{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.02,"lon":-81.23,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Warren Township | |
Operator Name: DIVERSIFIED PRODUCTION LLC | |
Well Pad ID: | |
Farm/Lease Name: LULU WAGNER | |
License Status: Producing | |
License Date: 2013-04-30 | |
Spud Date: 2013-07-26 | |
Spud Drilling Contractor: G & L DRILLING | |
Final Drill Date: 2013-07-31 | |
Well Total Depth: 4530.00 ft | |
Configuration: Vertical | |
Latitude: 40.020000 | |
Longitude: -81.230000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-04-30 | Proposed Formations:BEREA-OHIO SHALE, Issued Date:4/30/2013, Expired Date:4/30/2015 12:00:00 PM, Drilling unit acres:175.91, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2013-07-31 | |
Change of Owner | 2014-02-06 | Operator changed from 79, OXFORD OIL to 9216, ECLIPSE RESOURCES-OHIO LLC |
Construction Permit Expires | 2015-04-30 | |
Change of Owner | 2016-08-02 | Operator changed from 9216, ECLIPSE RESOURCES-OHIO LLC to 8685, M & R INVESTMENTS OHIO LLC |
Record Last Modified | 2019-06-11 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-11-21 | FOAM | 15 | 580 Bbl | 0 | Producers Service Corporation | FOAM FRAC
75Q |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | ECLIPSE RESOURCES-OHIO LLC | 0.00 | 0.00 | 0 |
2014 | ECLIPSE RESOURCES-OHIO LLC | 0.00 | 0.00 | 365 |
2016 | M & R INVESTMENTS OHIO LLC | 10.00 | 0.00 | 365 |
2017 | M & R INVESTMENTS OHIO LLC | 0.00 | 0.00 | 0 |
2018 | M & R INVESTMENTS OHIO LLC | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | ECLIPSE RESOURCES-OHIO LLC | Brine | 1010 | 0 |
2014 | ECLIPSE RESOURCES-OHIO LLC | Brine | 12768 | 365 |
2016 | M & R INVESTMENTS OHIO LLC | Brine | 0 | 365 |
2017 | M & R INVESTMENTS OHIO LLC | Brine | 0 | 0 |
2018 | M & R INVESTMENTS OHIO LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1101225797 | 2017-1-6 0:00:0 | PW | No Violations | 1.00 |
-1247017324 | 2019-4-9 0:00:0 | PW | No Violations | 0.20 |
-1384482910 | 2016-9-9 0:00:0 | PW | No Violations | 1.00 |
-1822539992 | 2016-12-6 0:00: | PW | No Violations | 1.00 |
-1994810905 | 2017-6-5 0:00:0 | PW | No Violations | 1.50 |
-2003677926 | 2017-9-11 0:00: | PW | No Violations | 1.00 |
-377939106 | 2018-2-9 0:00:0 | PW | No Violations | 0.50 |
-421757300 | 2016-9-27 0:00: | PW | No Violations | 0.50 |
-915267576 | 2019-9-4 0:00:0 | PW | No Violations | 0.60 |
0377939106 | 2018-02-09 | Production Wells | No Violations | |
0421757300 | 2016-09-27 | Production Wells | No Violations | |
0816052716 | 2017-02-08 | Production Wells | No Violations | |
0858810996 | 2016-11-09 | Production Wells | No Violations | |
0969628552 | 2015-06-18 | Production Wells | No Violations | On the day of my inspection I witnessed that the production equipment included a 100bbl tank, a 30bbl brine tank, a vertical separator and a drip all within an earthen dike. The well was equipped with 7 inch casing, 4.5 inch casing, 4.5 inch gate valve which was closed. Salesline has not been installed. Well identification was present and the production records were current but did not meet the minimum production requirement. Call was made to Eclipse Conventional Production Superintendent requesting an update on status of said well. |
1101225797 | 2017-01-06 | Production Wells | No Violations | |
1201510221 | 2017-03-23 | Production Wells | No Violations | |
1247017324 | 2019-04-09 | Production Wells | No Violations | The purpose of my inspection was to follow up on compliance notice numbered -1470933141. The notice stated well shall be plugged. During my inspection the well was equipped with 7-inch diameter surface casing with a casing head and 4.5-inch diameter production casing with a gate valve in the closed position. The 100-barrel tank has been removed from the earthen dike since my last inspection. I will continue to work with MR Investments on resolving this violation. Accompanied by ODNR inspector Rick Brown. |
1335474361 | 2016-07-20 | Production Wells | No Violations | On the day of my inspection I witnessed that the production equipment included a 100 barrel tank, a 37 barrel polymer tank, a vertical separator and a drip all within an earthen dike. The well was equipped with 7 inch casing, 4.5 inch casing, 4.5 inch gate valve which was closed. No identification has been posted and no plan for the well has been received from the operator of record. |
1337905675 | 2015-04-01 | Production Wells | No Violations | On the day of my inspection I witnessed that the production equipment included a 100bbl tank, a 30bbl brine tank, a vertical separator and a drip all within an earthen dike. The well was equipped with 7 inch casing, 4.5 inch casing, 4.5 inch gate valve which was closed. Salesline has not been installed. Well identification was present and I placed phone call to EHS Supervisor Bruce Carpenter requesting an update on the well and Bruce stated that he would find out plans for the well and notify ODNR. |
1374866281 | 2013-07-26 | Casing String Witnessed | No Violations | I am on site today and witnessed that GNL Drilling LLC. drilled a 15 hole to the depth of 120 and set 104 of new 9.625 27#/ft. casing. The pit was constructed and lined with plastic to the flow ditch. Formation Cementing Services was on site gained circulation and cemented casing with 105 sacks of Class A cement with 100lbs of gel, 100lbs of accelerator and 60lbs of LCM. Had good returns and cement stayed to surface. |
1375161849 | 2013-07-30 | Drill / Deepen / Reopen | No Violations | I am on site today training with Mike Hartshorn and witnessed that G&L Drilling LLC. drilled a 8.875 hole to the depth of 1050 and set 1015 of new 7 17#/ft. casing. The pit was constructed and lined with plastic to the flow ditch. Universal Well Services was on site gained circulation and cemented casing with 160 sacks of Class A cement with 2% CaCl. Had good returns and cement stayed to surface. |
1384482910 | 2016-09-09 | Production Wells | No Violations | |
1470933141 | 2016-08-11 | Production Wells | Violations Noted | On the day of my inspection I witnessed that the production equipment included a 100 barrel tank, a 37 barrel polymer tank, a vertical separator and a drip all within an earthen dike. The well was equipped with 7 inch casing; 4.5 inch casing and a 4.5 inch gate valve which was closed reduced to a 2 inch valve and locked. A flowline was found near the wellhead not connected and the salesline has not been installed. Identification was present with the contact information being the last owner of record and reviewing the production records revealed no production reported for 2015 and zero oil and gas production reported for 2014 and 2013. The well owner/operator shall submit a written plugging schedule to Doug Bennett at 5880 Memory Road Zanesville, Ohio 43701-9553 within 30 days, per OAC 1501:9-11-05(B), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied. |
1522201825 | 2014-08-18 | Preliminary Restoration | No Violations | On the day of my inspection I witnessed that the production equipment included a 100bbl tank, a 30bbl brine tank, a vertical separator and a drip all within an earthen dike. The well was equipped with 7 inch casing, 4.5 inch casing, 4.5 inch gate valve which was closed. Salesline has not been installed. Well identification was present and the site passed preliminary restoration according ORC 1509.072A. |
1548701959 | 2019-01-28 | Production Wells | No Violations | The purpose of my inspection was to follow up on compliance notice numbered -1470933141. The notice stated well shall be plugged. During my inspection the well was equipped with 7-inch diameter surface casing with a casing head and 4.5-inch diameter production casing with a gate valve in the closed position. The 100-barrel tank has been removed from the earthen dike since my last inspection. I will continue to work with MR Investments on resolving this violation. |
1574875870 | 2019-11-27 0:00 | PW | No Violations | 0.50 |
1582556365 | 2020-2-24 0:00: | PW | No Violations | 0.30 |
1582559930 | 2020-2-24 0:00: | PW | No Violations | 0.50 |
1822539992 | 2016-12-06 | Production Wells | No Violations | |
1905442603 | 2017-07-11 | Production Wells | No Violations | |
1928185109 | 2017-10-16 | Production Wells | No Violations | |
1994810905 | 2017-06-05 | Production Wells | No Violations | |
2003677926 | 2017-09-11 | Production Wells | No Violations | |
2013643848 | 2018-04-09 | Production Wells | No Violations | The purpose of my inspection was to follow up on compliance notice numbered -1470933141. The notice stated that the well shall be plugged. During my inspection I witnessed that the well had not yet been hooked up to a sales line. The well was equipped with 7 inch diameter surface casing with a casing head and 4.5 inch diameter production casing with a gate valve in the closed position. I will continue to work with MR Investments on resolving this violation. |
2121050660 | 2018-08-07 | Production Wells | No Violations | The purpose of my inspection was to follow up on compliance notice numbered -1470933141. The notice was issued to M&R Investments stating that the well shall be plugged. During my inspection the well was equipped with 7-inch diameter surface casing with a casing head and 4.5-inch diameter production casing with a gate valve in the closed position. No lines were attached to the well. I will continue to work with MR Investments on resolving this violation. |
754265455 | 2020-5-4 0:00:0 | PW | No Violations | 1.00 |
816052716 | 2017-2-8 0:00:0 | PW | No Violations | 1.50 |
858810996 | 2016-11-9 0:00: | PW | No Violations | 1.00 |
969628552 | 2015-6-18 0:00: | PW | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1470933141 | US-OH-113534 | 2016-08-16 | Well shall be plugged |