X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-21192

Well Details

Well ID: 34-059-21192
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Monroe Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: MCCRACKEN ELLIS
License Status: Producing
License Date: 1970-01-16
Spud Date: 1970-05-01
Spud Drilling Contractor:
Final Drill Date: 1970-05-07
Well Total Depth: 5360.00 ft
Configuration: Vertical
Latitude: 40.200000
Longitude: -81.460000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1970-01-16 1333 BARR ROBT/dba BIG SKY PET GeoDate 1/16/70
Original Spud 1970-05-01 R.L. 4-23-70
Completed 1970-05-07 R.L. 4-23-70
Reached Total Depth 1970-05-07 R.L. 4-23-70
Construction Permit Expires 1971-01-16 R.L. 4-23-70
Record Last Modified 2013-10-03 R.L. 4-23-70

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5287 5327 0
5287 5327 0
5287 5327 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1653 Bbl 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 JAMES DRILLING CORP 894.00 0.00 0
1985 JAMES DRILLING CORP 1311.00 0.00 0
1986 JAMES DRILLING CORP 754.00 0.00 365
1987 JAMES DRILLING CORP 1423.00 0.00 365
1988 JAMES DRILLING CORP 1389.00 0.00 365
1989 JAMES DRILLING CORP 0.00 1096.00 365
1990 JAMES DRILLING CORP 727.00 0.00 365
1993 BIG SKY ENERGY INC 5320.00 0.00 365
1995 BIG SKY ENERGY INC 0.00 0.00 365
1996 BIG SKY ENERGY INC 0.00 0.00 0
1998 BIG SKY ENERGY INC 286.00 0.00 365
2000 BIG SKY ENERGY INC 0.00 0.00 365
2001 BIG SKY ENERGY INC 213.00 0.00 365
2003 BIG SKY ENERGY INC 612.00 0.00 365
2004 BIG SKY ENERGY INC 70.00 0.00 365
2005 BIG SKY ENERGY INC 1040.00 0.00 365
2006 BIG SKY ENERGY INC 958.00 0.00 365
2007 BIG SKY ENERGY INC 890.00 0.00 365
2008 BIG SKY ENERGY INC 237.00 0.00 365
2009 BIG SKY ENERGY INC 69.00 0.00 365
2011 BIG SKY ENERGY INC 2.00 0.00 365
2012 BIG SKY ENERGY INC 374.00 0.00 366
2013 BIG SKY ENERGY INC 211.00 0.00 250
2014 BIG SKY ENERGY INC 0.00 0.00 250
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 JAMES DRILLING CORP Brine 164 0
1985 JAMES DRILLING CORP Brine 0 0
1986 JAMES DRILLING CORP Brine 0 365
1987 JAMES DRILLING CORP Brine 25 365
1988 JAMES DRILLING CORP Brine 25 365
1989 JAMES DRILLING CORP Brine 0 365
1990 JAMES DRILLING CORP Brine 0 365
1993 BIG SKY ENERGY INC Brine 0 365
1995 BIG SKY ENERGY INC Brine 0 365
1996 BIG SKY ENERGY INC Brine 0 0
1998 BIG SKY ENERGY INC Brine 0 365
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 250
2014 BIG SKY ENERGY INC Brine 0 250
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1076744671 2019-12-17 0:00 PW No Violations 0.60
-1355178103 2020-6-5 0:00:0 PW No Violations 1.00
-1545288522 2019-3-13 0:00: PW No Violations 1.20
-1786204093 2015-4-28 0:00: PW No Violations 1.00
-1881297950 2006-6-12 0:00: PW No Violations
-2035902697 2012-4-4 0:00:0 PW No Violations
-448913109 2014-12-2 0:00: PW No Violations 1.50
0054948928 2008-05-01 Production Wells No Violations BARR POSTED ID ON WELLHEAD.
0132789462 2019-01-22 Production Wells No Violations

--105, and Compliance Notices -1357818813. No corrections have been made to gain compliance.

0232373594 2014-02-10 Production Wells No Violations On the day of my inspection following up NOV-1357818813, the ground was snow covered and I witnessed that compressor unit along the lease road was not running but the power was switched to auto. The lease road was gated and locked and the well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing, a plunger lift system and a logic controller. The valves were open on the flow line and opposite the flow line the valve was open to the atmosphere. The tank battery consisted of a 2-100bbl tanks which did not meet the minimum spacing requirements of 36 inches vertical separator. Identification was present but not legible.
0277686913 2007-08-02 Production Wells No Violations ID REWRITTEN.
0279441163 2016-04-17 Production Wells No Violations

---1357818813 and NOV-2035902697, I witnessed the lease road was gated, locked and impassible due to erosion. The well was equipped with 8.625 inch casing; 4.5 inch casing, 2.375 inch tubing and a plunger lift system with valves on the tubing in the closed position. A light gas smell was present at the wellhead and utilizing an ODNR Honeywell PhD6 meter revealed no gas detected. The production equipment included 2-100bbl tanks which did not meet the minimum spacing requirements of 36 inches within an earthen dike and a vertical separator. No identification was present with production records were current with zero production reported for 2014.

0322218128 2015-10-14 Production Wells No Violations On the day of my inspection following up NOV-1357818813 and NOV-2035902697, I witnessed that compressor unit along the lease road was running but the power was switched to auto. The lease road was gated, locked and impassible. The well was equipped with 8.625 inch casing; 4.5 inch casing, 2.375 inch tubing and a plunger lift system with valves on the tubing in the closed position. The production equipment included 2-100bbl tanks which did not meet the minimum spacing requirements of 36 inches and a vertical separator. Identification was present but not legible and no production has been reported for 2014.
0436765810 2012-04-04 Production Wells No Violations FOLLOW UP TO NOV # -2035902697 Inspection revealed that well is shut in and is equipped with conductor pipe and 8 surface casing and 4.5 production casing and 2 tubing and 2-100 bbl tanks which are located to close together and one of them is showing signs of seepage.

PLUG WELL WITHIN 60 DAYS OF FILE FOR TEMPORARY INACTIVE STATUS IF PLACED INTO PRODUCTION PROPERLY SPACE TANKS AND CONSTRUCT DIKE AROUND TANKS AND PROPERLY I.D. WELLHEAD. Failure to comply may result in bond forfeiture.

0448913109 2014-12-02 Production Wells No Violations On the day of my inspection following up NOV-1357818813 and NOV-2035902697 accompanied by Bob Barr President of Big Sky Energy, I witnessed that compressor unit along the lease road was not running but the power was switched to auto. The lease road was gated and locked and the well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing, a plunger lift system and a logic controller. The valves were open on the flow line and opposite the flow line the valve was open to the atmosphere. The tank battery consisted of a 2-100bbl tanks which did not meet the minimum spacing requirements of 36 inches and a vertical separator. Identification was present but not legible. Mr. Barr shut valve on casing for isolation purposes. Dan Goins presented Mr. Barr with current NOV-1357818813 and NOV-2035902697 for said well.
0549960971 2019-03-13 Production Wells No Violations The inspection is a Compliance Notice follow---inch tubing. The Demco tubing valve was closed, the two tubing valves were closed and the one casing valve is closed. There was a logic control box, murphy switch and motor valve that were not working. There was a small piece of pipe holding up the valve on the motor valve and no bull plug at the casing valve. The tank site consists of [2]100-barrel steel tanks placed within 8 inches of each other and 1 vertical separator with no pressure on the unit. The tanks are enclosed within an earthen impoundment and there was no identification posted. The briars have grown up around the production equipment and the well. The gas was till venting into the atmosphere. There was a sour gas smell but could not get readings with the Ventis pro 4 gas meter.
0664981207 2006-05-31 Production Wells No Violations PRODUCING WELL. ID REPOSTED. P/C IN DIKE AREA CLEANED UP.
0710188590 2016-03-17 Production Wells No Violations

-1357818813 and NOV-2035902697, I witnessed that compressor unit along the lease road was not running with the power switched to auto. The lease road was gated, locked and impassible due to erosion. The well was equipped with 8.625 inch casing; 4.5 inch casing, 2.375 inch tubing and a plunger lift system with valves on the tubing in the closed position. The production equipment included 2-100bbl tanks which did not meet the minimum spacing requirements of 36 inches within an earthen dike and a vertical separator. No identification was present and production records for 2014 have been submitted since the last inspection with zero production reported.

1137533818 2019-01-07 Production Wells Violations Noted The inspection was conducted in response to Complaint number 6047 and follow---inch tubing. The Demco tubing valve was closed, the two tubing valves were closed and the one casing valve is closed. There was a logic control box, murphy switch and motor valve that were not working. There was a small piece of pipe holding up the valve on the motor valve and no bull plug at the casing valve. The tank site consists of [2]100-barrel steel tanks placed within 8 inches of each other and 1 vertical separator with no pressure on the unit. The tanks are enclosed within an earthen impoundment and there was no identification posted. The briars have grown up around the production equipment and the well. The company has 5 days to install the bull plugs needed and 5 days to prevent the well from emitting H2S from the well.
1289424772 2019-01-22 Production Wells No Violations The day of this inspection Austin Gutridge accompanied me on a compliance notice follow-up to number 1137533818 and complaint number 6047. We stopped at the entrance of the well. The snow and ice made the road impassable to get to the well.
132789462 2019-1-22 0:00: PW No Violations 3.00
1334453895 2017-01-26 Production Wells No Violations

---1357818813 and NOV-2035902697, I witnessed the lease road was gated, locked and impassible due to erosion. The well was equipped with 8.625 inch diameter casing; 4.5 inch diameter casing, 2.375 inch diameter tubing and a plunger lift system with valves on the tubing in the closed position. A strong gas smell was present at the wellhead and utilizing an ODNR Honeywell PhD6 meter revealed LEL levels at 6. The production equipment included 2-100 barrel tanks which do not meet the minimum spacing requirements of 36 inches within an earthen dike and a vertical separator. No identification was present and the production records were not current.

1357682473 2013-01-08 Administrative Inspection No Violations As per Mike Hartshorns inspection revealing that well is capable of producing resolving previous compliance notice issued for idle well owner has complied with issue and has placed dike around tanks but has failed to correct spacing requirement and has not properly identified well and has not complied with request to report production as required by law, local inspector Mike Hartshorn will reissue notice for tank spacing requirement and to post proper identification.

Note: Received notice from landowners attorney stating that lease has been cancelled and current owner has no right to attempt to produce well.

1357818813 2013-01-10 Production Wells Violations Noted On the ninth day of January 2013, I made an attempt to contact Big Sky Petroleum LLC and left a message with Bob Barr to let him know that enforcement may be required due to lease cancellation on pursuant to affidavit of forfeiture see O.R. 491 Pg. 1339 see O.R. 493 Pg 1232. I left a message on Bob Barrs voice mail to return my call. On the tenth of January 2013 I received a phone call from Bob Barr, he informed me that he complied with the state and the well was back in production. After speaking with Mr. Barr I drove to the well site to do an inspection, the inspection revealed at the well head the two inch gate valve was open as well as the valve on the production line. There is no identification posted, there has been no production records recorded since the year of 2009. There is a compressor at the beginning of the entry way leading back to the well site. The violations at the well site are, / 1501: 9-9-05(A)10 failure to legible identify well/ 9-9-05(A)2 violation of tank spacing/ 1509.11. Statement of production. The requirements to meet the divisions standards will be, 1. Properly identify the well 2. Meet the minimum requirements of three foot spacing between the tanks. 3. Meet the divisions standards for the statement of production.
1469477231 2006-10-11 Production Wells No Violations PRODUCING WELL
1545288522 2019-03-13 Production Wells No Violations

--105, and Compliance Notice -1357818813. During our inspection today, we traveled the heavily eroded lease road on foot back to the well. The well was equipped with 8.625-inch diameter surface casing with a casing head, 4.5-inch diameter production casing with a tubing head, 2.375-inch diameter tubing, and a plunger lift system. All valves were in the closed position. The Demco master valve was in the closed position on the tubing and no lines were attached to the production casing. A sour gas smell can be identified by the wellhead. While utilizing the Ventis pro 4 gas detector no Hydrogen Sulfide Gas recordings were detected. The production equipment consisted of two 100-barrel tanks and one vertical separator. The two 100-barrel tanks were within 3-feet apart and did not meet spacing requirements stated in the Ohio Administrative Code 1501:9-9-05(A)(2). Identification was not posted within a conspicuous place near the wellhead or production equipment.

1566316960 2019-8-20 0:00: PW No Violations 0.50
1586528375 2020-4-10 0:00: PW No Violations 1.00
1786204093 2015-04-28 Production Wells No Violations On the day of my inspection following up NOV-1357818813 and NOV-2035902697, I witnessed that compressor unit along the lease road was running but the power was switched to auto. The lease road was gated and locked and the well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing and a plunger lift system with valves on the tubing in the closed position. The production equipment included 2-100bbl tanks which did not meet the minimum spacing requirements of 36 inches and a vertical separator. Identification was present but not legible and no production has been reported for 2013 and 2014.
1881297950 2006-06-12 Production Wells No Violations PRODUCING WELL.
2035902697 2012-04-04 Production Wells Violations Noted Inspection revealed that well is shut in and is equipped with conductor pipe and 8 surface casing and 4.5 production casing and 2 tubing and 2-100 bbl tanks which are located to close together and one of them is showing signs of seepage.

PLUG WELL WITHIN 60 DAYS OF FILE FOR TEMPORARY INACTIVE STATUS IF PLACED INTO PRODUCTION PROPERLY SPACE TANKS AND CONSTRUCT DIKE AROUND TANKS AND PROPERLY I.D. WELLHEAD. Failure to comply may result in bond forfeiture.

2040471187 2018-02-06 Production Wells No Violations

---1357818813 and NOV-2035902697, I witnessed the lease road was gated, locked and impassible due to erosion. The well was equipped with 8.625 inch diameter casing; 4.5 inch diameter casing, 2.375 inch diameter tubing and a plunger lift system with valves on the tubing in the closed position. A strong gas smell was present at the wellhead and utilizing an ODNR Honeywell PhD6 meter revealed LEL levels at 8 with visible bubbling around the packing on the 4.5 inch diameter casing. The production equipment included 2-100 barrel tanks which do not meet the minimum spacing requirements of 36 inches within an earthen dike and a vertical separator. No identification was present and the production records were current.

232373594 2014-2-10 0:00: PW No Violations 1.00
277686913 2007-8-2 0:00:0 PW No Violations
279441163 2016-4-17 0:00: PW No Violations 1.00
322218128 2015-10-14 0:00 PW No Violations 1.00
436765810 2012-4-4 0:00:0 PW No Violations
54948928 2008-5-1 0:00:0 PW No Violations
549960971 2019-3-13 0:00: PW No Violations 1.30
664981207 2006-5-31 0:00: PW No Violations
703979643 2020-11-3 0:00: PW No Violations 1.00
710188590 2016-3-17 0:00: PW No Violations 1.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1137533818 US-OH-103469 2019-01-11 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas
1137533818 US-OH-103470 2019-01-11 9-9-05(D) Failure to have required locks, bull plugs
1357818813 US-OH-110353 2013-02-27 Failure to legibly identify well
1357818813 US-OH-110354 2013-02-27 Violation of tank spacing requirements
2035902697 US-OH-120708 2013-01-11 Well operation causing pollution and contamination
2035902697 US-OH-120709 2013-01-11 General Safety
2035902697 US-OH-120710 2013-01-11 Failure to legibly identify well
2035902697 US-OH-120711 2013-01-11 No SPCC dike/or failure to keep dike free of water or oil
2035902697 US-OH-120712 2013-01-11 Well shall be plugged
2035902697 US-OH-120713 2013-01-11 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[9]