X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-20996

Well Details

Well ID: 34-059-20996
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Monroe Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: KEISER E
License Status: Producing
License Date: 1969-07-11
Spud Date: 1969-06-30
Spud Drilling Contractor:
Final Drill Date: 1969-10-03
Well Total Depth: 5337.00 ft
Configuration: Vertical
Latitude: 40.190000
Longitude: -81.490000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1969-06-30
CO 1969-07-11 1333 BARR ROBT/dba BIG SKY PET GeoDate 7/11/69
Completed 1969-10-03
Reached Total Depth 1969-10-03
Construction Permit Expires 1970-07-11
Record Last Modified 2013-10-03

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1632 Bbl 56000 FROM NSR

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 JAMES DRILLING CORP 6917.00 0.00 0
1985 JAMES DRILLING CORP 3147.00 0.00 0
1986 JAMES DRILLING CORP 1903.00 0.00 365
1987 JAMES DRILLING CORP 3587.00 0.00 365
1988 JAMES DRILLING CORP 3508.00 0.00 365
1989 JAMES DRILLING CORP 0.00 2743.00 365
1990 JAMES DRILLING CORP 1700.00 0.00 365
1993 BIG SKY ENERGY INC 4876.00 0.00 365
1995 BIG SKY ENERGY INC 9471.00 0.00 365
1996 BIG SKY ENERGY INC 10495.00 34.00 365
1998 BIG SKY ENERGY INC 665.00 0.00 365
2000 BIG SKY ENERGY INC 0.00 0.00 365
2001 BIG SKY ENERGY INC 213.00 0.00 365
2003 BIG SKY ENERGY INC 491.00 0.00 365
2004 BIG SKY ENERGY INC 57.00 0.00 365
2005 BIG SKY ENERGY INC 821.00 0.00 365
2006 BIG SKY ENERGY INC 758.00 0.00 365
2007 BIG SKY ENERGY INC 703.00 0.00 365
2008 BIG SKY ENERGY INC 187.00 0.00 365
2009 BIG SKY ENERGY INC 54.00 0.00 365
2011 BIG SKY ENERGY INC 3.00 0.00 365
2012 BIG SKY ENERGY INC 473.00 0.00 366
2013 BIG SKY ENERGY INC 365.00 46.00 365
2014 BIG SKY ENERGY INC 555.00 0.00 365
2016 BIG SKY ENERGY INC 117.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 JAMES DRILLING CORP Brine 48 0
1985 JAMES DRILLING CORP Brine 0 0
1986 JAMES DRILLING CORP Brine 0 365
1987 JAMES DRILLING CORP Brine 0 365
1988 JAMES DRILLING CORP Brine 0 365
1989 JAMES DRILLING CORP Brine 0 365
1990 JAMES DRILLING CORP Brine 0 365
1993 BIG SKY ENERGY INC Brine 0 365
1995 BIG SKY ENERGY INC Brine 0 365
1996 BIG SKY ENERGY INC Brine 0 365
1998 BIG SKY ENERGY INC Brine 0 365
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1072116881 2015-7-8 0:00:0 PW No Violations 1.50
-1190987126 2020-4-7 0:00:0 PW No Violations 1.00
-1760146113 2014-12-3 0:00: PW No Violations 1.50
-1907094727 2016-4-17 0:00: PW No Violations 1.00
-2073386149 2018-2-6 0:00:0 PW No Violations 1.00
-379013396 2004-7-23 0:00: PW No Violations
-659268590 2015-10-14 0:00 PW No Violations 1.00
-983739948 2019-3-13 0:00: PW No Violations 0.50
0016122590 2013-10-10 Production Wells No Violations On the day of My inspection, I found the gate valve on the tubing in the open position, I reviewed the production records for The Division of Oil and Gas and found the gas sales for the year of 2012 meet the Division of Oil and Gas Standards. The Director of Pikes Peak Camp Ground was at the well site when I done my inspection and stated to me that they were under instruction from there attorney not to let any person with Big Sky Energy in the camp ground to service the well or make any change to the well.
0302754644 2012-04-04 Production Wells No Violations FOLLOW UP TO NOV # 381290286 Inspection revealed that well is idle and is equipped with 8 surface casing and 4.5 production casing and 2 tubing and 1-100 bbl tank with no dike around it and no identification could be found on wellhead or tank and last production reported was back in 2009.

PLUG WELL WITHIN 60 DAYS OR FILE FOR TEMPORARY INACTIVE STATUS. Failure to comply may result in bond forfeiture.

0379013396 2004-07-23 Production Wells No Violations STATUS CHECK. NO PRODUCTION REPORTS SINCE 2001.
0381290286 2012-04-04 Production Wells Violations Noted Inspection revealed that well is idle and is equipped with 8 surface casing and 4.5 production casing and 2 tubing and 1-100 bbl tank with no dike around it and no identification could be found on wellhead or tank and last production reported was back in 2009.

PLUG WELL WITHIN 60 DAYS OR FILE FOR TEMPORARY INACTIVE STATUS. Failure to comply may result in bond forfeiture.

0659268590 2015-10-14 Production Wells No Violations On the day of my inspection following up on NOV-381290286, I witnessed that there was no change in the status of the well and the production equipment included a vertical separator and a 100bbl tank with no dike. The well was equipped with 4.5 inch casing, 2.375 inch tubing, a plunger lift system and a 2 inch flow line. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Identification was present with no production records filed for 2014.
0740521140 2016-03-17 Production Wells No Violations On the day of my inspection following up on Compliance Notice-381290286, I witnessed that there was no change in the status of the well and the production equipment included a vertical separator and a 100bbl tank with no dike. The well was equipped with 4.5 inch casing, 2.375 inch tubing and a plunger lift system. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Debris was piled near and around the wellhead creating an unsafe right away to the well. Identification was present and production records for 2014 have been submitted since the last inspection.
0880743218 2017-01-26 Production Wells No Violations

--105 and Compliance Notice-381290286, I witnessed that there was no change in the status of the well and the production equipment included a vertical separator and a 100 barrel tank with no dike. The well was equipped with 4.5 inch diameter casing; 2.375 inch diameter tubing and a plunger lift system. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Identification was present and the production records were not current.

0983739948 2019-03-13 Production Wells No Violations

--105, and Compliance Notice-381290286. The well was equipped with 4.5-inch casing with a tubing head, 2.375-inch tubing, and a plunger lift system. The production valves were in the closed position with the tubing valve chained and locked in the closed position. The production equipment included one vertical separator and one 100-barrel tank. Big Sky Energy has submitted reports of zero production for the year 2017.

1072116881 2015-07-08 Production Wells No Violations On the day of my inspection accompanied by Southeast Regional Supervisor Brent Bear following up on NOV-381290286, I witnessed that the production equipment included a vertical separator and a 100bbl tank with no dike. The well was equipped with 4.5 inch casing, 2.375 inch tubing, a plunger lift system and a 2 inch flow line. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Identification was present with no production records filed for 2014. We met with Pikes Peak RV Camp Director Craig Kerner and he stated the well has not been produced for 2 years.
1176937941 2012-04-04 Production Wells No Violations FOLLOW UP TO NOV # 381290286 Inspection revealed that well is idle and is equipped with 8 surface casing and 4.5 production casing and 2 tubing and 1-100 bbl tank with no dike around it and no identification could be found on wellhead or tank and last production reported was back in 2009.

PLUG WELL WITHIN 60 DAYS OR FILE FOR TEMPORARY INACTIVE STATUS. Failure to comply may result in bond forfeiture.

1206734603 2015-04-28 Production Wells No Violations On the day of my inspection following up on NOV-381290286, I witnessed that the tank battery was equipped with a vertical separator, a 100bbl tank with no dike. The well was equipped with 4.5 inch casing, 2.375 inch tubing, a plunger lift system and a 2 inch flow line. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Identification was present. Identification was present with no production records filed for the years 2013 and 2014.
1354655966 2012-12-04 Production Wells No Violations Pryor to my inspection I received a phone call from Mr. John Hinterschied requesting me to do an inspection on well I.D.# 34-059-2-0996-0000, after doing my inspection I seen the valve on the two inch tubing coming out of the well was closed, there is (1) one hundred barrel production tank/ separator setting at the road side with no containment dike around them, the divisions production records shows no recorded production since the year of 2009. There was an inspection done and a compliance sent out on 04 of 2012.
1392223374 2014-02-12 Production Wells No Violations On the day of my inspection following up on NOV-381290286, I witnessed that the tank battery was equipped with a vertical separator, a 100bbl tank with no dike. The well was equipped with 4.5 inch casing, 2.375 inch tubing, a plunger lift system and a 2 inch flow line. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Identification was present.
1459798689 2016-04-04 Production Wells No Violations

-105 and Compliance Notice-381290286, I witnessed that there was no change in the status of the well and the production equipment included a vertical separator and a 100bbl tank with no dike. The well was equipped with 4.5 inch casing, 2.375 inch tubing and a plunger lift system. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. The debris which was piled near and around the wellhead has been removed allowing access to the well. Identification was present and production records for 2014 have been submitted since the last inspection.

1541431328 2018-11-05 Production Wells No Violations

--105, and Compliance Notice-381290286. The well was equipped with 4.5-inch casing with a tubing head, 2.375-inch tubing, and a plunger lift system. The production valves were in the closed position with the tubing valve chained and locked in the closed position. The production equipment included one vertical separator and one 100-barrel tank with steel flowlines lying on the surface. A faded identification sticker was located on the tank. Big Sky Energy has submitted reports of zero production for the year 2017.

16122590 2013-10-10 0:00 PW No Violations
1691433270 2020-11-2 0:00: PW No Violations 1.00
1760146113 2014-12-03 Production Wells No Violations On the day of my inspection following up on NOV-381290286, I witnessed that the production equipment included a vertical separator and a 100bbl tank with no dike. The well was equipped with 4.5 inch casing, 2.375 inch tubing, a plunger lift system and a 2 inch flow line. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Identification was present.
1907094727 2016-04-17 Production Wells No Violations

--105 and Compliance Notice-381290286, I witnessed that there was no change in the status of the well and the production equipment included a vertical separator and a 100bbl tank with no dike. The well was equipped with 4.5 inch casing; 2.375 inch tubing and a plunger lift system. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Identification was present and production records were current showing production for 2014.

1920548003 2020-6-5 0:00:0 PW No Violations 1.00
1929243767 2006-06-12 Production Wells No Violations PRODUCING WELL
2073386149 2018-02-06 Production Wells No Violations

--105 and Compliance Notice-381290286, I witnessed that there was no change in the status of the well and the production equipment included a vertical separator and a 100 barrel tank with no dike. The well was equipped with 4.5 inch diameter casing; 2.375 inch diameter tubing and a plunger lift system. The tubing gate valve was closed, chained, locked and all other valves were closed at the well head. Identification was present but faded and the production records were reported for 2016 showing gas production.

302754644 2012-4-4 0:00:0 PW No Violations
381290286 2012-4-4 0:00:0 PW No Violations
740042309 2019-11-5 0:00: PW No Violations 0.50
740521140 2016-3-17 0:00: PW No Violations 1.50
880743218 2017-1-26 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0381290286 US-OH-124035 2012-04-15 General Safety
0381290286 US-OH-124036 2012-04-15 No SPCC dike/or failure to keep dike free of water or oil
0381290286 US-OH-124037 2012-04-15 Well shall be plugged
0381290286 US-OH-124038 2012-04-15 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[8]

References