X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-22925

Well Details

Well ID: 34-059-22925
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Spencer Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: DICKERSON JOHN
License Status: Producing
License Date: 1981-12-07
Spud Date: 1981-12-12
Spud Drilling Contractor:
Final Drill Date: 1981-12-17
Well Total Depth: 5054.00 ft
Configuration: Vertical
Latitude: 39.890000
Longitude: -81.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-12-07 3443 MALVERN GROUP INC GeoDate 12/7/81
Original Spud 1981-12-12
Completed 1981-12-17
Reached Total Depth 1981-12-17
Change of Owner 2000-02-14 Operator changed from 3443, MALVERN GROUP INC to 6351, T & C OIL & GAS COMPANY
Change of Owner 2002-06-24 Operator changed from 6351, T & C OIL & GAS COMPANY to 2948, CRUM ROBERT L
Change of Owner 2003-02-03 Operator changed from 2948, CRUM ROBERT L to 952, G-R CONTRACTING INC
Change of Owner 2013-05-20 Operator changed from 952, G-R CONTRACTING INC to 1333, BIG SKY ENERGY INC
Change of Owner 2017-11-08 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2019-06-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4865 4874 12
4865 4874 12
4865 4874 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1800 Bbl 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DERBY OIL & GAS CORP 2505.00 523.00 0
1985 DERBY OIL & GAS CORP 2309.00 417.00 162
1986 DERBY OIL & GAS CORP 2805.00 255.00 365
1987 CHRISTA OIL CO 2230.00 459.00 206
1988 BAUGHMAN ELEANOR 2743.00 248.00 301
1989 BAUGHMAN ELEANOR 2010.00 364.00 302
1990 MALVERN GROUP INC 2361.00 373.00 347
1991 MAJESTIC OIL & GAS INC 2117.00 239.00 336
1992 MALVERN GROUP INC 2281.00 233.00 365
1993 MALVERN GROUP INC 682.00 154.00 365
1994 MALVERN GROUP INC 749.00 231.00 365
1995 MALVERN GROUP INC 0.00 131.00 365
1996 MALVERN GROUP INC 0.00 85.00 335
1997 MALVERN GROUP INC 0.00 140.00 185
1998 MALVERN GROUP INC 0.00 147.00 365
1999 MALVERN GROUP INC 0.00 148.00 365
2000 MALVERN GROUP INC 0.00 0.00 60
2001 T & C OIL & GAS COMPANY 1534.00 57.00 350
2002 G-R CONTRACTING INC 0.00 0.00 365
2005 G-R CONTRACTING INC 1242.00 0.00 365
2006 G-R CONTRACTING INC 3164.00 171.00 365
2007 G-R CONTRACTING INC 1245.00 102.00 365
2008 G-R CONTRACTING INC 1852.00 73.00 365
2009 G-R CONTRACTING INC 1152.00 175.00 365
2010 G-R CONTRACTING INC 1997.00 78.00 365
2011 G-R CONTRACTING INC 891.00 129.00 365
2012 G-R CONTRACTING INC 2016.00 74.00 366
2013 G-R CONTRACTING INC 0.00 0.00 120
2014 G-R CONTRACTING INC 71.00 0.00 30
2016 BIG SKY ENERGY INC 157.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DERBY OIL & GAS CORP Brine 92 0
1985 DERBY OIL & GAS CORP Brine 217 162
1986 DERBY OIL & GAS CORP Brine 4150 365
1987 CHRISTA OIL CO Brine 240 206
1988 BAUGHMAN ELEANOR Brine 266 301
1989 BAUGHMAN ELEANOR Brine 90 302
1990 MALVERN GROUP INC Brine 12 347
1991 MAJESTIC OIL & GAS INC Brine 11 336
1992 MALVERN GROUP INC Brine 0 365
1993 MALVERN GROUP INC Brine 0 365
1994 MALVERN GROUP INC Brine 0 365
1995 MALVERN GROUP INC Brine 0 365
1996 MALVERN GROUP INC Brine 0 335
1997 MALVERN GROUP INC Brine 185
1998 MALVERN GROUP INC Brine 365
1999 MALVERN GROUP INC Brine 365
2000 MALVERN GROUP INC Brine 60
2001 T & C OIL & GAS COMPANY Brine 0 350
2002 G-R CONTRACTING INC Brine 0 365
2005 G-R CONTRACTING INC Brine 0 365
2006 G-R CONTRACTING INC Brine 0 365
2007 G-R CONTRACTING INC Brine 0 365
2008 G-R CONTRACTING INC Brine 0 365
2009 G-R CONTRACTING INC Brine 0 365
2010 G-R CONTRACTING INC Brine 0 365
2011 G-R CONTRACTING INC Brine 0 365
2012 G-R CONTRACTING INC Brine 0 366
2013 G-R CONTRACTING INC Brine 0 120
2014 G-R CONTRACTING INC Brine 0 30
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1227817760 2017-8-4 0:00:0 PW No Violations 1.00
-259499744 2004-9-29 0:00: PW No Violations
-343362350 2016-9-13 0:00: PW No Violations 1.00
-545737116 2016-4-1 0:00:0 PW No Violations 1.50
-86432901 2014-3-25 0:00: PW No Violations 1.50
0086432901 2014-03-25 Production Wells No Violations

-43 and NOV-1393254322, I witnessed that at the entry of the lease road a compressor unit was present with a drip and a polymer condensate tank all valves were in the open position and the power was in the auto position. The tank battery consisted of 2-100bbl tanks, a horizontal separator, a drip, 2 inch meter run with no orifice or chart recorder all valves were open on the flow line and sales line. The well was capable of production and was pumping while I was on location. The well was equipped with 4.5 inch casing, 1.5 inch tubing, rods, a pumping unit powered electrically, domestic gas service, with all the valves were in the open position, the power in the auto position and the power at the main pole was in the on position. Production records were current and identification was present and has been corrected. Well remains in production.

0259499744 2004-09-29 Production Wells No Violations STATUS CHECK, DIKE AREA RECENTLY RE-WORKED
0343362350 2016-09-13 Production Wells No Violations

--105, I witnessed that at the entry of the lease road a compressor unit was present with a drip and a polymer condensate tank all valves were in the closed position and the power was in the off position. The production equipment included 2-100 barrel tanks, a horizontal separator and a drip. The well was equipped with 4.5 inch casing, 1.5 inch tubing, rods, a Churchill pumping unit powered electrically and domestic gas service with one valve open supplying the domestic gas and all other valves in the closed position. Identification is present and production records were current. There was no gas flowing through the master meter which has the same reading as the last inspection on 4/19/16 of 6278.

0545737116 2016-04-01 Production Wells No Violations

-105, I witnessed that at the entry of the lease road a compressor unit was present with a drip and a polymer condensate tank all valves were in the open position and the power was in the auto position. The production equipment included 2-100bbl tanks, a horizontal separator and a drip. Gas was flowing through a meter located east of the tank battery going into a Gatherco sales line. The well was equipped with 4.5 inch casing, 1.5 inch tubing, rods, a Churchill pumping unit powered electrically and domestic gas service with all the valves in the open position. A 3 foot by 6 foot diameter of contamination was present around well head where the stuffing box was leaking. Identification is present and production records were current. Big Sky Well Tender Greg Henderson arrived on location and he repaired stuffing box and removed contamination around wellhead.

0566937008 2007-05-16 Production Wells No Violations PRODUCING WELL
1184684040 2007-07-16 Production Wells No Violations STATUS CHECK
1227817760 2017-08-04 Production Wells No Violations

--105, I witnessed that at the entry of the lease road a compressor unit was present with a drip and a polymer condensate tank all valves were in the closed position and the power was in the off position. The production equipment found in heavy vegetation included 2-100 barrel tanks, a horizontal separator and a drip. The well was equipped with 4.5 inch diameter casing, 1.5 inch diameter tubing, rods, a Churchill pumping unit powered electrically and domestic gas service with one valve open supplying the domestic gas and all other valves in the closed position. Identification is present and production records were not current. There was no gas flowing through the Aspire master meter which has the same reading as the inspection on 4/19/16 of 6278.

1287082051 2016-04-18 Production Wells No Violations

--105, I witnessed that at the entry of the lease road a compressor unit was present with a drip and a polymer condensate tank all valves were in the open position and the power was in the auto position. The production equipment included 2-100bbl tanks, a horizontal separator and a drip. Gas was flowing through a meter located east of the tank battery going into a Gatherco sales line. The well was equipped with 4.5 inch casing, 1.5 inch tubing, rods, a Churchill pumping unit powered electrically and domestic gas service with all the valves in the open position. The stuffing box has been repaired and contamination remediated with a small amount of seepage present. Identification is present and production records were current.

1289i54512 2001-04-02 Production Wells No Violations no violatins noted
1289i5451218 2001-4-2 0:00:0 PW No Violations
1393254322 2014-02-24 Production Wells Violations Noted On the day of my inspection I witnessed that at the entry of the lease road a compressor unit was present with a drip and a polymer condensate tank all valves were in the open position and the power was in the auto position. The tank battery consisted of 2-100bbl tanks, a horizontal separator, a drip, 2 inch meter run with no orifice or chart recorder all valves were open on the flow line and sales line. The well was capable of production and was pumping while I was on location. The well was equipped with 4.5 inch casing, 1.5 inch tubing, rods, a pumping unit powered electrically, domestic gas service, with all the valves were in the open position, the power in the auto position and the power at the main pole was in the on position. Production records were current and identification was present at the well and the tank battery however the company and phone numbers were incorrect. Found meter with gas flowing through to a Gatherco Inc. line. I then called and spoke to Nicole at Gatherco Inc. and she stated that the meter was registered to G-
1509208501 2016-04-19 Production Wells No Violations

--105, I witnessed that at the entry of the lease road a compressor unit was present with a drip and a polymer condensate tank all valves were in the closed position and the power was in the off position. The production equipment included 2-100bbl tanks, a horizontal separator and a drip. The well was equipped with 4.5 inch casing, 1.5 inch tubing, rods, a Churchill pumping unit powered electrically and domestic gas service with one valve open supplying the domestic gas and all other valves in the closed position. Identification is present and production records were current.

1985841057 2008-04-21 Production Wells No Violations WELL STILL IN PRODUCTION
2007654748 2014-04-28 Production Wells No Violations

-43, I witnessed that at the entry of the lease road a compressor unit was present with a drip and a polymer condensate tank all valves were in the open position and the power was in the auto position. The tank battery consisted of 2-100bbl tanks, a horizontal separator and a drip. Gas was flowing through a meter located east of the tank battery going into a Gatherco sales line. The well was capable of production and was pumping while I was on location. The well was equipped with 4.5 inch casing, 1.5 inch tubing, rods, a pumping unit powered electrically, domestic gas service, with all the valves were in the open position, the power in the auto position and the power at the main pole was in the on position. Identification is present and production records are current through 2012.

566937008 2007-5-16 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1393254322 US-OH-111612 2014-04-10 Failure to legibly identify well

For data sources see[9]

References