Well Details

Well ID: 34-059-20925
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Buffalo Township
Operator Name: AVA GAS CORP
Well Pad ID:
Farm/Lease Name: KEATON BETTY JO
License Status: Producing
License Date: 1969-03-13
Spud Date: 1969-03-25
Spud Drilling Contractor:
Final Drill Date: 1969-06-04
Well Total Depth: 5335.00 ft
Configuration: Vertical
Latitude: 39.840000
Longitude: -81.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1969-03-25 TRANSFERRED TO AVA GAS CORP. ON 10-7-87 817.3=GL, 41.47=ACRES I.P. 1,542 CFG.
Completed 1969-06-04 TRANSFERRED TO AVA GAS CORP. ON 10-7-87 817.3=GL, 41.47=ACRES I.P. 1,542 CFG.
Reached Total Depth 1969-06-04 TRANSFERRED TO AVA GAS CORP. ON 10-7-87 817.3=GL, 41.47=ACRES I.P. 1,542 CFG.
CO 1987-10-07 2815 AVA GAS CORP
Record Last Modified 2013-10-03 TRANSFERRED TO AVA GAS CORP. ON 10-7-87 817.3=GL, 41.47=ACRES I.P. 1,542 CFG.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5179 5251 22
5179 5251 22
5179 5251 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 5190 Bbl 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 SCION ENERGY INC 445.00 0.00 0
1985 SCION ENERGY INC 0.00 0.00 365
1986 SCION ENERGY INC 28.00 0.00 365
1992 AVA GAS CORP 0.00 0.00 0
1993 AVA GAS CORP 0.00 0.00 365
1994 AVA GAS CORP 0.00 0.00 365
1995 AVA GAS CORP 0.00 0.00 365
1996 AVA GAS CORP 0.00 0.00 365
1997 AVA GAS CORP 0.00 0.00 365
2005 AVA GAS CORP 0.00 0.00 0
2009 AVA GAS CORP 0.00 0.00 365
2010 AVA GAS CORP 0.00 0.00 365
2011 AVA GAS CORP 0.00 0.00 0
2012 AVA GAS CORP 0.00 0.00 0
2013 AVA GAS CORP 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 SCION ENERGY INC Brine 0 0
1985 SCION ENERGY INC Brine 0 365
1986 SCION ENERGY INC Brine 0 365
1992 AVA GAS CORP Brine 0 0
1993 AVA GAS CORP Brine 0 365
1994 AVA GAS CORP Brine 0 365
1995 AVA GAS CORP Brine 0 365
1996 AVA GAS CORP Brine 0 365
1997 RESOURCE AMERICA INC Brine 0 365
2005 AVA GAS CORP Brine 0 0
2009 AVA GAS CORP Brine 0 365
2010 AVA GAS CORP Brine 0 365
2011 AVA GAS CORP Brine 0 0
2012 AVA GAS CORP Brine 0 0
2013 AVA GAS CORP Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1019896252 2009-12-1 0:00: PW No Violations
-1225121000 2014-9-16 0:00: PW No Violations 1.00
-1684871625 2020-11-4 0:00: PW No Violations 1.00
-1748590723 2020-9-21 0:00: PW No Violations 1.00
-2052995591 2015-6-16 0:00: PW No Violations 0.50
-2055870203 2016-3-29 0:00: PW No Violations 1.00
-2085783978 2008-2-28 0:00: PW No Violations
-446318992 2009-11-19 0:00 PW No Violations
-475857591 2015-2-2 0:00:0 PW No Violations 1.00
-542307330 2008-3-26 0:00: PW No Violations
-736330393 2008-5-27 0:00: PW No Violations
-905419545 2019-8-14 0:00: PW No Violations 0.50
0130536254 2009-12-01 Production Wells No Violations FOLLOW UP TO NOV # 1259675749 Upon inspecting site at request from supervisor found well producing for domestic purposes only,owner is currently operating without proper bonding,and there is no I.D. at well.
0192041510 2008-10-03 Production Wells No Violations WELL IS BEING USED FOR DOMESTIC GAS. NOV RESOLVED.
0289383195 2012-11-07 Production Wells No Violations My inspection today finds that the well appears to be used only for domestic gas.
0302824357 2017-02-01 Production Wells No Violations On the day of my inspection following up on NOV-1259675749, I witnessed there was no change in the status of the well since the last inspection on March 29, 2016. The well was equipped with 8.625 inch diameter casing and 4.5 inch diameter casing reduced to 2 inches and domestic gas service with the one valve open supplying domestic gas service. Gauge present on the casing read 225 pounds per square inch with identification present. Production equipment included a disconnected horizontal separator.
0446318992 2009-11-19 Production Wells No Violations Inspection revealed that well is equipped with 8 surface casing and 4.5 production casing and 1-seperator not hooked up, there is 1 domestic hookup noted at wellhead and it appears that there was 2 hookups at well at some point noted that one line has been disconnected from wellhead,and 3 photos were taken during my inspection.
0475857591 2015-02-02 Production Wells No Violations On the day of my inspection following up on NOV--41, I witnessed the well was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with the valve open providing domestic gas service. Production equipment included a disconnected horizontal separator and no salesline with identification present at the time of inspection.
0494968738 2015-07-13 Production Wells No Violations On the day of my inspection following up on NOV-1259675749, I witnessed there was no change in the status of the well and it was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with the valve open providing domestic gas service. Gauge present on the casing read 228psi with identification present at the time of inspection. Production equipment included a disconnected horizontal separator. I met with current landowner Charles Armstrong who stated that he has been the landowner since 1990 and has been receiving gas since purchasing the property. Mr. Armstrong also stated that he would be interesting in acquiring the well.
0542307330 2008-03-26 Production Wells Violations Noted WELL IS BEING USED FOR DOMESTIC GAS. INSPECTION THIS DATE RESOLVED THIS VIOLATION
0736330393 2008-05-27 Production Wells No Violations RESOLVED . BEING USED FOR HOUSE GAS.
1019896252 2009-12-01 Production Wells No Violations FOLLOW UP TO NOV # 1259675749 Upon inspecting site at request from supervisor found well producing for domestic purposes only,owner is currently operating without proper bonding,and there is no I.D. at well.
1064568810 2018-02-01 Production Wells No Violations On the day of my inspection following up on NOV-1259675749, I witnessed there was no change in the status of the well since the last inspection on February 1, 2017. The well was equipped with 8.625 inch diameter casing and 4.5 inch diameter casing reduced to 2 inches and domestic gas service with the one valve open supplying domestic gas service. Gauge present on the casing read 225 pounds per square inch with identification present. Production equipment included a disconnected horizontal separator.
1156258062 2006-08-22 Administrative Inspection No Violations INSPECTED WELL AS PER JOE HOERST REQUEST. FOUND WELL TO BE USE DFOR DOMESTIC GAS TO LONNIE WATSON AND CHARLES ARMSTRONG RESIDENCE. CONVERSATION WITH MR. ARMSTRONG TO ASCERTAIN HE REALLY WAS USING GAS OFF THIS WELL.MR. WATSON WAS INSTRUCTED TO GET ID ON THE WELLHEAD IMMEDIATELY. WE WENT TO HIS SHOP,MADE UP AN ID AND POSTED ID AT WELLHEAD.
115834645 2019-8-14 0:00: PW No Violations 0.50
1225121000 2014-09-16 Production Wells No Violations My inspection finds the well is being used to for domestic gas only. The owner has still not obtained insurance or posted bond with the State.
1259675749 2009-12-01 Production Wells Violations Noted Upon inspecting site at request from supervisor found well producing for domestic purposes only,owner is currently operating without proper bonding,and there is no I.D. at well.
1260487167 2009-12-10 Production Wells Violations Noted No change in status of well ,owner is operating well without proper bonding.
1287442122 2010-10-18 Production Wells No Violations Well is being used for domestic purposes only at this time, and owner is currently operating well without proper bonding and insurance.
1289254013 2010-11-08 Production Wells No Violations Follow Up Inspection to Chiefs Order#2010-41 and inspection revealed that there has been no change in status of well. Owner is still operating wells without proper bonding and insurance.
130536254 2009-12-1 0:00: PW No Violations
1352329388 2012-11-07 Production Wells No Violations Inspection revealed that well is being used for domestic purposes only at this time, according to division records owner is operating well without proper bonding and insurance.
1357353285 2008-04-21 Production Wells No Violations STILL BEING USED FOR HOUSE GAS.
1553083257 2019-03-20 Production Wells No Violations The purpose of my inspection was a follow up on Chiefs Order numbered 2014-135. The order was sent to Ava Gas Corporation as a notice of material and substantial violation for failure to maintain liability insurance. Also following up on Chiefs Order numbered 2017-338. The order was sent to Ava Gas Corporation as a notice of material and substantial violation for failure to file annual statement of production which is in violation of Ohio Revised Code 1509.11. The year 2013 was the last year any production records were submitted when Ava Gas Corporation submitted reports of zero production. Also following up on compliance notice numbered 1259675749. The well was equipped with 4.5-inch diameter casing and a 4.5-inch by 2-inch diameter swage nipple. A domestic gas line was attached with a closed valve. Before the closed valve a gauge was present with 240 pounds per square inch. No other lines were attached. A disconnected horizontal separator was located by the well situated within a thick under brush in the edge of the woods.
1662673044 2020-3-24 0:00: PW No Violations 1.00
192041510 2008-10-3 0:00: PW No Violations
2052995591 2015-06-16 Production Wells No Violations On the day of my inspection following up on NOV-1259675749, I witnessed there was no change in the status of the well and it was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with the valve open providing domestic gas service. Production equipment included a disconnected horizontal separator and no salesline with identification present at the time of inspection.
2055870203 2016-03-29 Production Wells No Violations On the day of my inspection following up on NOV-1259675749, I witnessed there was no change in the status of the well and it was equipped with 8.625 inch casing and 4.5 inch casing reduced to 2 inches with the valve open providing domestic gas service. Gauge present on the casing read 220psi with identification present at the time of inspection. Production equipment included a disconnected horizontal separator.
2085783978 2008-02-28 Production Wells Violations Noted INSPECTION REVEALED WELL IS IDLE. DOES NOT APPEAR TO BE IN PRODUCTION AT THIS TIME. NO DOMESTIC HOOK UP CAN BE SEEN AT WELLHEAD.
289383195 2012-11-7 0:00: PW No Violations 1.00
302824357 2017-2-1 0:00:0 PW No Violations 1.00
494968738 2015-7-13 0:00: PW No Violations 5.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0542307330 US-OH-125944 2008-02-28 Well shall be plugged
1259675749 US-OH-106997 2009-12-01 Failure to legibly identify well
1259675749 US-OH-106998 2009-12-01 Failure to register/obtain or maintain bond/insurance
1260487167 US-OH-107013 2009-12-01 Failure to legibly identify well
1260487167 US-OH-107014 2009-12-01 Failure to register/obtain or maintain bond/insurance
2085783978 US-OH-121292 2008-02-28 Well shall be plugged

For data sources see[9]

References