Well Details

Well ID: 34-059-22228
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Jackson Township
Operator Name: HOPCO RESOURCES INC
Well Pad ID:
Farm/Lease Name: NICHOLSON-THORIA
License Status: Producing
License Date: 1977-10-17
Spud Date: 1978-02-14
Spud Drilling Contractor:
Final Drill Date: 1978-02-19
Well Total Depth: 5650.00 ft
Configuration: Vertical
Latitude: 39.970000
Longitude: -81.500000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1977-10-17 182 BELDEN & BLAKE CO GeoDate 10/17/77
Original Spud 1978-02-14
Completed 1978-02-19
Reached Total Depth 1978-02-19
Change of Owner 2002-08-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC
Change of Owner 2008-06-04 Operator changed from 1966, PETROX, INC to 8373, ROULETTE ENERGY LLC
Change of Owner 2008-11-03 Operator changed from 8373, ROULETTE ENERGY LLC to 7681, B & B OIL-N-GAS LLC
Change of Owner 2010-05-06 Operator changed from 7681, B & B OIL-N-GAS LLC to 1634, NORTHWOOD ENERGY CORP
Change of Owner 2018-04-25 Operator changed from 1634, NORTHWOOD ENERGY CORP to 37, HOPCO RESOURCES INC
Record Last Modified 2018-04-25

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5467 5501 2
5467 5501 2
5467 5501 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 ENTERPRISE ENERGY CORP 2313.00 0.00 0
1985 ENTERPRISE ENERGY CORP 1689.00 0.00 161
1986 BELDEN & BLAKE CORPORATION 4026.00 0.00 365
1987 BELDEN & BLAKE CORPORATION 2261.00 0.00 365
1988 BELDEN & BLAKE CORPORATION 2579.00 0.00 317
1990 BELDEN & BLAKE CORPORATION 1996.00 0.00 317
1991 BELDEN & BLAKE CORPORATION 1111.00 0.00 365
1992 BELDEN & BLAKE CORPORATION 760.00 0.00 256
1993 BELDEN & BLAKE CORPORATION 27.00 0.00 63
1994 BELDEN & BLAKE CORPORATION 983.00 0.00 268
1995 BELDEN & BLAKE CORPORATION 718.00 0.00 219
1996 BELDEN & BLAKE CORPORATION 803.00 0.00 358
1997 BELDEN & BLAKE CORPORATION 1138.00 0.00 346
1998 BELDEN & BLAKE CORPORATION 594.00 0.00 359
1999 BELDEN & BLAKE CORPORATION 413.00 0.00 321
2000 BELDEN & BLAKE CORPORATION 419.00 0.00 306
2001 BELDEN & BLAKE CORPORATION 256.00 0.00 222
2002 PETROX, INC 142.00 23.00 59
2003 PETROX, INC 235.00 0.00 365
2004 PETROX, INC 97.00 0.00 365
2005 PETROX, INC 0.00 0.00 0
2006 PETROX, INC 0.00 0.00 0
2007 PETROX, INC 0.00 0.00 0
2008 PETROX, INC 0.00 0.00 0
2010 NORTHWOOD ENERGY CORP 350.00 0.00 365
2011 NORTHWOOD ENERGY CORP 974.00 0.00 0
2012 NORTHWOOD ENERGY CORP 450.00 0.00 366
2013 NORTHWOOD ENERGY CORP 136.00 0.00 365
2014 NORTHWOOD ENERGY CORP 328.00 0.00 365
2015 NORTHWOOD ENERGY CORP 453.00 0.00 365
2016 NORTHWOOD ENERGY CORP 574.00 0.00 365
2017 NORTHWOOD ENERGY CORP 158.00 0.00 365
2018 HOPCO RESOURCES INC 81.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 ENTERPRISE ENERGY CORP Brine 50 0
1985 ENTERPRISE ENERGY CORP Brine 0 161
1986 BELDEN & BLAKE CORPORATION Brine 17 365
1987 BELDEN & BLAKE CORPORATION Brine 33 365
1988 BELDEN & BLAKE CORPORATION Brine 33 317
1990 BELDEN & BLAKE CORPORATION Brine 45 317
1991 BELDEN & BLAKE CORPORATION Brine 22 365
1992 BELDEN & BLAKE CORPORATION Brine 13 256
1993 BELDEN & BLAKE CORPORATION Brine 0 63
1994 BELDEN & BLAKE CORPORATION Brine 0 268
1995 BELDEN & BLAKE CORPORATION Brine 12 219
1996 BELDEN & BLAKE CORPORATION Brine 0 358
1997 BELDEN & BLAKE CORPORATION Brine 0 346
1998 BELDEN & BLAKE CORPORATION Brine 0 359
1999 BELDEN & BLAKE CORPORATION Brine 0 321
2000 BELDEN & BLAKE CORPORATION Brine 0 306
2001 BELDEN & BLAKE CORPORATION Brine 0 222
2002 BELDEN & BLAKE CORPORATION Brine 0 0
2003 PETROX, INC Brine 0 365
2004 PETROX, INC Brine 0 365
2005 PETROX, INC Brine 0 0
2006 PETROX, INC Brine 0 0
2007 PETROX, INC Brine 0
2008 PETROX, INC Brine 0 0
2010 NORTHWOOD ENERGY CORP Brine 0 365
2011 NORTHWOOD ENERGY CORP Brine 0
2012 NORTHWOOD ENERGY CORP Brine 0 366
2013 NORTHWOOD ENERGY CORP Brine 0 365
2014 NORTHWOOD ENERGY CORP Brine 0 365
2015 NORTHWOOD ENERGY CORP Brine 0 365
2016 NORTHWOOD ENERGY CORP Brine 0 365
2017 NORTHWOOD ENERGY CORP Brine 0 365
2018 HOPCO RESOURCES INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1757856044 2007-5-29 0:00: PW No Violations
-1990861593 2011-1-31 0:00: PW No Violations
-385492143 2018-5-15 0:00: PW No Violations 0.50
-628925627 2012-12-27 0:00 PW No Violations
0385492143 2018-05-15 Production Wells No Violations On 5/7/18 inspection found that a 2 inch diameter sales line was leaking natural gas 10 feet from the wellhead. I contacted Hopco Resources today to confirm that the successfully stopped the natural gas leak. Mr. Hopco stated that he found the leak and shut the well in to allow for him to make line repairs as needed. During my inspection today I found that the line was no longer leaking.
0559439920 2018-05-07 Production Wells No Violations The purpose of my inspection was to locate a gas line leak. Mark Pattison with Columbia Gas contacted me about the leak. Columbia Gas was initially called out to the leak but the line does not belong to Columbia Gas. The line belongs to Hopco Resources. I called Gary with Hopco at 7:30 a.m. and notified them of their line leak. Hopco stated that they could be there to shut the line in sometime this evening. During my inspection at 1:30 p.m. a horizontal separator was located at the entry of the lease road. A black 2 inch diameter plastic line was connected to the separator. The line ran on top of the ground beside the lease road back to the well. I followed the line back to the well and found that there was a 6 inch slice in the line. The damaged portion of the line was located 10 feet from the wellhead. The identification stated Northwood Energy. Hopco Resources obtained the well on 4/25/2018 and they will be granted 60 days to properly identify the well.
0628925627 2012-12-27 Production Wells No Violations On the day of my inspection I found the production records for the year of 2011 to be current, there is no pumping unit at the well site, the valve on the production line is closed, there is a plastic brine tank at the well site, the separator and the chart are setting by the entry way of the lease road, the chart is not current. I made a phone call to Northwood Energy to find out what problems the well is having and what steps are being taken to get the well back in production, I have not got a response back at this time.
1038040772 2019-04-11 Production Wells Violations Noted The purpose of my inspection was a status check. During my inspection the well was equipped with 4.5-inch diameter production casing with a 4.5-inch to 2-inch diameter swage nipple with a 2-inch production flow line attached. The production casing had a casing valve in the closed position and the flow line had a valve in the closed position. The production equipment consisted of one horizontal separator and one sales meter. The sales meter had a 2-inch diameter sales line, a .125-inch orifice plate, and a chart recorder with no chart. The production records were current with the prior owner Northwood Energy submitting reports of gas production for the year 2017. On 4/25/2018 Hopco Resources acquired the well from Northwood Energy. The identification was not in a conspicuous on or near the well head or production equipment. I called Gary Hopkins with Hopco Resources and he stated that he was getting identifications made for multiple wells owned by Hopco and that he will have the identification posted as soon as he is in the area. Mr. Hopkins will notify when the identification is posted.
1497676981 2019-05-07 Production Wells No Violations The purpose of my inspection was a follow up on a compliance notice. The notice was written for failure to legibly identify. During my inspection the identification remained absent. I will contact Gary Hopkins with Hopco Resources and remind him that identification needs to be posted.
1688166852 2019-4-11 0:00: PW No Violations 1.10
1757856044 2007-05-29 Production Wells No Violations STATUS CHECK
1758547883 2018-01-04 Production Wells No Violations On the day of my inspection with the ground snow covered, I witnessed the production equipment included a horizontal separator, a drip, a 2 inch meter run with a .125 inch orifice and a chart recorder all within an earthen dike. The well was equipped with 8.625 inch diameter casing 4.5 inch diameter casing reduced to a 2 inch flowline and domestic gas service with valves open on the casing and closed to the domestic gas. Identification was present and production records were current.
1990861593 2011-01-31 Production Wells No Violations Inspection revealed that well is being used for domestic purposes and is online, well is equipped with 4.5 casing and 1.5 tubing and 1-50 bbl plastic tank and separator and meter run located along Conquer Hill road.
479082655 2020-1-22 0:00: PW No Violations 0.50
559439920 2018-5-7 0:00:0 PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1038040772 US-OH-100357 2019-04-23 Failure to legibly identify well

For data sources see[9]

References