34-059-21748

Well Details

Well ID: 34-059-21748
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Londonderry Township
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: McELHANEY JOHN
License Status: Final Restoration
License Date: 2015-09-09
Spud Date: 1974-10-19
Spud Drilling Contractor:
Final Drill Date: 1974-10-29
Well Total Depth: 6013.00 ft
Configuration: Vertical
Latitude: 40.130000
Longitude: -81.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1973-11-29 2543 TIPKA ENERGY DEVLOP CO GeoDate 11/29/73
Original Spud 1974-10-19 R.I. 9-11-74 , CAN NOT SEE THE REST OF THE LOG TYPES I.P. NONE RPT.
Completed 1974-10-29 R.I. 9-11-74 , CAN NOT SEE THE REST OF THE LOG TYPES I.P. NONE RPT.
Reached Total Depth 1974-10-29 R.I. 9-11-74 , CAN NOT SEE THE REST OF THE LOG TYPES I.P. NONE RPT.
Change of Owner 2002-06-10 Operator changed from 2543, TIPKA ENERGY DEVLOP CO to 7219, DIMPLE ROCK DEVELOPMENT
Change of Owner 2006-12-29 Operator changed from 7219, DIMPLE ROCK DEVELOPMENT to 4327, SOUND ENERGY CO INC
APP 2015-09-09 Proposed Formations:CLINTON, Issued Date:9/9/2015, Expired Date:9/8/2017 12:00:00 PM, Drilling unit acres:91.8, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2015-11-02 R.I. 9-11-74 , CAN NOT SEE THE REST OF THE LOG TYPES I.P. NONE RPT.
Record Last Modified 2017-02-10 R.I. 9-11-74 , CAN NOT SEE THE REST OF THE LOG TYPES I.P. NONE RPT.
Construction Permit Expires 2017-09-08 R.I. 9-11-74 , CAN NOT SEE THE REST OF THE LOG TYPES I.P. NONE RPT.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 RESOURCE AMERICA INC 0.00 0.00 365
1985 RESOURCE AMERICA INC 0.00 0.00 365
1989 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 365
1990 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 365
1991 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
1992 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 365
1993 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
1994 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
1995 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
1996 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
1997 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
1998 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
1999 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
2000 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
2001 TIPKA ENERGY DEVLOPMENT COMPAN 0.00 0.00 0
2003 DIMPLE ROCK DEVELOPMENT 0.00 0.00 365
2004 DIMPLE ROCK DEVELOPMENT 0.00 0.00 365
2005 DIMPLE ROCK DEVELOPMENT 0.00 0.00 365
2006 SOUND ENERGY CO INC 0.00 0.00 365
2007 SOUND ENERGY CO INC 0.00 0.00 365
2008 SOUND ENERGY CO INC 0.00 0.00 365
2009 SOUND ENERGY CO INC 0.00 0.00 365
2010 SOUND ENERGY CO INC 0.00 0.00 365
2011 SOUND ENERGY CO INC 0.00 0.00 365
2012 SOUND ENERGY CO INC 0.00 0.00 366
2013 SOUND ENERGY CO INC 0.00 0.00 365
2014 SOUND ENERGY CO INC 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 RESOURCE AMERICA INC Brine 0 365
1985 RESOURCE AMERICA INC Brine 0 365
1989 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 365
1990 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 365
1991 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
1992 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 365
1993 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
1994 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
1995 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
1996 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
1997 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
1998 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
1999 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
2000 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
2001 TIPKA ENERGY DEVLOPMENT COMPAN Brine 0 0
2003 DIMPLE ROCK DEVELOPMENT Brine 0 365
2004 DIMPLE ROCK DEVELOPMENT Brine 0 365
2005 DIMPLE ROCK DEVELOPMENT Brine 0 365
2006 SOUND ENERGY CO INC Brine 0 365
2007 SOUND ENERGY CO INC Brine 0 365
2008 SOUND ENERGY CO INC Brine 0 365
2009 SOUND ENERGY CO INC Brine 0 365
2010 SOUND ENERGY CO INC Brine 0 365
2011 SOUND ENERGY CO INC Brine 0 365
2012 SOUND ENERGY CO INC Brine 0 366
2013 SOUND ENERGY CO INC Brine 0 365
2014 SOUND ENERGY CO INC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1089528241 2016-6-8 0:00:0 FR No Violations 1.00
-111880666 2006-9-1 0:00:0 PW No Violations
-1695825700 2015-11-3 0:00: AM No Violations
-1890731852 2015-10-27 0:00 PB No Violations 3.50
-19688973 2015-10-29 0:00 PB No Violations 4.50
-2078349957 2015-9-28 0:00: PW No Violations 1.00
-569312840 2015-10-30 0:00 PB No Violations 5.00
0019688973 2015-10-29 Plug / Plug Back No Violations On the day of my inspection following up NOV-1361899803, I witnessed Berry Well Service had tripped 1.5 inch tubing and sat down at 5850 feet and pulled up to 5836 feet. Petroset Cementing Services was on site and gained circulation and pumped a 30 sack 400 foot bottom plug from 5836 feet to 5436 feet. Cement was displaced with 13.7bbls of salt water. BWS tripped tubing to 4292 feet and Petroset gained circulation and pumped a 50 sack 200 foot Big Lime plug from 4292 feet to 4092 feet. Cement was displaced with 10.3bbls of salt water. BWS will tag plug tomorrow and rip 4.5 casing.
0111880666 2006-09-01 Production Wells No Violations PRODUCING WELL.
0560908775 2015-01-26 Production Wells No Violations On the day of my inspection following up NOV-1361899803, I witnessed the well was equipped with 8.625 inch casing, 4.5 inch casing with a 4.5 inch to 2 inch swedge with the valve in the closed position. Production equipment included a 100bbl tank in an earthen dike with identification present on the tank. I made a call to Bruce Levengood of Sound Energy requesting an update on the well. He stated that the well had never been completed and a bond log and casing test had been performed. Sound Energy plans on fracing well this summer.
0569312840 2015-10-30 Plug / Plug Back No Violations On the day of my inspection I witnessed Berry Well Service trip inside the 4.5 inch casing and tag the Big Lime plug at 3844 feet. BWS tripped 1.5 inch tubing out and ripped 4.5 inch casing at 2190 feet. BWS will trip out 4.5 inch casing and trip 1.5 inch tubing back in and set Rip plug on Monday and plug remainder of well.
1059740939 2015-06-30 Production Wells No Violations On the day of my inspection following up NOV-1361899803, I met with Sound Energy Representatives Chuck Baker and Mike Demattio and discussed their plan for testing casing integrity. Instructions were given to pressure up casing to a minimum of 1200psi in accordance with OAC 1501:9-1-08 (D)3(a). J Hawk Water Services was on site and loaded casing with fresh water and then proceeded to pressure up on casing. During the pressure test the casing well began circulating out the 8.625 casing valve. Discussion was held after failure of casing and the Sound Energy Representatives were instructed to apply for a plugging permit for said well per our earlier communications and discussions.
1089528241 2016-06-08 Final Restoration No Violations On the day of my inspection I witnessed that the site passed final restoration according to ORC 1509.072B.
1131552943 2005-11-09 Production Wells No Violations STATUS CHECK
1289i26153 2001-05-31 Production Wells No Violations STATUS CHECK
1289i26153843 2001-5-31 0:00: PW No Violations
1337882248 2013-10-24 Production Wells No Violations On the day of my inspection, I found no change in the status of the well since my last inspection done on 05/26/2013, I placed a phone call to Bruce Levengood with Sound Energy for an up date on a service rig availability to plug.
1361899803 2013-02-25 Production Wells No Violations On the day of my inspection I reviewed the Divisions production records and found there had been no production recorded from the year of 1984 to 2013, after speaking with Sound Energy I was told the well had never been produced. My inspection at the well site reveled eight inch casing with four inch production casing that had been broken off, there is (1) one hundred barrel production tank sitting on the well location. The requirements to meet the Divisions standards will be, to make the well capable of commercial production within sixty days, or plugging is required within sixty days, legibly identify well.
1367261754 2013-04-29 Production Wells No Violations No change in the status of the well, Sound Energy requested a sixty day extension for plugging and they are currently working with the landowner to resolve the lease issue.
1374688706 2015-08-10 Production Wells No Violations On the day of my inspection following up NOV-1361899803, I witnessed there was no change in the status of the well since casing integrity test was performed on 6/30/15. I spoke with Bruce Levengood of Sound Energy and he stated that the well was on their plug list and ODNR should receive their application soon.
1379520580 2013-09-17 Production Wells No Violations Pryor to my inspection, I made a phone call to Sound Energy and spoke with Bruce Levengood about the status and condition of the this well, Mr. Levengood asked me for a sixty day allowance to get a service rig on site and run a bond log to find out if the integrity of the 4.5 casing is any good before plugging, I agreed to the sixty day allowance, I also asked Mr. Levengood if he would take care of the one hundred barrel tank that is on site as well as fencing of the well head. The status of the well has not change since my last inspection.
1383148410 2013-10-30 Non Well No Violations On the day of my inspection, I witnessed the rig crew for Knox Energy and Bruce Levengood with Sound Energy packing off the well and putting a 4x2 swedge with a gate valve in the well. The well was drilled in 1973 but was never perforated or produced, Sound Energy is going to pressure test the casing and at that point decide if they will produce or plug the well.
1446498586 2015-11-02 Plug / Plug Back No Violations
1458825901 2016-03-24 Plug / Plug Back No Violations On the day of my inspection I witnessed the location was roughed in and I placed call to Sound Energy Field Representative Chuck Baker requesting when restoration would be completed. Mr. Baker stated that the final grade and seeding would take place in the coming weeks meeting the restoration date.
1676356591 2006-01-10 Production Wells No Violations WELL PRODUCING
1695825700 2015-11-03 Administrative Inspection No Violations NOV-1361899803 is resolved as well is now plugged.
1844221928 2015-12-23 Plug / Plug Back No Violations On the day of my inspection accompanied by ODNR Inspector Jim Nicholson checking on restoration, I witnessed the pit has been closed and the location has been graded with no seed or straw in place.
1890731852 2015-10-27 Plug / Plug Back No Violations On the day of my inspection following up NOV-1361899803, Berry Well Service and Appalachian Well Service was onsite. Appalachian Well Surveys tagged bottom at 5958 feet and perforated the Big Lime with 10 shots from 4270 feet to 4280 feet. BWS will trip in 1.5 inch tubing to commence plugging.
2078349957 2015-09-28 Production Wells No Violations On the day of my inspection following up NOV-1361899803, I witnessed there was no change in the status of the well since casing integrity test was performed on 6/30/15. A current plug permit was issued by the State on September 9, 2015.I spoke with Bruce Levengood of Sound Energy requesting an update and he stated that they are trying to line a rig to commence plugging operations.
560908775 2015-1-26 0:00: PW No Violations 1.00