34-059-24302

Well Details

Well ID: 34-059-24302
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Londonderry Township
Operator Name: GULFPORT APPALACHIA LLC
Well Pad ID: US-OH-000533
Farm/Lease Name: RIPLEY
License Status: Producing
License Date: 2013-07-19
Spud Date: 2014-05-13
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2014-07-04
Well Total Depth: 14140.00 ft
Configuration: Horizontal
Latitude: 40.140000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-07-19 Proposed Formations:POINT PLEASANT, Issued Date:7/19/2013, Expired Date:7/19/2015 12:00:00 PM, Drilling unit acres:625.078, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2014-06-27 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE DECREASED TO 623.320 ACRES.
Reached Total Depth 2014-07-04
Correction to Well 2015-01-09 UPDATE TO TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM NEW PLAT.
Completion Report Received 2015-06-15
Construction Permit Expires 2015-07-19
Record Last Modified 2017-10-24

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/21/2014 10/01/2014 7574 11,408,800.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRA-407 Operator Friction Reducer Water 7732-18-5 55 0.06127 0
Petroleum distillates, hydrotreated light 64742-47-8 40 0.04456 0
Ammonium acetate 631-61-8 5 0.00557 0
SAND - PREMIUM WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 9.7358 0
LCA-1 Halliburton Solvent Paraffinic solvent Confidential 100 0.00130463 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Propargyl alcohol 107-19-7 10 0.00007895 0
Methanol 67-56-1 60 0.000470906 0
OptiKleen-WF(TM) Halliburton Concentrate Sodium perborate tetrahydrate 10486-00-7 100 0.0122031 0
SP BREAKER Halliburton Breaker Sodium persulfate 7775-27-1 100 0.000239683 0
Other Purpose Fatty alcohol polyglycol ether surfactant 9043-30-5 0 0.000191746 0
Ammonium chloride 12125-02-9 0 0.00561515 0
Quaternary ammonium compounds,

bis(hydrogenated tallow alkyl) dimethyl,salts with bentonite

68953-58-2 0 0.000958731 0
Polyacrylamide copolymer Confidential 0 0.03369 0
Sodium sulfate 7757-82-6 0 0.00000094 0
Sorbitan monooleate polyoxyethylene derivative 9005-65-6 0 0.00112322 0
Fatty acids, tall oil Confidential 0 0.000235923 0
Sodium chloride 7647-14-5 0 0.00561515 0
Sorbitan, mono-9-octadecenoate, (Z) 1338-43-8 0 0.00112322 0
Water 7732-18-5 0 0.0863816 0
Organic phosphonate Confidential 0 0.00591875 0
Reaction product of acetophenone,

formaldehyde, thiourea and oleic acid in dimethyl formamide

68527-49-1 0 0.000235923 0
Crystalline silica, quartz 14808-60-7 0 0.00001974 0
Alcohols ethoxylated Confidential 0 0.00561515 0
Amide Confidential 0 0.00561515 0
Olefins Confidential 0 0.00003948 0
Formaldehyde 50-00-0 0 0.00009869 0
Olefins Confidential 0 0.00000846 0
Alcohols, C14-C15, ethoxylated 68951-67-7 0 0.000235923 0
HCl 7.5% Halliburton Solvent Hydrochloric Acid 7647-01-0 7.5 0.0426353 0
Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 89.4334 0
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.000872257 0
HCl 15% Halliburton Solvent Hydrochloric Acid 7647-01-0 15 0.0126186 0
FE-2A Halliburton Additive Citric acid 77-92-9 60 0.00436974 0
LGC-36 UC Halliburton Liquid Gel Concentrate Guar gum 9000-30-0 60 0.0114982 0
Naphtha, hydrotreated heavy 64742-48-9 60 0.0114982 0
FE-1A ACIDIZING COMPOSITION Halliburton Additive Acetic anhydride 108-24-7 100 0.00631822 0
Acetic acid 64-19-7 60 0.00379075 0
Scalechek(R) LP-65 Scale Inhibitor Halliburton Scale Inhibitor Ammonium chloride 12125-02-9 10 0.000986928 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
1 H2O 0 9313 Bbl 379300 2014-09-22 Perforations

13807-6 shots 13768-6 shots 13729-6 shots 13690-6 shots 13650-6 shots 9 clusters @ .052","US-OH-26005

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 GULFPORT ENERGY CORPORATION 60485 14309 30
2015 GULFPORT ENERGY CORPORATION 521086 104457 343
2016 GULFPORT ENERGY CORPORATION 284154 35499 364
2017 GULFPORT ENERGY CORPORATION 179870 21234 357
2018 GULFPORT ENERGY CORPORATION 146182 14916 351
2019 GULFPORT ENERGY CORPORATION 32946 3262 90

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 GULFPORT ENERGY CORPORATION Brine 6064 30
2015 GULFPORT ENERGY CORPORATION Brine 21528 343
2016 GULFPORT ENERGY CORPORATION Brine 8187 364
2017 GULFPORT ENERGY CORPORATION Brine 4319 357
2018 GULFPORT ENERGY CORPORATION Brine 3321 351
2019 GULFPORT ENERGY CORPORATION Brine 661 90

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1045689115 2019-2-14 0:00: PW No Violations 0.30
-210128488 2015-1-12 0:00: PL No Violations 0.50
-353147867 2014-9-22 0:00: CT No Violations 3.00
-80099828 2020-10-22 0:00 PW No Violations 1.00
0210128488 2015-01-12 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A.
0353147867 2014-09-22 Completion Testing No Violations On the day of my inspection I witnessed Halliburton was on site and frac stage 2 of 30. Met with Company Man Dominic Herrald and completed walk around revealing no violations. Crews were preparing the 4H for stimulation as the 1H and 2H are completed.
0453336807 2014-06-23 Casing String Witnessed No Violations On the day of my inspection I witnessed Patterson UTI Drilling Rig #257 drilled a 17.5 inch diameter hole to the depth of 359 feet and Franks Casing crew ran 353 feet of 13.375 inch 54.5#/ft. J-55 Surface Casing. Stingray Cementing was on site and gained circulation with 110bbls of fresh water. Stingray Cementing pumped 25bbls of gel, 10bbls of fresh water and cemented casing with 440 sacks of class A cement 15.6ppg, 1.2cuft/sk cement. Displaced cement with 50bbls of fresh water had good cement returns of 3bbls, plug was landed at 172psi and pressured to 672psi for 5 minutes and the floats held.
0743364550 2016-04-07 Production Wells No Violations On the day of my inspection I witnessed that the location was gated and locked. The production equipment included 8-400bbl tanks and 1-50bbl tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 2-26H, and Ripley 4-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 250psi on the tubing and 500psi on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
0918516066 2017-07-25 Production Wells No Violations On the day of my inspection I witnessed the production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 2-26H, and Ripley 4-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a plunger lift system with valves in the open position with 290 pounds per square inch on the tubing and 400 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
1030115693 2016-09-06 Production Wells No Violations On the day of my inspection I witnessed that the location was gated and locked. The production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 2-26H, and Ripley 4-26H. Also present a horizontal line heater, a vertical separator and a sand trap. . The well was equipped with a production tree with valves in the open position with 200 pounds per square inch the tubing and 450 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
1045689115 2019-02-14 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present with valves reading 0 pounds per square inch on the 13.375-inch diameter surface casing, and 500 pounds per square inch on the 9.625-inch diameter intermediate casing. The production equipment on pad consisted of four vertical separators, four sand traps, four horizontal indirect line heaters, one vertical heater treater, eight 400-barrel tanks, one 50-barrel tank, one vapor recovery tower, one gas combustor, and one flare stack. Identification was located on the wellhead.
1144127239 2017-02-07 Production Wells No Violations On the day of my inspection I witnessed the production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 2-26H, and Ripley 4-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 200 pounds per square inch on the tubing and 500 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
1400023434 2014-05-13 Drill / Deepen / Reopen No Violations On the day of my inspection accompanied by ODNR Inspector Dylan Pendleton, I witnessed Express Energy Services drilled a 32 inch diameter hole to the depth of 104 feet and ran 110 feet of 26 inch 102.63#/ft conductor pipe. Stingray Cementing was on site and gained circulation with 46bbls of fresh water. Stingray Cementing pumped 15bbls of gel, 10bbls of fresh water and cemented pipe with 236 sacks of class A cement. Good returns of 15bbls and cement stayed surface.
1409147646 2014-08-27 Completion Testing No Violations On the day of my inspection I witnessed that completion rigs was on site and had just perforated the 1st stage from 13847-45, 13808-06, 13768-66, 13829-29 and 13689-87 with 9 shots each for a total of 45 shots. Currently tripping out of the hole to check guns and then rig down to move over to the Ripley 2H. Completed walk around with Company Man Brandon Baptiste revealing no violations.
1749253269 2018-05-02 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. The production equipment consisted of eight 400 barrel tanks, one 50 barrel tank, a vapor recovery tower, two compressors, a vertical heater treater, a gas combustor, back-up flare stack, a horizontal line heater, a vertical separator, and a sand trap.
1985363031 2018-04-19 Production Wells No Violations The purpose of my inspection was to follow up on a fire that occurred on the Northeast side of the pad. The containment under the vertical heater treater ignited and caught fire which eventually spread to the vegetation beside the pad. During my inspection the wells were shut in and contractors were installing new containment under the vertical heater treater. The production equipment consisted of eight 400 barrel tanks, one 50 barrel tank, a vapor recovery tower, two compressors, a vertical heater treater, a gas combustor, back-up flare stack, a horizontal line heater, a vertical separator, and a sand trap.
453336807 2014-6-23 0:00: CS No Violations 7.00
743364550 2016-4-7 0:00:0 PW No Violations 0.30
918516066 2017-7-25 0:00: PW No Violations 0.50

For data sources see[9]

References