X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-22963

Well Details

Well ID: 34-059-22963
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Spencer Township
Operator Name: K PETROLEUM INC
Well Pad ID:
Farm/Lease Name: WALLER CLIFFORD
License Status: Producing
License Date: 1981-05-20
Spud Date: 1981-08-09
Spud Drilling Contractor:
Final Drill Date: 1981-08-15
Well Total Depth: 5540.00 ft
Configuration: Vertical
Latitude: 39.860000
Longitude: -81.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-05-20 3443 MALVERN GROUP INC GeoDate 5/20/81
Original Spud 1981-08-09 75.91=ACRES
Completed 1981-08-15 75.91=ACRES
Reached Total Depth 1981-08-15 75.91=ACRES
Change of Owner 2003-09-09 Operator changed from 3443, MALVERN GROUP INC to 7498, K PETROLEUM INC
Record Last Modified 2013-10-03 75.91=ACRES

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5386 5394 12
5386 5394 12
5386 5394 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DERBY OIL & GAS CORP 24116.00 0.00 0
1985 DERBY OIL & GAS CORP 12856.00 0.00 255
1986 DERBY OIL & GAS CORP 12001.00 0.00 262
1987 CHRISTA OIL CO 822934.00 0.00 224
1988 BAUGHMAN ELEANOR 7620.00 0.00 313
1989 BAUGHMAN ELEANOR 6557.00 0.00 317
1990 MALVERN GROUP INC 6164.00 28.00 356
1991 MALVERN GROUP INC 4573.00 34.00 332
1992 MALVERN GROUP INC 2714.00 56.00 280
1993 MALVERN GROUP INC 3664.00 0.00 365
1994 MALVERN GROUP INC 2030.00 0.00 365
1995 MALVERN GROUP INC 3250.00 0.00 335
1996 MALVERN GROUP INC 537.00 0.00 150
1997 MALVERN GROUP INC 56.00 0.00 120
1998 MALVERN GROUP INC 3738.00 0.00 365
1999 MALVERN GROUP INC 2573.00 0.00 365
2000 MALVERN GROUP INC 2890.00 0.00 315
2001 MALVERN GROUP INC 1066.00 0.00 365
2002 MALVERN GROUP INC 1900.00 0.00 290
2003 K PETROLEUM INC 1353.00 0.00 0
2004 K PETROLEUM INC 0.00 0.00 0
2005 K PETROLEUM INC 0.00 0.00 0
2006 K PETROLEUM INC 0.00 0.00 0
2007 K PETROLEUM INC 0.00 0.00 0
2008 K PETROLEUM INC 0.00 0.00 0
2009 K PETROLEUM INC 0.00 0.00 0
2010 K PETROLEUM INC 0.00 0.00 0
2012 K PETROLEUM INC 0.00 0.00 0
2014 K PETROLEUM INC 0.00 0.00 0
2015 K PETROLEUM INC 0.00 0.00 0
2016 K PETROLEUM INC 0.00 0.00 0
2017 K PETROLEUM INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DERBY OIL & GAS CORP Brine 215 0
1985 DERBY OIL & GAS CORP Brine 75 255
1986 DERBY OIL & GAS CORP Brine 79 262
1987 CHRISTA OIL CO Brine 141 224
1988 BAUGHMAN ELEANOR Brine 115 313
1989 BAUGHMAN ELEANOR Brine 89 317
1990 MALVERN GROUP INC Brine 49 356
1991 MALVERN GROUP INC Brine 153 332
1992 MALVERN GROUP INC Brine 75 280
1993 MALVERN GROUP INC Brine 140 365
1994 MALVERN GROUP INC Brine 40 365
1995 MALVERN GROUP INC Brine 0 335
1996 MALVERN GROUP INC Brine 0 150
1997 MALVERN GROUP INC Brine 120
1998 MALVERN GROUP INC Brine 60 365
1999 MALVERN GROUP INC Brine 365
2000 MALVERN GROUP INC Brine 315
2001 MALVERN GROUP INC Brine 320 365
2002 MALVERN GROUP INC Brine 0 290
2003 MALVERN GROUP INC Brine 0 182
2004 K PETROLEUM INC Brine 0 0
2005 K PETROLEUM INC Brine 0 0
2006 K PETROLEUM INC Brine 0 0
2007 K PETROLEUM INC Brine 0 0
2008 K PETROLEUM INC Brine 0 0
2009 K PETROLEUM INC Brine 0 0
2010 K PETROLEUM INC Brine 0 0
2012 K PETROLEUM INC Brine 0 0
2014 K PETROLEUM INC Brine 0 0
2015 K PETROLEUM INC Brine 0 0
2016 K PETROLEUM INC Brine 0 0
2017 K PETROLEUM INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1033840769 2007-8-29 0:00: PW No Violations
-1173816818 2020-9-21 0:00: PW No Violations 1.00
-1305011667 2018-2-1 0:00:0 PW No Violations 0.80
-1468899487 2015-11-30 0:00 PW No Violations 1.00
-1819588760 2015-2-2 0:00:0 PW No Violations 1.00
-265274364 2015-4-30 0:00: PW No Violations 1.00
-316288797 2017-6-13 0:00: PW No Violations 1.00
-415214177 2016-6-24 0:00: PW No Violations 1.00
-637511098 2019-3-20 0:00: PW No Violations 0.70
-712094673 2012-3-23 0:00: PW No Violations
-735975122 2020-5-27 0:00: PW No Violations 1.00
-935751066 2020-2-24 0:00: PW No Violations 0.50
0219363842 2017-02-01 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed there was no change in the status since the last inspection on December 13, 2016. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 2.375 inch diameter tubing, rods and a Churchill pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible.
0265274364 2015-04-30 Production Wells No Violations On the day of my inspection following up on NOV-1244742399 accompanied by ODNR Inspector Matt Fulk, I witnessed the well was equipped with 8.625 inch casing and 4.5 inch casing, 2.375 inch tubing, rods and a pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible. There was no change in the status of the said well.
0316288797 2017-06-13 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed there was no change in the status since the last inspection on March 30, 2017. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 2.375 inch diameter tubing, rods and a Churchill pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible.
0415214177 2016-06-24 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed there was no change in the status since the last inspection. The well was equipped with 8.625 inch casing and 4.5 inch casing, 2.375 inch tubing, rods and a Churchill pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible.
0637511098 2019-03-20 Production Wells No Violations The purpose of my inspection was to follow up on compliance notice numbered -1244742399. The compliance notice stated well shall be plugged. During my inspection the well was equipped with 8.625-inch diameter surface casing with a casing head with two ports open to the atmosphere with no bull plugs present, 4.5-inch diameter production casing with a tubing head with no lines attached, 1.5-inch diameter tubing, rods, and a pumping unit. The 1.5-inch tubing had a threaded on cross fitting with on line attached with a valve in the closed position. A blank identification sign tied onto the production flow line. K Petroleum submitted reports of zero production from the year 2004 to the year 2017 and the years 2011 and 2013 there were not any reports submitted to ODNR.
0712094673 2012-03-23 Production Wells No Violations FOLLOW UP TO NOV # 1244742399 Received request from landowner Jerry Waller to inspect well on property upon inspecting well found it incapable of producing in its present state of repair electric motor is missing from pumping unit and 1-100bbl tank is seeping on bottom seam and plastic water tank is cracked and leaking in dike area, no production has been reported on well in several years and previous inspector issued notice on well in 2007.

Plug well or file for temporary inactive status, replace tanks at site and clean up affected area and remove all unused equipment from site. Failure to comply may result in bond forfeiture.

1033840769 2007-08-29 Production Wells No Violations FOLLOW UP TO NOV # 1188395560 WELL IS IDLE ALL VALVES CLOSED, APPEARS NO ACTIVITY IN SEVERAL YEARS. APPEARS TO HAVE HOLE IN 4.
1188395560 2007-08-29 Production Wells Violations Noted WELL IS IDLE ALL VALVES CLOSED, APPEARS NO ACTIVITY IN SEVERAL YEARS. APPEARS TO HAVE HOLE IN 4.
1244742399 2012-03-23 Production Wells Violations Noted Received request from landowner Jerry Waller to inspect well on property upon inspecting well found it incapable of producing in its present state of repair electric motor is missing from pumping unit and 1-100bbl tank is seeping on bottom seam and plastic water tank is cracked and leaking in dike area, no production has been reported on well in several years and previous inspector issued notice on well in 2007.

Plug well or file for temporary inactive status, replace tanks at site and clean up affected area and remove all unused equipment from site. Failure to comply may result in bond forfeiture.

1305011667 2018-02-01 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed there was no change in the status since the last inspection on October 12, 2017. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, rods and a Churchill pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible.
1327379634 2019-8-14 0:00: PW No Violations 0.50
1336774153 2012-05-11 Production Wells No Violations Inspection revealed that production tank and separator has been removed from site and P&C violations have been resolved but well still remains idle owner stated that they were attempting to get gas contract for gas sales and once they have contract they will begin to produce well.
1381347915 2013-10-09 Production Wells No Violations On the day of my inspection I found no change to the status of the well from the last inspection done by Inspector David Ball, I placed a phone call to K- Petroleum to discuss the status of the well, my call went to voice mail, I left a message to return my call as soon as possible.
1468899487 2015-11-30 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed the well was equipped with 8.625 inch casing and 4.5 inch casing, 2.375 inch tubing, rods and a pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible. A letter was sent to K-Petroleum on May 4, 2015 requesting a detailed plan on bringing the well into compliance. A letter was received from K-Petroleum President on May 26, 2015 stating that the company may be able to sell gas through a meter located 1.4 miles away and that they were requesting temporary abandonment of well. A response dated A June 4, 2015 sent electronically stated that temporary inactivity status is processed through Columbus and a timeline was needed for review so that a possible extension could be granted. As of date no further communication has been received from K-Petroleum and the well remains incapable of production.
147248760 2020-2-24 0:00: PW No Violations 0.50
1481655032 2016-12-13 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed there was no change in the status since the last inspection on September 12, 2016. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 2.375 inch diameter tubing, rods and a Churchill pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible.
1515684614 2017-10-12 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed there was no change in the status since the last inspection on June 13, 2017. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, rods and a Churchill pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible.
1519171641 2012-03-23 Production Wells No Violations FOLLOW UP TO NOV # 1244742399 Received request from landowner Jerry Waller to inspect well on property upon inspecting well found it incapable of producing in its present state of repair electric motor is missing from pumping unit and 1-100bbl tank is seeping on bottom seam and plastic water tank is cracked and leaking in dike area, no production has been reported on well in several years and previous inspector issued notice on well in 2007.

Plug well or file for temporary inactive status, replace tanks at site and clean up affected area and remove all unused equipment from site. Failure to comply may result in bond forfeiture.

1538570128 2018-10-02 Production Wells No Violations The purpose of my inspection was to follow up on compliance notice number -1244742399. The compliance notice stated well shall be plugged. During my inspection the well was equipped with 8.625-inch diameter surface casing with a casing head, 4.5-inch diameter production casing with a tubing head, 1.5-inch diameter tubing, rods, and a pumping unit. There were not any lines attached to the production casing and the lines attached to the production tubing were in the closed position. A blank identification sign was attached to the wellhead. Production equipment for the well could not be located. K Petroleum submitted reports of zero production from the year 2004 to the year 2017 and the years 2011 and 2013 there were not any reports submitted to ODNR.
1574781442 2019-11-26 0:00 PW No Violations 0.50
1585077901 2020-3-24 0:00: PW No Violations 1.00
1819588760 2015-02-02 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed the well was equipped with 8.625 inch casing and 4.5 inch casing, 2.375 inch tubing, rods and a pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and no identification was present but not legible. I placed call to K Petroleum and advised them that I needed an update on said well.
1918869957 2017-03-30 Production Wells No Violations On the day of my inspection following up on NOV-1244742399, I witnessed there was no change in the status since the last inspection on February 1, 2017. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 2.375 inch diameter tubing, rods and a Churchill pumping unit powered by electricity with no motor present with valves in the closed position. No production equipment was found and identification was present but not legible.
219363842 2017-2-1 0:00:0 PW No Violations 1.00
81872540 2019-8-14 0:00: PW No Violations 0.60

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1188395560 US-OH-105007 2007-08-29 Well shall be plugged
1244742399 US-OH-106533 2012-03-24 Well operation causing pollution and contamination
1244742399 US-OH-106534 2012-03-24 No SPCC dike/or failure to keep dike free of water or oil
1244742399 US-OH-106535 2012-03-24 Well shall be plugged
1244742399 US-OH-106536 2012-03-24 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[9]

References