilling Rig #110 was drilling ahead on 10.8# SOBM at with a 12 inch tricone bit at depth of 6497 feet with a planned td of 6700 feet and 9.625 inch casing and cementing to follow. Completed walk around with Consultants Ben Keyser and Jeb Dobbs revealing no violations.
0199616459 2018-12-20 Drill / Deepen / Reopen No Violations
1411321507 2014-09-21 Casing String Witnessed No Violations On the day of my inspection I witnessed that Alpha Hunter Drilling Rig #9 had drilled a 22inch diameter hole to the depth of 439 feet and ran 439 feet of 18.625 inch 87.5#/ft. J-55 casing. Halliburton was on site gained circulation with 165bbls fresh water then pumped 25bbls of gel, 10bbls of fresh water and cemented casing with 714 sacks of Class A lead cement with a weight of 15.6ppg verified by mud scales and a yield of 1.18 followed by 200 sacks of BondCem cement with a weight of 15.8ppg verified by mud scales and a yield of 2.31cuft/sk. Cement was displaced with 115bbls of fresh water. Good cement returns of 147bbls to surface.
1460725958 2019-04-30 Completion Testing No Violations The purpose of my inspection was a status check on completion operations. During my inspection the well had just recently had 113 stages of frac plugs drilled out and production tubing installed. A service rig was on location rigged up on the 7H well drilling out frac plugs.
1541010443 2019-05-28 Completion Testing No Violations The purpose of my inspection was a status check. During my inspection the wells were being prepared for flow back operations. Deep Well Snubbing Unit rig number 15 was being hauled from location. Production equipment was being assembled on location.
1557767167 2019-05-13 Completion Testing No Violations The purpose of my inspection was a status check on fishing operations. 2.875-inch diameter tubing was being utilized to drill out frac plugs and after drilling out the last frac plug the bottom of the tubing string was at 24,500-feet and the tubing string parted at 675-feet. Deep Well standalone snubbing unit 15 was rigged up on the well. I spoke with Eclipse Company Man Don Barker and he stated that the snubbing unit had just successfully latched on to the tubing string.
1619984899 2014-09-23 Drill / Deepen / Reopen No Violations On the day of my inspection accompanied by ODNR Inspector Justin Smith, I witnessed that Alpha Hunter Drilling Rig #9 had ran and cemented 1449 feet of 13.375 inch casing and was preparing to drill out the float equipment.
1713179220 2015-04-29 Preliminary Restoration No Violations On the day of my inspection accompanied by Southeast Regional Supervisor Brent Bear, the site passed preliminary restoration according to ORC 1509.072A.
1837606780 2019-02-12 Completion Testing No Violations The well was awaiting hydraulic stimulation operations. Pro Frac Services were on location pumping the first stage on the 7 H 3405924418.
1864518136 2018-11-08 Production Wells No Violations The purpose of my inspection was to witness temporary abandonment activities on well #2-4415. At the time of my inspection I met with Eclipse Resources Environmental, Health, Safety and Regulatory Manager Bruce Carpenter to discuss the operations for the day and review the submitted and approved SIMOPS plan. The surface equipment on location would be outside of the fall radius of the drilling rig. Well #2-4415 had tubing isolation plugs set at 1740 and 1706 inside the tubing due to failed attempts to set plugs in the profile nipples. I witnessed the residual tubing pressure bled off prior to the setting of the back pressure valve and one of two valve recovery plugs in the well head. The intermediate and production casing annular pressure gauges were plumbed above grade and labeled. Both gauges indicated 300 psi. The gauges would remain above grade during operations. Following the temporary abandonment of the well, a steel cage would be placed over the well head.

For data sources see[4]