34-059-24301

Well Details

Well ID: 34-059-24301
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Londonderry Township
Operator Name: GULFPORT APPALACHIA LLC
Well Pad ID: US-OH-000533
Farm/Lease Name: RIPLEY
License Status: Producing
License Date: 2013-07-19
Spud Date: 2014-05-14
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2014-06-19
Well Total Depth: 14370.00 ft
Configuration: Horizontal
Latitude: 40.140000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-07-19 Proposed Formations:POINT PLEASANT, Issued Date:7/19/2013, Expired Date:7/19/2015 12:00:00 PM, Drilling unit acres:625.078, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2013-07-26 CORRECTION TO SURFACE FOOTAGE
Reached Total Depth 2014-06-19
Correction to Well 2014-06-27 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE DECREASED TO 623.320 ACRES.
Correction to Well 2015-01-09 UPDATE TO TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM NEW PLAT.
Completion Report Received 2015-06-15
Construction Permit Expires 2015-07-19
Record Last Modified 2017-10-24

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/03/2014 10/16/2014 7536 12,241,400.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 88.2023 0
OptiKleen-WF(TM) Halliburton Concentrate Sodium perborate tetrahydrate 10486-00-7 100 0.0105926 0
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.000874444 0
HCl > 10% Halliburton Solvent Hydrochloric Acid 7647-01-0 100 0.0580616 0
HCl < 10% Halliburton Solvent Hydrochloric Acid 7647-01-0 100 0.541822 0
40/70 White Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 2.41537 0
Crystalline silica, quartz 14808-60-7 100 8.64981 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Methanol 67-56-1 60 0.000257662 0
Propargyl alcohol 107-19-7 10 0.00004294 0
LCA-1 Halliburton Solvent Paraffinic solvent Confidential 100 0.00134051 0
FE-1A ACIDIZING COMPOSITION Halliburton Additive Acetic anhydride 108-24-7 100 0.00345737 0
Acetic acid 64-19-7 60 0.00207442 0
LP-65 Halliburton Scale Inhibitor Ammonium chloride 12125-02-9 10 0.00101796 0
Other Purpose Amide Confidential 0 0.00469418 0
Sorbitan monooleate polyoxyethylene derivative 9005-65-6 0 0.000938836 0
Olefins Confidential 0 0.00000429 0
Fatty acids, tall oil Confidential 0 0.000128831 0
Polyacrylamide copolymer Confidential 0 0.0281651 0
Sodium chloride 7647-14-5 0 0.00469418 0
Alcohols ethoxylated Confidential 0 0.00469418 0
Alcohols, C14-C15, ethoxylated 68951-67-7 0 0.000128831 0
Water 7732-18-5 0 0.0735734 0
Reaction product of acetophenone,

formaldehyde, thiourea and oleic acid in dimethyl formamide

68527-49-1 0 0.000128831 0
Olefins Confidential 0 0.00002147 0
Sorbitan, mono-9-octadecenoate, (Z) 1338-43-8 0 0.000938836 0
Formaldehyde 50-00-0 0 0.000101796 0
Ammonium chloride 12125-02-9 0 0.00469418 0
Organic phosphonate Confidential 0 0.00610779 0
FRA-407 Weatherford Friction Reducer Ammonium acetate 631-61-8 5 0.00352063 0
Petroleum distillates, hydrotreated light 64742-47-8 40 0.0281651 0
FE-2A Halliburton Additive Citric acid 77-92-9 60 0.00239107 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
8 0 0
2014-10-03 H2O 15 401181 Gal 400900 Halliburton STAGE 1/32

45 SHOTS

2014-10-16 H2O 0 386045 Gal 406300 Halliburton STAGE 32/32

45 SHOTS

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 GULFPORT ENERGY CORPORATION 62134 14646 29
2015 GULFPORT ENERGY CORPORATION 563507 126408 340
2016 GULFPORT ENERGY CORPORATION 358873 54319 364
2017 GULFPORT ENERGY CORPORATION 244437 31031 357
2018 GULFPORT ENERGY CORPORATION 189803 19257 349
2019 GULFPORT ENERGY CORPORATION 31459 3276 90

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 GULFPORT ENERGY CORPORATION Brine 5966 29
2015 GULFPORT ENERGY CORPORATION Brine 32521 340
2016 GULFPORT ENERGY CORPORATION Brine 9164 364
2017 GULFPORT ENERGY CORPORATION Brine 5975 357
2018 GULFPORT ENERGY CORPORATION Brine 6840 349
2019 GULFPORT ENERGY CORPORATION Brine 1099 90

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1364803740 2018-5-2 0:00:0 PW No Violations 0.50
-137720071 2016-4-7 0:00:0 PW No Violations 0.30
-146440695 2014-5-21 0:00: DD No Violations 2.00
-1879914567 2015-1-12 0:00: PL No Violations 0.50
-2073491812 2016-9-6 0:00:0 PW No Violations 0.20
-2137550092 2019-2-14 0:00: PW No Violations 0.30
-80553823 2014-6-4 0:00:0 CS No Violations 9.00
0013743380 2017-07-25 Production Wells No Violations On the day of my inspection I witnessed the production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 2-26H, and Ripley 3-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a plunger lift system with valves in the open position with 260 pounds per square inch on the tubing and 310 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
0080553823 2014-06-04 Casing String Witnessed No Violations On the day of my inspection I witnessed Patterson UTI Drilling Rig #257 drilled a 17.5 inch diameter hole to the depth of 354 feet and Franks Casing crew ran 354 feet of 13.375 inch 54.5#/ft. J-55 Surface Casing. Stingray Cementing was on site and gained circulation with 124bbls of fresh water. Stingray Cementing pumped 25bbls of gel, 10bbls of fresh water and cemented casing with 478 sacks of class A cement. Good returns of 12bbls, floats did not hold, pressured up and shut in cement head.
0137720071 2016-04-07 Production Wells No Violations On the day of my inspection I witnessed that the location was gated and locked. The production equipment included 8-400bbl tanks and 1-50bbl tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 2-26H, and Ripley 3-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 700psi on the tubing and 400psi on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
0146440695 2014-05-21 Drill / Deepen / Reopen No Violations On the day of my inspection Nomac Drilling Rig #257 had begun to move on site with the rig moving from Pennsylvania. I met with Company Men Frank Bean and Jimmy Linger and did walk around. Cellars were being sealed at the time of inspection. No violations.
0954386798 2018-04-19 Production Wells No Violations The purpose of my inspection was to follow up on a fire that occurred on the Northeast side of the pad. The containment under the vertical heater treater ignited and caught fire which eventually spread to the vegetation beside the pad. During my inspection the wells were shut in and contractors were installing new containment under the vertical heater treater. The production equipment consisted of eight 400 barrel tanks, one 50 barrel tank, a vapor recovery tower, two compressors, a vertical heater treater, a gas combustor, back-up flare stack, a horizontal line heater, a vertical separator, and a sand trap.
0955680054 2014-05-29 Drill / Deepen / Reopen No Violations I am onsite today to attend the Pre-Spud meeting which consisted of Location, Permit, Regulatory, Geology, Completion, Drilling, Casing Strings, Cementing, Production tangent, curve and lateral. Rig up should be completed tomorrow with spud to follow.
1356231902 2017-02-07 Production Wells No Violations On the day of my inspection I witnessed the production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 2-26H, and Ripley 3-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 250 pounds per square inch on the tubing and 550 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
1364803740 2018-05-02 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. The production equipment consisted of eight 400 barrel tanks, one 50 barrel tank, a vapor recovery tower, two compressors, a vertical heater treater, a gas combustor, back-up flare stack, a horizontal line heater, a vertical separator, and a sand trap.
13743380 2017-7-25 0:00: PW No Violations 0.50
1400097731 2014-05-14 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Express Energy Services drilled a 32 inch diameter hole to the depth of 109 feet and ran 110 feet of 26 inch 102.63#/ft conductor pipe. Stingray Cementing was on site and gained circulation with 41bbls of fresh water. Stingray Cementing pumped 15bbls of gel, 10bbls of fresh water and cemented pipe with 236 sacks of class A cement. Good returns of 12bbls and cement stayed surface.
1401211335 2014-05-27 Drill / Deepen / Reopen No Violations On the day of my inspection Nomac Drilling Rig #257 is rigging up with plans to spud on Friday. I discussed upcoming casing program with Company Man Frank Bean. Site inspection revealed no violations.
1402244595 2014-06-08 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson UTI Drilling Rig #257 drilled a 12.25 inch diameter hole to the depth of 2084 feet and Franks Casing crew ran 2069 feet of 9.625 inch 36#/ft. J-55 Intermediate Casing. Stingray Cementing pumped 25bbls of gel, 10bbls of fresh water and cemented casing with 720 sacks of class A cement. Good returns of 20bbls plug was landed @ 814psi and pressured up to 1356psi for 5 minutes and the floats held. Cement stayed to surface.
1477875741 2020-10-22 0:00 PW No Violations 1.00
1655352432 2014-06-09 Drill / Deepen / Reopen No Violations On the day of my inspection accompanied by ODNR Inspector Brandon Trigg, I witnessed that Patterson UTI Drilling Rig #257 had performed their FIT test, drilled out their float equipment and was drilling an 8.75 inch diameter hole at the depth of 2262 feet.
1879914567 2015-01-12 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A.
2073491812 2016-09-06 Production Wells No Violations On the day of my inspection I witnessed that the location was gated and locked. The production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 2-26H, and Ripley 3-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 200 pounds per square inch the tubing and 500 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
2137550092 2019-02-14 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present with valves reading 0 pounds per square inch on the 13.375-inch diameter surface casing, and 300 pounds per square inch on the 9.625-inch diameter intermediate casing. The production equipment on pad consisted of four vertical separators, four sand traps, four horizontal indirect line heaters, one vertical heater treater, eight 400-barrel tanks, one 50-barrel tank, one vapor recovery tower, one gas combustor, and one flare stack. Identification was located on the wellhead.
954386798 2018-4-19 0:00: PW No Violations 0.20
955680054 2014-5-29 0:00: DD No Violations 3.00

For data sources see[9]

References