X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-20995

Well Details

Well ID: 34-059-20995
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Monroe Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: E KEISER-H HUNNEL
License Status: Producing
License Date: 1969-07-11
Spud Date: 1969-07-31
Spud Drilling Contractor:
Final Drill Date: 1969-10-30
Well Total Depth: 5342.00 ft
Configuration: Vertical
Latitude: 40.190000
Longitude: -81.480000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1969-07-11 1333 BARR ROBT/dba BIG SKY PET GeoDate 7/11/69
Original Spud 1969-07-31
Completed 1969-10-30
Reached Total Depth 1969-10-30
Construction Permit Expires 1970-07-11
Record Last Modified 2013-10-03

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1600 Bbl 60000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 JAMES DRILLING CORP 7450.00 0.00 0
1985 TITAN ENERGY CORP 1606.00 76.00 365
1986 JAMES DRILLING CORP 2053.00 0.00 365
1987 JAMES DRILLING CORP 3866.00 0.00 365
1988 JAMES DRILLING CORP 3775.00 0.00 365
1989 JAMES DRILLING CORP 0.00 2954.00 365
1990 JAMES DRILLING CORP 1828.00 0.00 365
1993 BIG SKY ENERGY INC 4876.00 0.00 365
1995 BIG SKY ENERGY INC 0.00 0.00 365
1996 BIG SKY ENERGY INC 0.00 53.00 0
1998 BIG SKY ENERGY INC 665.00 0.00 365
2000 BIG SKY ENERGY INC 0.00 0.00 365
2001 BIG SKY ENERGY INC 213.00 0.00 365
2003 BIG SKY ENERGY INC 491.00 0.00 365
2004 BIG SKY ENERGY INC 57.00 0.00 365
2005 BIG SKY ENERGY INC 822.00 0.00 365
2006 BIG SKY ENERGY INC 758.00 0.00 365
2007 BIG SKY ENERGY INC 702.00 0.00 365
2008 BIG SKY ENERGY INC 187.00 0.00 365
2009 BIG SKY ENERGY INC 54.00 0.00 365
2011 BIG SKY ENERGY INC 2.00 0.00 365
2012 BIG SKY ENERGY INC 374.00 0.00 366
2013 BIG SKY ENERGY INC 365.00 0.00 365
2014 BIG SKY ENERGY INC 0.00 0.00 365
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 JAMES DRILLING CORP Brine 48 0
1985 TITAN ENERGY CORP Brine 0 365
1986 JAMES DRILLING CORP Brine 0 365
1987 JAMES DRILLING CORP Brine 0 365
1988 JAMES DRILLING CORP Brine 0 365
1989 JAMES DRILLING CORP Brine 0 365
1990 JAMES DRILLING CORP Brine 0 365
1993 BIG SKY ENERGY INC Brine 0 365
1995 BIG SKY ENERGY INC Brine 0 365
1996 BIG SKY ENERGY INC Brine 0 0
1998 BIG SKY ENERGY INC Brine 0 365
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1043078415 2017-1-26 0:00: PW No Violations 1.00
-1264413718 2012-6-21 0:00: PW No Violations
-132436218 2016-4-17 0:00: PW No Violations 1.00
-1518680336 2015-4-28 0:00: PW No Violations 1.00
-1674813266 2016-4-20 0:00: PW No Violations 1.00
-1799465226 2014-12-3 0:00: PW No Violations 1.50
-1986821897 2014-2-12 0:00: PW No Violations 2.50
-253080108 2019-11-5 0:00: PW No Violations 0.50
-616936909 2018-11-5 0:00: PW No Violations 1.00
0132436218 2016-04-17 Production Wells No Violations

--105 and Compliance Notice-1334527233, I witnessed the well was fenced and locked with access being gained from the Rocky Fork camp grounds staff. The production equipment included a 100bbl tank with no plug present in the drain valve and a small amount of contamination at the valve within an earthen dike and a vertical separator. The well was equipped with 8.625 inch casing; 4.5 inch casing and a casing lift system with valves in the open position. Identification was present with production records were current with zero production reported for 2014.

0138560999 2012-04-04 Production Wells No Violations FOLLOW UP TO NOV # 1334527233 Inspection revealed that well is idle and is equipped with 8 surface casing and 4.5 production casing and 2 tubing and 1-100 bbl tank with no dike around it and no identification could be found on wellhead or tank and last production reported was back in 2009.

PLUG WELL WITHIN 60 DAYS OR FILE FOR TEMPORARY INACTIVE STATUS. Failure to comply may result in bond forfeiture.

0188065689 2018-11-05 Production Wells No Violations

--105, and Compliance Notice-1334527233. During my inspection a wooden fence with a locked gate surrounded the well preventing access from the campground. I gained access to the well from the Rocky Fork Campground staff. The well was fenced and locked with access being gained from the Rocky Fork camp grounds staff. The well was equipped with 8.625-inch diameter casing with casing head and 4.5-inch diameter production casing with a ConCoyle lift system. Production valves were in the closed position. The production equipment consisted of one vertical separator and one 100-barrel tank. Big Sky Energy has submitted reports of zero production for the year 2016 and 2017.

0616936909 2018-11-05 Production Wells No Violations

--105, and Compliance Notice-1334527233. During my inspection a wooden fence with a locked gate surrounded the well preventing access from the campground. I gained access to the well from the Rocky Fork Campground staff. The well was fenced and locked with access being gained from the Rocky Fork camp grounds staff. The well was equipped with 8.625-inch diameter casing with casing head and 4.5-inch diameter production casing with a ConCoyle lift system. Production valves were in the closed position. The production equipment consisted of one vertical separator and one 100-barrel tank. Big Sky Energy has submitted reports of zero production for the year 2016 and 2017.

0808098522 2003-04-07 Production Wells No Violations STATUS CHECK
0954701220 2012-04-04 Production Wells No Violations FOLLOW UP TO NOV # 1334527233 Inspection revealed that well is idle and is equipped with 8 surface casing and 4.5 production casing and 2 tubing and 1-100 bbl tank with no dike around it and no identification could be found on wellhead or tank and last production reported was back in 2009.

PLUG WELL WITHIN 60 DAYS OR FILE FOR TEMPORARY INACTIVE STATUS. Failure to comply may result in bond forfeiture.

0985673597 2004-07-23 Production Wells No Violations STATUS CHECK. NO PRODUCTION REPORTS SINCE 2001.
1043078415 2017-01-26 Production Wells No Violations

--105 and Compliance Notice-1334527233, I witnessed the well was fenced and locked with access being gained from the Rocky Fork camp grounds staff. The production equipment included a 100 barrel tank with no plug present in the drain valve and a small amount of contamination at the valve within an earthen dike and a vertical separator. The well was equipped with 8.625 inch diameter casing; 4.5 inch diameter casing and a casing lift system with valves in the closed position. Identification was present and the production records were not current.

1175796645 2016-03-17 Production Wells No Violations On the day of my inspection following up on Compliance Notice -1334527233, I witnessed that the production equipment included a 100bbl tank with no plug present in the drain valve and a small amount of contamination at the valve within an earthen dike and a vertical separator. The well was equipped with 8.625 inch casing, 4.5 inch casing and a casing lift system with valves in the open position. Identification was present with production records being filed since the last inspection for the years 2013 and 2014 with zero production reported for 2014.
1264413718 2012-06-21 Production Wells No Violations On the day of my inspection I received a call from Mark Shambaugh at Glenn Heaven resort, the well was venting gas out of production tank, at the time of my inspection the well was not venting gas, I then called Big Sky Energy, they told me the pumper had been there and replaced the valve.
1334527233 2012-04-04 Production Wells Violations Noted Inspection revealed that well is idle and is equipped with 8 surface casing and 4.5 production casing and 2 tubing and 1-100 bbl tank with no dike around it and no identification could be found on wellhead or tank and last production reported was back in 2009.

PLUG WELL WITHIN 60 DAYS OR FILE FOR TEMPORARY INACTIVE STATUS. Failure to comply may result in bond forfeiture.

1340298797 2012-10-12 Production Wells No Violations On the day of my inspection I meet with the land owner, he told me that the well had been venting gas throught the nite, when I went to the well site it was not venting at that time, I then called Big Sky Energy to make them aware of the problem, after speaking with them they informed me that the pumper had been there that morning to make the repairs.
1373690452 2020-11-3 0:00: PW No Violations 1.00
138560999 2012-4-4 0:00:0 PW No Violations
1518680336 2015-04-28 Production Wells No Violations On the day of my inspection following up on NOV-1334527233, I witnessed that the tank battery was equipped with a vertical separator, a 100bbl tank with no plug present in the drain valve and a small amount of contamination at the valve within an earthen dike. The well was equipped with 8.625 inch casing, 4.5 inch casing with a concoil catcher and was open flowing into a 1.25 inch hose connecting to a 2 inch flow line all other valves were open at the well head. Identification was present with no production records filed for the years 2013 and 2014.
1674813266 2016-04-20 Production Wells No Violations

--105 and Compliance Notice-1334527233, I witnessed the production equipment included a 100bbl tank with no plug present in the drain valve and a small amount of contamination at the valve within an earthen dike and a vertical separator. The well was equipped with 8.625 inch casing; 4.5 inch casing and a casing lift system with valves in the closed position. Identification was present with production records were current with zero production reported for 2014. Following up at the Ash Road compressor station no gas was flowing through the meter.

1674935020 2006-06-12 Production Wells No Violations PRODUCING WELL
1698855168 2018-02-06 Production Wells No Violations

--105 and Compliance Notice-1334527233, I witnessed the well was fenced and locked with access being gained from the Rocky Fork camp grounds staff. The production equipment included a 100 barrel tank with no plug present in the drain valve. The well was equipped with 8.625 inch diameter casing; 4.5 inch diameter casing and a casing lift system with valves in the closed position. Identification was present but faded and the production records were current.

1799465226 2014-12-03 Production Wells No Violations On the day of my inspection following up on NOV-1334527233, I witnessed that the production equipment included a vertical separator and a 100bbl tank with no dike. The well was equipped with 4.5 inch casing was open flowing into a 1.25 inch hose connecting to a 2 inch flow line all other valves were open at the well head. Identification was present and production records are current. Contamination was still present around tank.
188065689 2018-11-5 0:00: PW No Violations 1.00
1986821897 2014-02-12 Production Wells No Violations On the day of my inspection following up on NOV-1334527233, I witnessed that the tank battery was equipped with a vertical separator, a 100bbl tank with no dike. The well was equipped with 4.5 inch casing was open flowing into a 1.25 inch hose connecting to a 2 inch flow line all other valves were open at the well head. Identification was present but not legible.
2003965951 2019-03-13 Production Wells No Violations

--105, and Compliance Notice-1334527233. During my inspection the well was equipped with 8.625-inch diameter casing with casing head and 4.5-inch diameter production casing with a ConCoyle lift system. Production valves were in the closed position. The production equipment consisted of one vertical separator and one 100-barrel tank. Big Sky Energy has submitted reports of zero production for the year 2016 and 2017.

2106687212 2020-4-10 0:00: PW No Violations 1.00
808098522 2003-4-7 0:00:0 PW No Violations
954701220 2012-4-4 0:00:0 PW No Violations
985673597 2004-7-23 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1334527233 US-OH-109612 2012-04-15 General Safety
1334527233 US-OH-109613 2012-04-15 Failure to legibly identify well
1334527233 US-OH-109614 2012-04-15 No SPCC dike/or failure to keep dike free of water or oil
1334527233 US-OH-109615 2012-04-15 Well shall be plugged
1334527233 US-OH-109616 2012-04-15 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[8]

References