X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24091

Well Details

Well ID: 34-059-24091
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Richland Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID:
Farm/Lease Name: HENDERSHOT/ROE UNIT
License Status: Final Restoration
License Date: 2018-05-17
Spud Date: 2008-11-27
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2008-12-12
Well Total Depth: 6006.00 ft
Configuration: Vertical
Latitude: 39.970000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-09-02 Proposed Formations:CLINTON/MEDINA, Issued Date:9/2/2008, Expired Date:9/2/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-12-12 GMM UPDATED PLUG STATUS PER PLUG REPORT
Completion Report Received 2009-07-13 GMM UPDATED PLUG STATUS PER PLUG REPORT
Change of Owner 2017-01-25 Operator changed from 490, DAVID R HILL INC to 8928, CARRIZO (UTICA) LLC
Change of Owner 2017-12-14 Operator changed from 8928, CARRIZO (UTICA) LLC to 9520, ASCENT RESOURCES UTICA LLC
APP 2018-05-17 Proposed Formations:CLINTON-MEDINA, Issued Date:5/17/2018, Expired Date:5/16/2020 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-06-18 GMM UPDATED PLUG STATUS PER PLUG REPORT
Record Last Modified 2018-10-31 GMM UPDATED PLUG STATUS PER PLUG REPORT
Construction Permit Expires 2020-05-16 GMM UPDATED PLUG STATUS PER PLUG REPORT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-10-02 5739 5829 70
2009-10-02 5874 5880 13
5739 5829 70
5874 5880 13
5739 5829 70

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 83873 Gal 40000 FRACED INTERVAL INCLUDED THE MEDINA SANDSTONE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 DAVID R HILL INC 5478.00 0.00 163
2010 DAVID R HILL INC 4372.00 49.00 365
2011 DAVID R HILL INC 2746.00 51.00 365
2012 DAVID R HILL INC 2037.00 69.00 366
2013 DAVID R HILL INC 1129.00 34.00 365
2014 DAVID R HILL INC 1509.00 0.00 365
2015 DAVID R HILL INC 1107.00 41.00 365
2016 DAVID R HILL INC 892.00 0.00 365
2017 CARRIZO (UTICA) LLC 245.00 0.00 0
2018 ASCENT RESOURCES UTICA LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 DAVID R HILL INC Brine 445 163
2010 DAVID R HILL INC Brine 330 365
2011 DAVID R HILL INC Brine 141 365
2012 DAVID R HILL INC Brine 108 366
2013 DAVID R HILL INC Brine 56 365
2014 DAVID R HILL INC Brine 215 365
2015 DAVID R HILL INC Brine 50 365
2016 DAVID R HILL INC Brine 0 365
2017 DAVID R HILL INC Brine 149 365
2018 ASCENT RESOURCES UTICA LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1239600726 2008-12-12 0:00 DD No Violations
-1449528049 2012-12-28 0:00 PW No Violations
-1682454333 2019-7-31 0:00: FR No Violations 0.60
-973327976 2018-1-29 0:00: PW No Violations 0.90
0523927395 2018-06-17 Plug / Plug Back No Violations KLX rigged up on location and perforated the 8.625 inch diameter surface casing with six shots each at 1453 feet, 1214 feet, 400 feet, and 200 feet. Unlimited tripped the 2.375 inch tubing into 1493 feet.
0530975808 2008-12-09 Drill / Deepen / Reopen No Violations KILBARGER DRILLING #17. DILLING AT 3809
0827379718 2012-12-28 Production Wells No Violations On the day of my inspection I found the divisions production records current, the pumping unit at the well site was running at the time of my inspection, there is (1) one hundred barrel production tank/ separator/ drip/ chart setting inside a containment dike, the I.D. is posted on the tank.
0897275496 2018-06-18 Plug / Plug Back No Violations Unlimited pumped a class A cement plug from 1493 feet to 1143 feet. The tubing was pulled up to 414 feet and a class A cement plug was pumped from 414 feet to surface. Cement circulation was established within the conductor and filled the 8.625 inch surface casing.
0944919358 2018-05-10 Production Wells Violations Noted
0973327976 2018-01-29 Production Wells No Violations On the day of my inspection I witnessed the production equipment included a 140 barrel tank, a 37 barrel plastic tank, a vertical separator, a drip, a 2 inch meter run with a .25 inch orifice and a chart recorder all within an earthen dike. The well was equipped with 8.625 inch diameter casing; 4.5 inch diameter casing, 2.375 inch diameter tubing, rods and an American pumping unit powered by electricity with valves closed on the tubing and closed on the casing. Identification was present and production records were current.
1227706149 2008-11-26 Drill / Deepen / Reopen No Violations WAREEN DRILLING #7. DRILLING AT 2480. PLAN TO DRILL TO 3300 AND SHUT DOWN FOR T-GIVING. ON EDGE OF COLUMBIA GAS STORAGE AREA. TO HAVE COLUMBIA GAS S PEOPLE OUT WHEN DRILLING COMMMENCES AFTER HOLIDAY.
1228850064 2008-12-08 Drill / Deepen / Reopen No Violations KILBARGER DRILLING #17. DRILLING AT 2054
1229038588 2008-12-11 Drill / Deepen / Reopen No Violations KILBARGER DRILLING#17, DRILLING AT 5633
1239600726 2008-12-12 Drill / Deepen / Reopen No Violations KILBARGER DRILLING #17. HOLE LOGGED AND RUNNING PIPE
1258577988 2009-11-16 Preliminary Restoration No Violations Inspection revealed that restoration work at site is satisfactory,pit has been filled in and site reclaimed and vegatation has been established. Well is equipped with pumping unit and tubing and rods and 1-100 bbl tank and 1-50 bbl water tank located within dike area.
1449528049 2012-12-28 Production Wells No Violations On the day of my inspection I found the divisions production records current, the valve on the production line is open, there are (2) one hundred barrel production tanks/ (2) plastic brine tanks/ (2) separators/ (2) drips/ (2) charts setting inside a containment dike, the I.D. is posted on the tank.
1527248653 2018-05-16 Production Wells No Violations During my inspection today the well continued to gas on the backside of the 8.625 inch diameter surface casing. There have not been any produced fluids released.
1528413559 2018-06-06 Production Wells No Violations The purpose of my inspection was a status check on plugging operations. Ascent Production Superintendent Adam Pence stated via email that Ascent planned to begin moving in to plug the well today. During my inspection the service company had not mobilized the rig to the location. Ascent well tenders were at the tank battery preparing to disassemble the equipment. I called Mr. Pence and asked him what his timeline was for mobilizing the rig and he stated that he would be rigging up on location this afternoon.
1528990691 2018-06-13 Plug / Plug Back No Violations Unlimited Energy Services was on location with their double pole service rig, cement pump truck, cement bulk truck, and water truck. Unlimited pumped a 400 foot bottom hole plug within the 4.5 inch casing from 5652 feet to 5252 feet with class A cement weighing 15.6 pound per gallon. The plug was displaced with 20 barrels of water. When the lines were disconnected from the tubing the well could be heard going on a vacuum. Unlimited pulled the tubing up out of the cement plug to 4652 feet. Unlimited waited on cement to cure and then tripped the tubing back down to tag the cement plug. The plug descended downhole past the reach of the tubing at 5652 feet. Unlimited pumped a 9 barrel gel pill and 30 sacks of class A cement with lost circulation material from 5652 feet to 5252 feet. the plan was to pump a 60 sack plug but due to pump truck complications we stopped pumping cement at 30 sacks and went into displacement with 20 barrels of fresh water. The tubing was tripped up out of the cement and the well was shut in overnight.
1529252069 2018-06-14 Plug / Plug Back No Violations Unlimited tripped the tubing down and tagged the cured cement plug at 5531 feet which was 208 feet above the top perforation within the 4.5 inch diameter production casing. Unlimited began to trip the tubing out of hole and KLX arrived on location. The rig experienced issues with the power tongs and breaking apart the tubing with pipe wrenches. Once the tubing was completely out of hole KLX ran a bond logon the 4.5 inch casing. A cave in was recorded at 1620 feet on the backside of the 4.5 inch casing. KLX shot the casing off at 4234 feet.
1530473514 2018-06-15 Plug / Plug Back No Violations Unlimited attempted to remove the 4.5 inch diameter casing from hole but could not do so. Unlimited began to pump water ahead of the big lime cement plug through the 4.5 inch casing and circulation was established inside the conductor. The conductor did not have any casing head to contain and control the circulation so Unlimited stopped pumping and shut down for the day to construct a lined earthen pit and a trench to the wellhead.
1534433991 2018-08-16 Final Restoration No Violations The purpose of my inspection was a status check on a final restoration. During my inspection the production equipment had been removed and the location had been graded. Once the vegetation is established the location will potentially meet requirements for final restoration. A follow up inspection will be conducted.
1649551234 2008-11-26 Drill / Deepen / Reopen No Violations KILBARGER DRILLING#17 RIGGED UP. BUT ARE WORKING ON RIG TODAY. TO DRILL CONDUCTOR HOLE AND SET CONDUCTOR PIPE THEN SHUT DOWN FOR DEER SEASON NEXT WEEK.
523927395 2018-6-17 0:00: PB No Violations 7.00
530975808 2008-12-9 0:00: DD No Violations
827379718 2012-12-28 0:00 PW No Violations
897275496 2018-6-18 0:00: PB No Violations 4.00
941631999 2018-5-10 0:00: PW No Violations 1.50
944919358 2018-5-10 0:00: PW No Violations 1.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0944919358 US-OH-130801 2018-05-24 9-9-02 General Safety
0944919358 US-OH-130802 2018-05-24 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas
0944919358 US-OH-130803 2018-05-24 NONE18 Defective casing, leaking well

For data sources see[9]

References